Drolet 1200, 2000, 1600 owner manual Chimney Connector Stove Pipe

Page 17

CHIMNEY CONNECTOR (STOVE PIPE)

Your chimney connector and chimney must have the same diameter as the stove outlet. If this is not the case, we recommend you contact your dealer in order to insure there will be no problem with the draught.

The stove pipe must be made of aluminized or cold roll steel with a minimum thickness of 0.021" or 0.53 mm. It is strictly forbidden to use galvanized steel.

Your smoke pipe should be assembled in such a way that the male section of the pipe faces down. Attach each of the sections to one another with three equidistant metal screws.

The pipe must be short and straight. All sections installed horizontally must slope at least 1/4 inch per foot, with the upper end of the section toward the chimney.

To insure a good draught, the total length of the coupling pipe should never exceed 8' to 10' (24 to 3.04 m). (Except for cases of vertical installation, cathedral-roof style where the smoke exhaust system can be much longer and connected without problem to the chimney at the ceiling of the room).

There should never be more than two 90 degrees elbows in the smoke exhaust system.

Installation of a "barometric draught stabiliser" (fireplace register) on a smoke exhaust system is prohibited.

Furthermore, installation of a draught damper is not recommended. Indeed, with a controlled combustion wood stove, the draught is regulated upon intake of the combustion air in the stove and not at the exhaust.

Stove Pipe

16

Image 17
Contents Read and Keep this Manual for Reference SIBERIAN-1200 SIBERIAN-1600 SIBERIAN-2000Table of Contents Introduction SIBERIAN-1200 SIBERIAN-1600 SIBERIAN-2000 Technical SpecificationsPedestal and Decorative Sidewall Installation AssemblySIBERIAN-1200 Bricks Installation SIBERIAN-1200SIBERIAN-1600 Refractory Bricks Assembly Bricks and Insulation Installation SIBERIAN-1600Siberian 2000 Refractory Bricks Assembly Brick and Insulation Installation SiberianAir Tubes Installation AIR Tubes Installation SiberianDoor Adjustment Door AdjustmentBenefits of Installing a Blower Positioning the Stove InstallationFloor Protector Canada ClearancesType of Protection Reduced ClearancesChimney Chimney Connector Stove Pipe Factory Built Chimney Typical InstallationsClay liner Thimble Clean out Door Factory Built Thimble Brick Thimble Average Energy Yield Of One Air Dried Cord Of Cut Wood Woodstove UtilizationIgnition Testing Your WoodFirst Fires Low Medium High HeatingCreosote Formation and Need for Removal ReloadingASH Disposal Glass MaintenanceGasketing PaintDescription Warranty Application Limited Lifetime Warranty