Drolet 1600, 2000, 1200 owner manual Chimney

Page 16

CHIMNEY

Your wood stove may be hooked up with a factory built or masonry chimney. If you are using a factory built chimney, it must comply with UL 103 or ULC S629 standards; therefore it must be a Type HT (2100°F). It is extremely important that it be installed according to the manufacturer's specifications.

If you are using a masonry chimney, it is important that it be built in compliance with the specifications of the National Building Code. It must be lined with fire clay bricks, metal or clay tiles sealed together with fire cement. (Round flues are the most efficient).

The interior diameter of the chimney flues must be identical to the stove's smoke exhaust. A flue which is too small may cause draught problems, while a large flue favours rapid cooling of the gas, and hence the build-up of creosote and the risk of chimney fires. Note that it is the chimney and not the stove which creates the draught effect; your stove's performance is directly dependent on an adequate draught from your chimney.

The following recommendations may be useful for the installation of your chimney:

1.Do not connect this unit to a chimney flue serving another appliance.

2.It must rise above the roof at least 3' (0.9 mm) from the uppermost point of contact.

3.The chimney must exceed any part of the building or other obstruction within a 10' (3.04 m) distance by a height of 2' (0.6 m).

4.Installation of an interior chimney is always preferable to an exterior chimney. Indeed, the interior chimney will, by definition, be hotter than an exterior chimney, being heated up by the ambient air in the house. Therefore the gas which circulates will cool more slowly, thus reducing the build-up of creosote and the risk of chimney fires.

5.The draught caused by the tendency for hot air to rise will be increased with an interior chimney.

6.Using a fire screen at the extremity of the chimney requires regular inspection in order to insure that it is not obstructed thus blocking the draught, and it should be cleaned when necessary.

15

Image 16
Contents SIBERIAN-1200 SIBERIAN-1600 SIBERIAN-2000 Read and Keep this Manual for ReferenceTable of Contents Introduction Technical Specifications SIBERIAN-1200 SIBERIAN-1600 SIBERIAN-2000Assembly Pedestal and Decorative Sidewall InstallationBricks Installation SIBERIAN-1200 SIBERIAN-1200Bricks and Insulation Installation SIBERIAN-1600 SIBERIAN-1600 Refractory Bricks AssemblyBrick and Insulation Installation Siberian Siberian 2000 Refractory Bricks AssemblyAIR Tubes Installation Siberian Air Tubes InstallationDoor Adjustment Door AdjustmentBenefits of Installing a Blower Installation Positioning the StoveFloor Protector Clearances CanadaReduced Clearances Type of ProtectionChimney Chimney Connector Stove Pipe Typical Installations Factory Built ChimneyClay liner Thimble Clean out Door Factory Built Thimble Brick Thimble Woodstove Utilization Average Energy Yield Of One Air Dried Cord Of Cut WoodFirst Fires Testing Your WoodIgnition Heating Low Medium HighReloading Creosote Formation and Need for RemovalASH Disposal Maintenance GlassGasketing PaintLimited Lifetime Warranty Description Warranty Application