Once you have obtained a good bed of embers you should reload the unit. In order to do so, open the air control completely for a few seconds prior to opening the stove door. Then, proceed by opening the door very slowly. Open it by one or two inches for 5 to 10 seconds before opening it completely. This will increase the draft and will eliminate the smoke, which is stagnant in a state of slow combustion. Then, bring the red embers to the front of the stove and reload the unit. Use only the quantity of wood required depending on the circumstances; for example, in severe cold weather, load the stove to maximum. During milder temperatures, the stove should be only half loaded. CAUTION : DO NOT PLACE LOGS TOO CLOSE TO

THE GLASS OR THE DOOR. IF LOGS ARE TOO CLOSE TO THE GLASS OR THE DOOR, THEY MAY FALL WHEN YOU OPEN THE DOOR. FURTHERMORE, THE LOGS THAT ARE TOO CLOSE MAY DAMAGE THE GLASS IF YOU SHUT THE DOOR TO HARD.

When possible, we recommend that you operate the stove with a wood load approximately equivalent to the height of the fire bricks. If you constantly load the stove above the fire bricks, you may damage the firebox and cause the paint to whiten.

In the case of the FX 3000, the exterior air intake and combustion supply control is located underneath the door. It uses a push\pull technique. The air intake is opened when the control knob is completely pulled toward the front and closed when it is pushed toward the back.

It is extremely important that you use your stove in such a way that you do not lower the temperature of the combustion gases inside the chimney too much. For this purpose, we strongly recommend that you install a Drolet chimney thermometer on your exhaust pipe, approximately 18" above the stove. Contact your Drolet dealer in order to buy one. This thermometer will indicate the temperature of your exhaust gases inside the exhaust system. The ideal temperature range is indicated on the thermometer. If temperature is too low, the build-up of creosote is promoted while if temperature is too high, heat is wasted since too large a quantity is emitted into the atmosphere.

In summary, it is very easy to operate your wood stove and you can prevent all potential problems by following these recommendations:

1)Select a stove of adequate size: selecting a stove that is too big for the area to be heated is a common mistake;

2)Follow the installation standards scrupulously and respect the clearances to combustible material;

3)Burn only dried wood, that is, with a maximum 20% humidity content;

4)Install a chimney thermometer on your stove pipe, 18" (457 mm) above the stove, and maintain the temperature of your exhaust gases between 250°F and 475°F.

Keep in mind that the most difficult months for wood heating are October and November. Indeed, during this period, the atmosphere is often very heavy and humid, and may hinder the chimney draft. Moreover, the wood is often too damp, since it has not had a sufficient drying period, or it has been stored outside in the rain. Combustion problems may then occur.

Important:

It is important to note that wood combustion consumes ambient oxygen in the room. In the case of negative pressure, it is a good idea to allow for a fresh air intake in the room, either by opening a window slightly or by installing a fresh air intake system on an outside wall.

21

Image 21
Contents WOOD STOVE MANUAL 1700, Léon-Harmel Québec Qc Canada G1N 4R9 Tel FaxSTOVE BUILDER INTERNATIONAL 29/08/2005INSTALLATION OF YOUR DROLET WOOD STOVE TABLE OF CONTENTSBAFFLE BRICK INSTALLATION SAWMAN STOVE ONLY THE DROLET WOOD STOVE MANUALWOOD HEATING INTRODUCTION THE DROLET WOOD STOVE MANUALTHE CONTROLLED COMBUSTION WOOD STOVE KEEP THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE1- Mount the 4 legs using 2 screws per leg ASSEMBLING THE STOVE2- Mount the ash lip with two screws 4- Bend the heat shield slightly to make it fit between the back legsINSTALLING THE FIREBRICKS POSITIONING THE STOVE INSTALLATION OF YOUR DROLET WOOD STOVEFLOOR PROTECTION ModelsCLEARANCES CLEARANCES TO COMBUSTIBLE MATERIALSModel Back WallFOR BARON 1880SP & 2000SP USING THE ENVELOPE INSTALLATION OF A HEAT RADIATION SHIELDTYPE OF PROTECTION SIDES ANDCHIMNEY STEP BY STEP INSTALLATION OF YOUR CHIMNEYWALL SUPPORT SYSTEM ChimneyStove pipe Page CEILING SUPPORT SYSTEM Suitable lengths of stove pipe Page COUPLINGS Page AIR CIRCULATION SYSTEM EXTERIOR AIR INTAKEA Rear Wall Connection B Floor ConnectionBAFFLE BRICK INSTALLATION SAWMAN STOVE ONLY FUEL OPERATING YOUR DROLET WOOD STOVEAVERAGE ENERGY YIELD OF ONE AIR DRIED CORD OF CUT WOOD High Energy YieldBefore your first fire IGNITIONHEATING MAINTENANCE OF THE STOVE MAINTENANCE OF THE HEATING SYSTEMMAINTENANCE OF THE CHIMNEY PROCEDURES IN CASE OF FIREIN CASE OF FIRE CALL IMMEDIATELY THE FIRE DEPARTMENTWHAT DO THE WORDS “DRAFT” AND “NEGATIVE PRESSURE” MEAN? FREQUENTLY ASKED QUESTIONSDRAWING #1 DRAWING #2 DRAWING #3 DRAWING #4 DRAWING #5 WHEN DO IN NEED TO REPLACE THE FIREBRICKS? CAN I MODIFY MY STOVE TO INSTALL A GLASS DOOR?WARRANTY APPLICATION LIMITED LIFETIME WARRANTYPARTS LABOUR