Desa S39PT installation manual Top

Page 18

VENT-FREE PROPANE/LP PEDESTAL STOVE

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Open window and ventilate room. Stop using odor causing products while heater is running

2.Locate and correct all leaks (see Check- ing Gas Connections, page 9)

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

 

2.

Low line pressure

 

3.

ODS/pilot is partially clogged

1.Open window and/or door for ventilation

2.Contact local propane/LP gas company

3.Clean ODS/pilot (see Cleaning and Maintenance, page 15)

Gas odor even when control knob is in OFF position

1.Gas leak. See Warning statement at top of page

2.Control valve defective

1.Locate and correct all leaks (see Check- ing Gas Connections, page 9)

2.Replace control valve

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 9)

Burner flame is excessively large and is

1.

Excessive line or manifold pressure

very near or touches the top of firebox

2.

Dirty primary air holes

 

1.Check manifold pressure and correct as needed

2.Clean burner air holes (see Cleaning and Maintenance, page15)

www.desatech.com

For more information, visit www.desatech.com

18

107435

Image 18
Contents OWNER’S Operation and Installation Manual What to do if YOU Smell GASSafety Information VENT-FREE PROPANE/LP Pedestal StoveProduct Identification Local Codes Product FeaturesSafety Pilot UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Clearances to Combustibles InstallationCheck GAS Type Minimum Wall and Ceiling Clearances see FigureConnecting to GAS Supply Installation Items NeededPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Logs Installing Optional Blower Accessory GA3750Installing Optional Blower Accessory GA3650TA Knob HousingRemoving Cover Plate For Your Safety Read Before Lighting Operating HeaterLighting Instructions Inspecting Burners Cleaning and Maintenance Troubleshooting Observed Problem Possible Cause RemedyNance, Top Technical Service SpecificationsService Hints Parts CentralsIllustrated Parts Breakdown S39PTParts List KEY Part Number Description QTY2611 KEY Description QTY Replacement Parts Accessories107435 Warranty Information International