Belkin ST4125D, ST6125D manual ST-4125D/ST-6125D Rules for Safe Operation, General Safety

Page 6

ST-4125D/ST-6125D RULES FOR SAFE OPERATION

WARNING - ReadThis Manual

Failure to follow instructions in this manual may lead to serious injury or even death! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only.

The following safety guidelines should always be used when operating the ST-4125D/ST-6125D Submersible Pump:

GENERAL SAFETY

DO NOT operate or service this equipment before reading this entire manual.

This equipment should not be operated by persons under 18 years of age.

NEVER operate this equipment without proper protective clothing, shatterproof glasses, steel-toed boots and other protective devices required by the job.

NEVER operate this equipment when not feeling

well due to fatigue, illness or taking medicine.

NEVER operate this equipment under the influence or drugs or alcohol.

NEVER use accessories or attachments, which are not recommended by Multiquip for this equipment. Damage to the equipment and/or injury to user may result.

Manufacturer does not assume responsibility for any accident due to equipment modifications.

Whenever necessary, replace nameplate, operation and safety decals when they become difficult read.

ALWAYS check the machine for loosened threads or bolts before starting.

NEVER operate the submersible pump in an explosive atmosphere or near combustible materials. An explosion or fire could result causing severe bodily harm or even death.

ALWAYS make sure submersible pump is grounded.

NEVER use gas piping as an electrical ground.

DO NOT place hands or fingers inside pump when pump is running.

ALWAYS make certain that the voltage supplied to the pump is correct. Always read the pump's nameplate to determine what the power requirements are. The ST-4125D and ST-6125D submersible pumps require 230 or 460 VAC (three-phase) for normal operation.

DO NOT restrict the flow of the discharge hose as it may cause overheating.

Be careful of discharge whipping under pressure.

Make sure pump installation is in accordance with national and local electrical codes.

ALWAYS have a qualified electrician perform the pump wiring installation.

ALWAYS mount the control box in a vertical position protected from the elements.

NEVER handle pump's AC power cord with wet hands.

NEVER let an extension cord or plug connection lay in water.

NEVER stand in water while AC power cord is connected to a power source.

NEVER use a pump with a defective, frayed power cord. Check the power cord on the pump for cuts in the insulation.

NEVER use a extension cord that is frayed or damaged where the insulation has been cut.

ALWAYS make certain that proper extension cord has been selected for the job.

NEVER attempt to use the power cord as a lifting or lowering device for the submersible pump.

When raising or lowering of the submersible pump is required, always attach an adequate rope or lifting device to the correct lifting point (handle) on the pump.

ALWAYS place the pump in an upright position on a platform before using. The platform will prevent the pump from burrowing itself on soft sand or mud.

NEVER operate pump on its side.

DO NOT allow the pump to freeze in water.

NEVER leave an open pump chamber unattended.

The electrical voltage required to operate the pump can cause severe injury or even death through physical contact with live circuits. ALWAYS disconnect the electrical power from the pump before performing maintenance on the pump.

ALWAYS make sure that electrical circuits are properly grounded per the National Electrical Code (NEC) and

PAGE 6 — ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08)

Image 6
Contents Submersible Pumps Model ST4125D Model ST6125D ST-4125D/ST-6125D Table of Contents Parts Ordering Procedures Best Deal! Order via Internet Dealers OnlyOrder via Fax Dealers Only Page ST-4125D/ST-6125D Safety Message Alert Symbols Foryour Safety and the Safety of OthersGeneral Safety ST-4125D/ST-6125D Rules for Safe OperationMaintenance Safety ST-4125D/ST-6125D Rules for Safe OperationEmergencies ST-4125D/ST-6125D Dimensions ST-4125D/ST-6125D Specifications SpecificationsST-4125D/ST-6125D General Information ST-4125D/ST-6125D Submersible Pump Components ST-6125DST-4125D/ST-6125D Float Switches Float Switch TheoryST-4125D/ST-6125D Control Boxes ThermalST-4125D/ST-6125D Control BOX Installation Phase Power Installation InputST-4125D/ST-6125D 230/460 VAC Voltage Selection 230/460VACVoltage SelectionST-4125D/ST-6125D Control Boxwiring Diagram Control Box Wiring DiagramST-4125D/ST-6125D 3-PHASE Power Installation PersonnelST-4125D/ST-6125D 3-PHASE Power Installation Three Phase Control Box/Pump System DiagramReset Manual-Off-Auto SW. Manual PositionST-4125D/ST-6125D Operation OperationPump Shut-Down/Clean-up ST-4125D/ST-6125D OperationST-4125D/ST-6125D Maintenance ST-4125D/ST-6125D -TROUBLESHOOTING Pump TroubleshootingST-4125D/ST-6125D Performance Curves Pump Performance CurvesPage Part NO. Column Explanation of Code in Remarks ColumnNO. Column QTY. ColumnST-4125D/ST-6125D Suggested Spare Parts Submersible Pump 1 to 3 UnitsST-4125D Submersible Pump Assy ST-4125D Submersible Pump Assy RemarksST-6125D Submersible Pump Assy ST-6125D Submersible Pump AssyCABLE, POWER, 24 MM ST-6125D Submersible Pump Assy Thermal Sensor Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help

ST6125D, ST4125D specifications

Belkin is renowned for producing high-quality networking and connectivity solutions, and their ST4125D and ST6125D models exemplify this commitment. The ST4125D is a 4-port USB hub, while the ST6125D serves as a versatile 6-port USB hub, both designed to enhance productivity and connectivity for users, especially in environments where multiple devices are used simultaneously.

One of the main features of the Belkin ST4125D and ST6125D is their ability to expand USB connectivity effortlessly. Each hub allows users to connect multiple devices to a single USB port, which is particularly useful for laptops and desktops that have limited ports. The ST4125D features four USB 3.0 ports, while the ST6125D includes six, making them perfect for connecting printers, external hard drives, and other peripherals without having to switch devices.

Another significant technology integrated into both models is USB 3.0, which offers data transfer speeds of up to 5 Gbps. This high-speed performance not only ensures rapid file transfers but also improves efficiency when moving large volumes of data. The backward compatibility with USB 2.0 devices also ensures that users can connect older peripherals without any issues, making these hubs highly versatile.

The design of the ST4125D and ST6125D hubs promotes convenience and ease of use. Their compact and lightweight form factor makes them portable, ideal for both home and office environments. Additionally, the hubs feature individual power switches for each port, granting users control over power management and enhancing energy efficiency.

Furthermore, both models boast an LED indicator for power status, providing real-time feedback to users. They also come equipped with a sturdy build quality, ensuring longevity and durability even with regular use. With plug-and-play functionality, setting up the hubs is hassle-free, requiring no additional drivers or software installation.

In conclusion, both the Belkin ST4125D and ST6125D USB hubs present excellent solutions for anyone seeking enhanced connectivity options. With their combination of speed, functionality, and user-friendly features, they are a valuable asset in today’s increasingly device-driven world. Whether for personal use, home offices, or larger business settings, these hubs stand out as reliable tools that meet diverse connectivity needs effectively.