Desa (F)SVYD18N Replacement Parts, Service Hints, Wiring Diagram, Parts Under Warranty

Page 32

DESA INTERNATIONAL

VENT-FREE NATURAL GAS STOVE HEATER

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-866-672-6040. When call- ing DESA International, have ready

your name and address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International at 1-866-672-6040 for referral information. When calling DESA International, have ready

model number of your heater

the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

heater will not produce specified heat

You may feel your gas pressure is too low. If so, contact your local natural gas supplier.

WIRING DIAGRAM

(SVYD18NR and FSVYD18NR Series Remote-Ready models only)

Note: For proper operation of optional accessories, the wires from the switch to the control must be connected exactly as shown.

AUTO

OFF

ON

Thermopile

32

104461

Image 32 Contents
VENT-FREE Natural GAS Stove Heater What to do if YOU Smell GASSafety Information Desa International VENT-FREE Natural GAS Stove HeaterLocal Codes Product FeaturesProduct Identification AIR for Combustion and Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From InsideBuilding Ventilation Air From OutdoorsInstallation Check GAS TypeClearances to Combustibles Vent-Free Operation OnlyStove Cavity Assembly Use an adjustable wrench orAmity and Townsend Models Sheraton ModelsAttaching Stove Door Appearance May Vary Depending on Model Installing GAS LOG Heater Into Stove Fastening Heater Base to Stove Drop BottomConnecting to GAS Supply Installation Items NeededChecking GAS Connections Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System For Your Safety Read Before Lighting Operating HeaterLighting Instructions SVYD18NR and FSVYD18NR Remote-Ready ModelsOptional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Variable Control Operation SVYD18N and FSVYD18N Manual-Variable Control ModelsInspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerCleaning and Maintenance SpecificationsTechnical Service Cleaning Burner Injector Holder and Pilot AIR Inlet HoleTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Top Illustrated Parts Breakdown SVYD18NR FSVYD18NRParts List KEY Part Number Description QTYSVYD18N FSVYD18N KEY Part Description QTY Amity SCIVF* Series PSCIVF* Series Indicates Color Suffix DesignationTouch-up Paint Bottle with Brush Porcelain Enamel Teal Green Sheraton NSCIVF* Series Parts List Townsend SeriesFC* and PFC* Series *Indicates Color Suffix Designation Replacement Parts Service HintsWiring Diagram Parts Under WarrantyAccessories Warranty Information