Belkin ST6125D, ST4125D manual Manual-Off-Auto SW. Manual Position, Reset

Page 19

ControlBoxSetup

1.From the voltage source set the circuit breaker or quick disconnect switch to the ON position.

2.For manual operation of the pump, place the 3-position operation switch (Figure 9) on the control box in the MANUAL position.

Figure 9. Manual-Off-Auto SW. (Manual Position)

3.Verify that the ON indicator (Figure 10) on the control box is LIT.This means that power is being supplied to the control box.

Figure 10. Control Box Power ON Indicator

4.In the manual mode the pump will run continuously. Pay close attention when running the pump in this mode. DAMAGE to the pump may occur if pump is not immersed in water.

5.To operate the pump automatically (float switches), place the 3-position operation switch in the AUTO position (Figure 11).

Figure 11. Manual-Off-Auto SW. (Auto Position)

6.In the AUTO mode the pump will run as long as there is a sufficient amount of water.This amount is determined by the setting of the float switches. The stop float switch contacts will open when the water level is low and power will be removed from the pump's motor.

Once the water level has risen back to the appropriate level the start float switch contacts will close and power will be restored to the pump's motor.

ST-4125D/ST-6125D — SETUP

Reset

1.When the overload module detects an overload, the unit will shut down. Check the unit and remove cause of overload.

2.Let the unit cool down and press the RESET button (see Figure 12) on the front of the control box to reset the unit (restore power).

Figure 12. RESET Button

Shut-Down

1.Place the 3-position operation switch on the control box to the OFF position (Figure 13).

Figure 13. Manual-Off-Auto SW. (OFF Position)

2.Verify that the control box power ON light is OFF.

3.Turn the circuit breaker or quick disconnect switch to the OFF position.

ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 19

Image 19
Contents Submersible Pumps Model ST4125D Model ST6125D ST-4125D/ST-6125D Table of Contents Best Deal! Order via Internet Dealers Only Parts Ordering ProceduresOrder via Fax Dealers Only Page Foryour Safety and the Safety of Others ST-4125D/ST-6125D Safety Message Alert SymbolsST-4125D/ST-6125D Rules for Safe Operation General SafetyST-4125D/ST-6125D Rules for Safe Operation Maintenance SafetyEmergencies ST-4125D/ST-6125D Dimensions Specifications ST-4125D/ST-6125D SpecificationsST-4125D/ST-6125D General Information ST-6125D ST-4125D/ST-6125D Submersible Pump ComponentsFloat Switch Theory ST-4125D/ST-6125D Float SwitchesThermal ST-4125D/ST-6125D Control BoxesPhase Power Installation Input ST-4125D/ST-6125D Control BOX Installation230/460VACVoltage Selection ST-4125D/ST-6125D 230/460 VAC Voltage Selection Control Box Wiring Diagram ST-4125D/ST-6125D Control Boxwiring DiagramPersonnel ST-4125D/ST-6125D 3-PHASE Power InstallationThree Phase Control Box/Pump System Diagram ST-4125D/ST-6125D 3-PHASE Power InstallationManual-Off-Auto SW. Manual Position ResetOperation ST-4125D/ST-6125D OperationST-4125D/ST-6125D Operation Pump Shut-Down/Clean-upST-4125D/ST-6125D Maintenance Pump Troubleshooting ST-4125D/ST-6125D -TROUBLESHOOTINGPump Performance Curves ST-4125D/ST-6125D Performance CurvesPage QTY. Column Explanation of Code in Remarks ColumnNO. Column Part NO. ColumnSubmersible Pump 1 to 3 Units ST-4125D/ST-6125D Suggested Spare PartsST-4125D Submersible Pump Assy Remarks ST-4125D Submersible Pump AssyST-6125D Submersible Pump Assy ST-6125D Submersible Pump AssyCABLE, POWER, 24 MM ST-6125D Submersible Pump Assy Thermal Sensor Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help