3.3.7 Refractory Replacement
The intense heat of the fire will normally cause hairline cracks in the refractory. These cracks can be minimized by proper curing as described in "First Fires". They will not normally diminish the effectiveness of the refractory. If large cracks develop, then the refractory should be replaced. To replace the refractory bricks, follow these steps:
1.Remove the front refractories
2.Remove the bottom refractory
3. Remove the left side refractory
4. Remove the right side refractory
5. Remove the back refractory
6. Remove the front ceramic baffle
7. Remove the rear ceramic baffle
To install the new refractories, follow the above steps in reverse.
Figure 2
3.3.8 Door Installation
The door must be installed only when the installation of the BRENTWOOD is completed. All you have to do is fit the male part of the hinge, already on the door, to the female part, which is on the fireplace.
To remove the door, simply pull the door up from the hinges.
The door adjustment has been set at the factory. If the fit is still not perfect, you can adjust the door using the hinge screws.
Figure 3
10