Graco 239140 important safety instructions Model 223596 231 Ratio CST Monark Performance Chart

Page 21

Technical Data

Model 223596 23:1 Ratio CST Monark Performance Chart

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):

1.Locate desired flow along bottom of chart.

2.Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale to read fluid outlet pressure.

To find Pump Air Consumption (m#/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):

1.Locate desired flow along bottom of chart.

2.Read vertical line up to intersection with selected air consumption curve (dashes). Follow left to scale to read air consumption.

A120 psi (0.8 MPa, 8 bar) air pressure

B70 psi (0.49 MPa, 4.9 bar) air pressure

C40 psi (0.28 MPa, 2.8 bar) air pressure

 

Monark 23:1 Fluid Outlet Pressure

 

Monark 23:1 Air Consumption

 

psi

 

cycles per minute

 

 

scfm

 

cycles per minute

 

 

MPa, bar

15

30

45

60

75

m#/min

15

30

45

60

75

 

 

 

3000

 

 

 

 

 

 

16

 

 

 

 

 

PRESSUREFLUID

21, 210

A

 

 

 

 

CONSUMPTIONAIR

0.45

 

 

 

 

A

2250

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15.8, 158

 

 

 

 

 

 

0.34

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500

B

 

 

 

 

 

8

 

 

 

 

 

 

10.4,104

 

 

 

 

 

 

0.22

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

750

C

 

 

 

 

 

4

 

 

 

 

 

 

5.1, 51

 

 

 

 

 

.011

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

0

 

 

 

 

 

 

gpm 0.0

0.1

0.2

0.3

0.4

0.5

 

gpm 0.0

0.1

0.2

0.3

0.4

0.5

liters/minute

0.4

0.8

1.2

1.5

1.9

liters/minute

0.4

0.8

1.2

1.5

1.9

 

FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)

 

FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)

Model 237958 23:1 Ratio SST Monark Performance Chart

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (lpm/gpm) and operating air pressure (psi/MPa/bar):

1.Locate desired flow along bottom of chart.

2.Follow vertical line up to intersection with selected fluid outlet pressure curve (black). Follow left to scale to read fluid outlet pressure.

To find Pump Air Consumption (m#/min or scfm) at a specific fluid flow (lpm/gpm) and air pressure (psi/MPa/bar):

1.Locate desired flow along bottom of chart.

2.Read vertical line up to intersection with selected air consumption curve (dashes). Follow left to scale to read air consumption.

A150 psi (1.0 MPa, 10 bar) air pressure

B70 psi (0.49 MPa, 4.9 bar) air pressure

C40 psi (0.28 MPa, 2.8 bar) air pressure

 

Monark 23:1 Fluid Outlet Pressure

 

Monark 23:1 Air Consumption

 

psi

 

cycles per minute

 

 

scfm

 

cycles per minute

 

 

MPa, bar

15

30

45

60

75

m#/min

15

30

45

60

75

 

 

 

3500

A

 

 

 

 

 

16

 

 

 

 

 

PRESSUREFLUID

24.5, 245

 

 

 

 

CONSUMPTIONAIR

0.45

 

 

 

 

 

3000

 

 

 

 

 

 

 

 

 

 

A

 

21, 210

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

2500

 

 

 

 

 

 

0.34

 

 

 

 

 

 

17.5, 175

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

2000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14, 140

 

 

 

 

 

 

8

 

 

 

 

 

 

1500

B

 

 

 

 

 

0.22

 

 

 

 

 

 

10.5, 105

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

7,70

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.011

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

 

3.5, 35

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

0

 

 

 

 

 

 

gpm 0.0

0.1

0.2

0.3

0.4

0.5

 

gpm 0.0

0.1

0.2

0.3

0.4

0.5

liters/minute

0.4

0.8

1.2

1.5

1.9

liters/minute

0.4

0.8

1.2

1.5

1.9

 

FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)

 

FLUID FLOW (TEST FLUID: NO. 10 WEIGHT OIL)

307619 21

Image 21
Contents Important Safety Instructions Instructions-Parts ListPart No , Series B 231 Ratio Monarkr Pump Part No , Series a 461 Ratio Presidentr PumpTable of Contents Skin Injection Hazard Fire and Explosion Hazard Installation Prepare the Operator Prepare the SiteGrounding KEY Typical InstallationSystem Accessories Starting and Adjusting the Pump Pressure Relief ProcedureOperation Flush the Pump Before First UseShutdown and Care of the Pump Flushing the PumpExplosion Hazard on Problem Cause Solution TroubleshootingService Disconnecting the Displacement PumpReconnecting the Displacement Pump Displacement Pump Service DisassemblingReassembling Detail B Piston Packings Detail a Throat PackingsParts Model 223596, Series B Ratio CST Monarkr Pump shownModel 237958, Series B Ratio SST Monarkr Pump Packing NUT/WET-CUP, CST Model 223595, Series DIncludes items 3, 4, 5, 6, 10, 12, Model 239140, Series a Ratio SST Presidentr PumpPacking NUT/WET-CUP Model 239145, Series aConversion Kits Ptfe Conversion KitPTFE/Leather Conversion Kit Model Dimension 223596 237958 239140 Dimensions Mounting HoleLayout Model 223596 shownTechnical Data Sound Power Levels dBaInput Air Pressures at 15 cycles per minute Model 223596 231 Ratio CST Monark Performance Chart Model 237958 231 Ratio SST Monark Performance ChartMonark 231 Fluid Outlet Pressure Monark 231 Air Consumption Page Models 239140 461 Ratio SST President Performance Chart Graco Information Graco Standard Warranty