Graco 223596 Service, Disconnecting the Displacement Pump, Reconnecting the Displacement Pump

Page 11

Service

Disconnecting the Displacement Pump

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

1.Flush the pump if possible. Stop the pump at the bottom of its stroke. Relieve the pressure.

2.Disconnect the air and fluid hoses. Remove the pump from its mounting. Note the relative position of the fluid outlet (R) to the air inlet (S). See Fig. 3.

3.Unscrew the tie rod locknuts (4) from the tie rods (10). Remove the cotter pin (3). Carefully pull the displacement pump (13) off the air motor (12).

Unscrew the displacement rod (103) from the air motor (12) or adapter (5, President Pump only). Inspect the o-ring (6).

4.Refer to page 12 for displacement pump service. To service the air motor, refer to the separate air motor manual, which is supplied.

Reconnecting the Displacement Pump

1.Lubricate the o-ring (6) and check that it is in place on the displacement rod (103).

2.Orient the fluid outlet (R) to the air inlet (S) as noted in step 2 under Disconnecting the Displacement Pump. Position the displacement pump (13) on the tie rods (10). See Fig. 3.

3.Screw the displacement rod (103) into the shaft of the air motor (12) or the adapter (5, President Pump only) until the pin holes are aligned. Screw the locknuts (4) onto the tie rods (10) loosely. Install the cotter pin (3).

4.Mount the pump and reconnect all hoses. Reconnect the ground wire if it was disconnected during repair. Torque the packing nut (104) to 18 to 20 ft-lb (24 to 27 N.m). Fill the wet-cup with Graco Throat Seal Liquid or compatible solvent.

5.Tighten the tie rod locknuts (4) evenly, and torque as specified in Fig. 3. Start the pump and run it at about 40 psi (0.28 MPa, 2.8 bar) air pressure, to check that it is operating properly.

Monark Models 223596 (shown) and 237958

1 6

103

4 104

R

1Lubricate.

2Torque to 10 to15 ft-lb (14 to 20 N.m).

3Torque to 20 to 30 ft-lb (27 to 41 N.m).

4Torque to 18 to 20 ft-lb (24 to 27 N.m).

S

President Model 239140 (shown)

12

5

3

102

103

3

4 104

42

R

13

S

12

103

61

43

13

02099

06938

Fig. 3

307619 11

Image 11
Contents Part No , Series a 461 Ratio Presidentr Pump Instructions-Parts ListImportant Safety Instructions Part No , Series B 231 Ratio Monarkr PumpTable of Contents Skin Injection Hazard Fire and Explosion Hazard Grounding InstallationPrepare the Operator Prepare the Site KEY Typical InstallationSystem Accessories Flush the Pump Before First Use Pressure Relief ProcedureStarting and Adjusting the Pump OperationExplosion Hazard on Shutdown and Care of the PumpFlushing the Pump Problem Cause Solution TroubleshootingReconnecting the Displacement Pump ServiceDisconnecting the Displacement Pump Reassembling Displacement Pump ServiceDisassembling Detail B Piston Packings Detail a Throat PackingsModel 237958, Series B Ratio SST Monarkr Pump PartsModel 223596, Series B Ratio CST Monarkr Pump shown Packing NUT/WET-CUP, CST Model 223595, Series DIncludes items 3, 4, 5, 6, 10, 12, Model 239140, Series a Ratio SST Presidentr PumpPacking NUT/WET-CUP Model 239145, Series aPTFE/Leather Conversion Kit Conversion KitsPtfe Conversion Kit Model 223596 shown Dimensions Mounting HoleModel Dimension 223596 237958 239140 LayoutInput Air Pressures at 15 cycles per minute Technical DataSound Power Levels dBa Monark 231 Fluid Outlet Pressure Monark 231 Air Consumption Model 223596 231 Ratio CST Monark Performance ChartModel 237958 231 Ratio SST Monark Performance Chart Page Models 239140 461 Ratio SST President Performance Chart Graco Information Graco Standard Warranty