COUPLINGS

10- Next, slide the storm collar down the chimney until it contacts the flashing. Tighten the nut and bolt and seal the collar to the chimney with a waterproof, non-combustible silicone sealant. Finally, twist on your rain cap and you can head back inside. If the chimney extends more than 5 feet above the roof deck, roof guys with telescoping legs and draw bands are required.

11- You are now ready to connect your chimney to your stove. Simply install the inter-connecting stove pipe between the stove pipe adapter and the stove. You can follow the instructions in the following sections of this manual under “COUPLINGS”.

COUPLINGS

It is very important to measure the clearance between your connectors (commonly called stove pipe) and the surrounding combustible surfaces. If the normal 18 inches clearance required cannot be obtained, you may have to use an insulated flue pipe in order to install. You must read the flue pipe manufacturer's instructions before installation.

Your connectors and chimney must have the same diameter as the stove outlet. If this is not the case, we recommend you contact your supplier in order to insure there will be no problem with the draft. Your connectors should be made of aluminized or ordinary steel with a minimum 24 gauge thickness.

Your smoke exhaust system (connectors) should be assembled in such a way that the male section of the pipes faces down. Attach each of the sections to one another with three equidistant metal screws.

The connectors must be short and straight. All sections installed horizontally must slope at least 1/4 inch per foot, with the upper end of the section toward the chimney.

To insure a good draft, the total length of the exhaust system should never exceed 8 to 10 feet. (Except for cases of vertical installations or cathedral-roof, where the smoke exhaust system can be much longer and connected without problem to the chimney at the ceiling level). There should never be more than one 90° elbow in the smoke exhaust system.

Installation of a "barometric draft stabilizer" (fireplace register) on a smoke exhaust system is prohibited.

Furthermore, installation of a draught damper is not recommended. Indeed, with a controlled combustion wood stove, the draught is regulated upon intake of the combustion air in the stove and not at the exhaust.

The connectors must not go through a ceiling, a storage area, a floor, or any other combustible partition.

15

Image 15
Contents 29/08/2005 1700, Léon-Harmel Québec Qc Canada G1N 4R9 Tel FaxWOOD STOVE MANUAL STOVE BUILDER INTERNATIONALTHE DROLET WOOD STOVE MANUAL TABLE OF CONTENTSINSTALLATION OF YOUR DROLET WOOD STOVE BAFFLE BRICK INSTALLATION SAWMAN STOVE ONLYKEEP THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE INTRODUCTION THE DROLET WOOD STOVE MANUALWOOD HEATING THE CONTROLLED COMBUSTION WOOD STOVE4- Bend the heat shield slightly to make it fit between the back legs ASSEMBLING THE STOVE1- Mount the 4 legs using 2 screws per leg 2- Mount the ash lip with two screwsINSTALLING THE FIREBRICKS Models INSTALLATION OF YOUR DROLET WOOD STOVEPOSITIONING THE STOVE FLOOR PROTECTIONBack Wall CLEARANCES TO COMBUSTIBLE MATERIALSCLEARANCES ModelSIDES AND INSTALLATION OF A HEAT RADIATION SHIELDFOR BARON 1880SP & 2000SP USING THE ENVELOPE TYPE OF PROTECTIONChimney STEP BY STEP INSTALLATION OF YOUR CHIMNEYCHIMNEY WALL SUPPORT SYSTEMStove pipe Page CEILING SUPPORT SYSTEM Suitable lengths of stove pipe Page COUPLINGS Page B Floor Connection EXTERIOR AIR INTAKEAIR CIRCULATION SYSTEM A Rear Wall ConnectionBAFFLE BRICK INSTALLATION SAWMAN STOVE ONLY High Energy Yield OPERATING YOUR DROLET WOOD STOVEFUEL AVERAGE ENERGY YIELD OF ONE AIR DRIED CORD OF CUT WOODBefore your first fire IGNITIONHEATING MAINTENANCE OF THE STOVE MAINTENANCE OF THE HEATING SYSTEMCALL IMMEDIATELY THE FIRE DEPARTMENT PROCEDURES IN CASE OF FIREMAINTENANCE OF THE CHIMNEY IN CASE OF FIREWHAT DO THE WORDS “DRAFT” AND “NEGATIVE PRESSURE” MEAN? FREQUENTLY ASKED QUESTIONSDRAWING #1 DRAWING #2 DRAWING #3 DRAWING #4 DRAWING #5 WHEN DO IN NEED TO REPLACE THE FIREBRICKS? CAN I MODIFY MY STOVE TO INSTALL A GLASS DOOR?LABOUR LIMITED LIFETIME WARRANTYWARRANTY APPLICATION PARTS