3.5MAINTAINING THE FIRE

Once the wood has been consumed (or partially consumed) and you have obtained a good bed of embers, you should reload the unit. In order to do so, open the air control to its maximum for approximately 15 seconds prior to opening the stove door. Then, proceed by opening the door very slowly. Open it by 2” to 4” (52 to 104 mm) for 10 to 15 seconds before opening it completely. This procedure will increase the draft and thus eliminate the smoke which is stagnant in a state of slow combustion in the stove. Then, bring the red embers to the front of the stove and reload the unit.

Depending on the type of wood you burn and the strength of the draft in your flue, you may have to leave the air control open to its maximum for more than 15 seconds to avoid smoke spillage before you reload the stove.

Your E.P.A Drolet stove will work best if a thick bed of hot embers is maintained in the bottom of the firebox, and a minimum of two large pieces of seasoned fuel are added. Combustion efficiency is largely related to establishing a hot ember bed, and hot firebox temperatures. The quicker the stove and chimney (flue) get up to normal operating temperatures, the better. A small intense fire is preferred to a large smouldering fire, both to improve combustion efficiency and to reduce the amount of creosote build-up. The best performance will be obtained by adding relatively small amounts of fuel to a well established ember bed, and then operating with the air inlet control open long enough to achieve a hot fire. The wood should be placed with air in between individual pieces. Use a poker to make an air channel in the embers below the wood. This will allow air to flow under the wood for a more efficient burn.

In order to achieve an optimum efficiency from your unit, we suggest that you operate it with the air control slightly open (approximately 10%). Make sure that you have a good fire going and an adequate ember bed before you completely close the air control. Use a chimney thermometer if necessary. Closing the air control too soon will lower combustion efficiency and may cause the fire to die out. The addition of a blower (if not already included) is highly recommended to maximize your unit’s efficiency.

3.6FAN (BLOWER) OPERATION

If you have purchased and installed and optional fan (blower), allow the stove to reach operating temperature (approximately one hour), before turning on the fan. The increased airflow from the fan will cool the firebox and affect the start-up combustion efficiency if the fan is turned on too quick.

CAUTION: ENSURE THAT THE FANS POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE TTOVE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE. DO NOT RUN THE POWER CORD BENEATH THE STOVE.

Image 41
Contents Models DB03100, DB03110, DB03115, & DB03116 Escape 1800 EPA Wood StoveIntroduction Table of Contents Specifications Drolet Limited Lifetime Warranty General Installation InstallationLegs and ash drawer assembly for DB03116 model Page See .3 on the following Positioning the StoveClearances Clearances to combustible materials Type of Protection Reduced ClearancesGraphic Graphic Graphic Floor protector Floor ProtectorTips on Wood Heating Chimney Chimney Flue SystemDefinitions Page Stove pipe Wall support systemChimney Typical installation through the wall 1 a Typical installation through the wallPage Page Page Ceiling support system Typical installation through the ceilingPage Page Page 2 a Typical Installation Through an Existing Masonry Chimney 2 B Factory Built Thimble 2 C Brick Thimble Chimney Connector A Connecting Sections Draft Outside Combustion AIR Advantage of Installing a Blower FANPage Keep these instructions for future reference OperationSafety Information Fuel Wood species Energy yield Millions of BTU/cord Energy yield for wood species Use of manufactured logsLighting a Fire Simple wood moisture testIntensity Draft Setting FAN Blower Operation Maintaining the FireGlass MaintenanceCleaning and Painting Your Stove Gasketing ASH Removal Using the ASH DrawerBaffle Installation for Escape 1800 Model Chimney Flue CleaningVermiculite Baffle Front 41 holes of 5/32 Secondary AIR Tube ReplacementImportant Notes Section Specifications Description Drolet Limited Lifetime Warranty