Desa (F)SVYD18NR installation manual Touch-up Paint Bottle with Brush Porcelain Enamel Teal Green

Page 27

OWNER’S MANUAL

PARTS LIST

AMITY™ SCIVF(*) SERIES PSCIVF(*) SERIES

(* Indicates Color Suffix Designation)

Note: Your stove may have a three-piece removable top grate or a one-piece remov- able top grate depending on model.

This list contains replaceable parts used in your stove. When ordering parts, follow the instructions listed under Replacement Parts on page 32 of this manual.

KEY

PART

 

 

NO.

NO.

DESCRIPTION

QTY.

 

 

 

 

1

104171-01

One-Piece Top Grate with Screen (Black Only)

1

1L

104171-11

Top Grate with Screen - Left (Black Only)

1

1C

104171-08

Top Grate with Screen - Center (Black Only)

1

1R

104171-12

Top Grate with Screen - Right (Black Only)

1

2

104172-01

Stove Back Panel (Black Only)

1

3

104173-01

Bottom Door (Charcoal)

1

 

104173-02

Bottom Door (Azure Blue)

1

 

104173-03

Bottom Door (Hunter Green)

1

 

104173-04

Bottom Door (Burgundy Red)

1

 

104173-05

Bottom Door (Forest Green)

1

 

104173-06

Bottom Door (Metallic Charcoal)

1

 

104173-07

Bottom Door (Porcelain Enamel Red)

1

 

104173-08

Bottom Door (Porcelain Enamel Teal Green)

1

 

104173-09

Bottom Door (Porcelain Enamel Sand)

1

4

104174-01

Stove Dropped Bottom

1

5

104175-01

One Leg (Charcoal) (4 Total Per Stove)

1

 

104175-02

One Leg (Azure Blue) (4 Total Per Stove)

1

 

104175-03

One Leg (Hunter Green) (4 Total Per Stove)

1

 

104175-04

One Leg (Burgundy Red) (4 Total Per Stove)

1

 

104175-05

One Leg (Forest Green) (4 Total Per Stove)

1

 

104175-06

One Leg (Metallic Charcoal) (4 Total Per Stove)

1

 

104175-07

One Leg (Porcelain Enamel Red) (4 Total Per Stove)

1

 

104175-08

One Leg (Porcelain Enamel Teal Green) (4 Total Per Stove)

1

 

104175-09

One Leg (Porcelain Enamel Sand) (4 Total Per Stove)

1

6

104176-01

Leg Leveler bolt M8 x 1.25 - 55mm Long (4 Total Per Stove)

1

7

104177-01

Hardware Kit

1

7-1

*

Door Hinge Step Bolt With Shoulder (1 Per Unit)

1

7-2

*

Door Catch Bolt M8 x 1.25 - 55mm Long With Two M8

 

 

 

Hex Nuts (1 Per Unit)

1

7-3

*

Bottom Floor Bolts M6 x 1 - 25mm Long With Flat Washer

 

 

 

And Lock Washer (4 Per Unit)

1

7-4

*

Leg Bolts M6 x 1.25 - 20mm Long With Flat Washer And

 

 

 

Lock Washer (4 Per Unit)

1

8

104178-01

Back Panel Bolts M6 x 1 - 20mm Long With Flat Washer

 

 

 

And Lock Washer (6 Per Unit)

1

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

 

 

 

 

 

104108-01

Touch-up Spray Paint 12 oz Can (Charcoal)

1

 

104108-02

Touch-up Spray Paint 12 oz Can (Azure Blue)

1

 

104108-04

Touch-up Spray Paint 12 oz Can (Burgundy Red)

1

 

104108-05

Touch-up Spray Paint 12 oz Can (Hunter Green)

1

 

104108-06

Touch-up Spray Paint 12 oz Can (Metallic Charcoal)

1

 

104807-01

Touch-up Paint Bottle with Brush (Porcelain Enamel Red)

1

 

