Belkin ST6125D, ST4125D manual ST-4125D/ST-6125D Submersible Pump Components

Page 11

ST-4125D/ST-6125D SUBMERSIBLE PUMP COMPONENTS

5

 

 

6

6

5

4

 

 

 

 

 

4

 

3

3

 

ST-4125D

 

ST-6125D

SUBMERSIBLE

 

SUBMERSIBLE

PUMP

 

PUMP

2

 

2

1

7

1

ST-4125D

8

ST-6125D

 

Figure 2. Submersible Pump Components

7

8

Figure 2 shows the location of the basic components, for the ST-4125D and ST-6125D submersible pumps.Listed below is a brief explanation of each component.

1.Strainer Base – This strainer base is made of stainless steel which is resistant to hardware corrosion. For dewatering purposes, always place the strainer base on a platform.

2.Volute/Impeller – Impellers are constructed of cast ductile iron to minimize wear and prolong service life.

3.Electric Motor – The ST-4125D pump utilizes a 60 Hz, three-phase, 230/460 VAC, 10 HP electric motor and the ST-6125D pump utilizes a 60 Hz, three-phase, 230/ 460 VAC, 15 HP electric motor. Consult with a licensed electrician before connecting motor to a power source. Observe all city and local safety codes.

4.Discharge Port – Connect a 4-inch hose (ST-4125D) or 6-inch hose (ST-6125D) to this port. Remember to adequately support the discharge hose to avoid stress on the pump.

5. AC Power Cable – These pumps are supplied with a 50 ft. (15.2 meters) AC power cable. Always check the cable for signs of wear. NEVER use a defective power cable. Replace the cable immediately if the cable is worn or defective.

6.Eye Bolts – Always lift the submersible pump by the eye bolts using a chain and lifting device capable of lifting about 400 lbs. NEVER lift the pump by its power cord! Lifting the pump by the power cord will cause undue stress on the cord and ultimately the cord will become dislodged from the pump.

7.Mechanical Seal Oil – This oil-filled seal provides lubrication when running the pump dry. NEVER run the pump dry! Running the pump dry will cause severe damage to the pump.

8.Mechanical Seal Oil Plug – Remove this plug to check and add hydraulic oil (Shell 32 or equivalent) to the oil cavity. This oil protects the mechanical seal. Oil cavity should be full enough to cover seal spring.

ST-4125D/ST-6125D SUBMERSIBLE PUMPS — OPERATION AND PARTS MANUAL — REV. #1 (06/12/08) — PAGE 11

Image 11
Contents Submersible Pumps Model ST4125D Model ST6125D ST-4125D/ST-6125D Table of Contents Order via Fax Dealers Only Parts Ordering ProceduresBest Deal! Order via Internet Dealers Only Page Foryour Safety and the Safety of Others ST-4125D/ST-6125D Safety Message Alert SymbolsST-4125D/ST-6125D Rules for Safe Operation General SafetyEmergencies Maintenance SafetyST-4125D/ST-6125D Rules for Safe Operation ST-4125D/ST-6125D Dimensions Specifications ST-4125D/ST-6125D SpecificationsST-4125D/ST-6125D General Information ST-6125D ST-4125D/ST-6125D Submersible Pump ComponentsFloat Switch Theory ST-4125D/ST-6125D Float SwitchesThermal ST-4125D/ST-6125D Control BoxesPhase Power Installation Input ST-4125D/ST-6125D Control BOX Installation230/460VACVoltage Selection ST-4125D/ST-6125D 230/460 VAC Voltage SelectionControl Box Wiring Diagram ST-4125D/ST-6125D Control Boxwiring DiagramPersonnel ST-4125D/ST-6125D 3-PHASE Power InstallationThree Phase Control Box/Pump System Diagram ST-4125D/ST-6125D 3-PHASE Power InstallationManual-Off-Auto SW. Manual Position ResetOperation ST-4125D/ST-6125D OperationST-4125D/ST-6125D Operation Pump Shut-Down/Clean-upST-4125D/ST-6125D Maintenance Pump Troubleshooting ST-4125D/ST-6125D -TROUBLESHOOTINGPump Performance Curves ST-4125D/ST-6125D Performance CurvesPage QTY. Column Explanation of Code in Remarks ColumnNO. Column Part NO. ColumnSubmersible Pump 1 to 3 Units ST-4125D/ST-6125D Suggested Spare PartsST-4125D Submersible Pump Assy Remarks ST-4125D Submersible Pump AssyST-6125D Submersible Pump Assy ST-6125D Submersible Pump AssyCABLE, POWER, 24 MM ST-6125D Submersible Pump Assy Thermal Sensor Freight Policy Terms and Conditions of Sale PartsPage HERE’S HOW to GET Help