Desa S39PT installation manual Nance

Page 17

OWNER’S MANUAL

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1.

Burner orifice clogged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 15) or replace burner orifice

 

2.

Inlet gas pressure is too low

2.

Contact local propane/LP gas company

 

3.

Burner orifice diameter is too small

3.

Replace burner orifice

 

4.

Thermopile leads disconnected or im-

4.

Reconnect leads (see wiring diagram)

 

 

properly connected

 

 

 

5. Burners will not come on in remote position

5.

Replace battery in transmitter and receiver

 

 

 

 

 

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local propane/LP gas company

 

2.

Burner orifice clogged

2.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 15) or replace burner orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 15) or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas control

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Not enough air

1.

Check burner for dirt and debris. If found,

 

 

 

 

clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 15)

 

2.

Gas regulator defective

2.

Replace gas control

 

3.

Residues from manufacturing processes

3.

Problem will stop after a few hours of

 

 

and logs curing

 

operation

 

 

 

 

 

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Ventila-

 

 

 

 

tion requirements (page 4)

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position when

1.

Turn control knob to LO position and let

burner is lit

 

burner is cold

 

warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas line checked by local pro-

 

 

 

 

pane/LP gas company

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clearances

 

 

 

 

(see pages 7 through 9)

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 15) or replace burner orifice

 

 

 

 

 

Dark residue on logs or inside of fireplace

1.

Improper log placement

1.

Properly locate logs (see Installing Logs,

 

 

 

 

page 10)

 

2.

Drafts or other air currents affecting

2.

Eliminate source of drafts around heater

 

 

flame pattern

 

 

 

3.

Air holes at burner inlet blocked

3.

Clean out air holes at burner inlet. Peri-

 

 

 

 

odically repeat as needed

 

4.

Burner flame holes blocked

4.

Remove blockage or replace burner

 

 

 

 

 

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. turn into white powder residue

1.Turn heater off when using furniture pol- ish, wax, carpet cleaners, or similar products

www.desatech.com

Continued

 

 

107435

17

For more information, visit www.desatech.com

Image 17
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualVENT-FREE PROPANE/LP Pedestal Stove Safety InformationSafety Pilot Product FeaturesProduct Identification Local Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationClearances to Combustibles Minimum Wall and Ceiling Clearances see FigureInstallation Items Needed Connecting to GAS SupplyChecking GAS Connections Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System Installing Optional Blower Accessory GA3750 Installing LogsKnob Housing Installing Optional Blower Accessory GA3650TARemoving Cover Plate Lighting Instructions For Your Safety Read Before LightingOperating Heater Inspecting Burners Cleaning and Maintenance Observed Problem Possible Cause Remedy TroubleshootingNance, Top Service Hints SpecificationsTechnical Service Parts CentralsS39PT Illustrated Parts BreakdownKEY Part Number Description QTY Parts List2611 KEY Description QTY Accessories Replacement Parts107435 International Warranty Information