104807-02

Touch-up Paint Bottle with Brush (Porcelain Enamel Teal Green)

1

 

104807-03

Touch-up Paint Bottle with Brush (Porcelain Enamel Sand)

1

 

 

 

 

* Included In Hardware Kit

104461

27

Image 27
Contents What to do if YOU Smell GAS VENT-FREE Natural GAS Stove HeaterDesa International VENT-FREE Natural GAS Stove Heater Safety InformationProduct Features Product IdentificationLocal Codes Confined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingVent-Free Operation Only InstallationCheck GAS Type Clearances to CombustiblesUse an adjustable wrench or Stove Cavity AssemblySheraton Models Amity and Townsend ModelsAttaching Stove Door Appearance May Vary Depending on Model Fastening Heater Base to Stove Drop Bottom Installing GAS LOG Heater Into StoveInstallation Items Needed Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections SVYD18NR and FSVYD18NR Remote-Ready Models For Your Safety Read Before LightingOperating Heater Lighting InstructionsManual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation SVYD18N and FSVYD18N Manual-Variable Control Models Variable Control OperationMain Burner Inspecting BurnersPilot Flame Pattern Burner Primary AIR HolesCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceSpecifications Technical ServiceObserved Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Top SVYD18NR FSVYD18NR Illustrated Parts BreakdownKEY Part Number Description QTY Parts ListSVYD18N FSVYD18N KEY Part Description QTY Indicates Color Suffix Designation Amity SCIVF* Series PSCIVF* SeriesTouch-up Paint Bottle with Brush Porcelain Enamel Teal Green Sheraton NSCIVF* Series Parts List Series TownsendFC* and PFC* Series *Indicates Color Suffix Designation Parts Under Warranty Replacement PartsService Hints Wiring DiagramAccessories Warranty Information

(F)SVYD18N, (F)SVYD18NR specifications

Desa (F)SVYD18NR and (F)SVYD18N are advanced models in the range of valves designed to serve various industrial and residential applications. Known for their reliability and efficiency, these valves are engineered to meet the demanding needs of modern fluid control systems.

One of the main features of the Desa (F)SVYD18NR and (F)SVYD18N is their robust construction. They are made from high-quality materials that ensure durability and longevity, even in harsh operating conditions. The valves are resistant to corrosion, making them suitable for handling aggressive fluids without compromising their integrity. This characteristic is essential for industries such as chemicals, oil and gas, and water treatment, where exposure to different substances is inevitable.

The valves are also equipped with advanced sealing technologies which prevent leaks and ensure optimal performance. The precision-engineered seals provide a barrier against contaminants while maintaining efficient fluid flow. This not only enhances the reliability of the system but also contributes to reduced maintenance costs and downtime.

Another significant advantage of the Desa (F)SVYD18NR and (F)SVYD18N is their versatility. They are designed to accommodate a wide range of fluid types, including gases, liquids, and slurries. This adaptability makes them ideal for various applications, from HVAC systems to industrial manufacturing processes.

In terms of operation, these valves utilize a user-friendly design that facilitates ease of installation and adjustment. They come with standardized connections that fit a variety of piping systems, simplifying the integration process. Additionally, the models have a responsive actuator mechanism that ensures precise control over fluid flow, enhancing operational efficiency.

Moreover, Desa (F)SVYD18NR and (F)SVYD18N are designed with energy efficiency in mind. Their advanced aerodynamic design minimizes pressure drops and energy consumption, making them an environmentally friendly choice. This aligns with the growing trend of sustainable practices in industrial operations.

Finally, both models are subject to rigorous testing to ensure they meet industry standards and regulations. This commitment to quality assurance guarantees that users can trust the performance and safety of these valves in their operations.

In conclusion, the Desa (F)SVYD18NR and (F)SVYD18N valves stand out for their durability, versatility, easy installation, and commitment to energy efficiency. These characteristics make them an excellent choice for anyone seeking reliable fluid control solutions in various applications.