England's Stove Works 55-SHPEPI, 55-TRPEPI Approved Venting Method 3 Existing Chimney System

Page 13

FREESTANDING INSTALLATION

Approved Venting Method 3: Existing Chimney System

Using an existing masonry or factory built chimney for venting is the only other acceptable method for venting this pellet unit.

Use Type L or Type PL venting pipe until entering the existing chimney. Use the appropriately sized adapter when transitioning from the pellet vent pipe to the masonry or factory built thimble and be certain that the adapter is sealed tightly to both the pellet venting system and the existing chimney.

Before using an existing chimney, be certain it is in good condition (A chimney sweep inspection is highly recommended). Also, make sure the chimney meets the minimum standards listed in NFPA 211 (A chimney professional can confirm this upon inspection).

If connecting this stove to a factory built chimney, it may ONLY be a 6” flue, UL103 HT venting system.

Connection to any other factory built chimney may

result in a poorly operating or dangerous stove installation.

When connecting to an existing masonry chimney, the cross-sectional area of the flue must be considered. A chimney with a flue larger than 6” round (28.27 sq. in.) may require relining with an approved pellet stove chimney lining system.

Use an appliance collar where the pellet vent connects to the exhaust output of the pellet stove and attach the appliance collar to the exhaust blower output using three sheet metal screws.

Seal each pipe connection joint with high temperature RTV Silicone, to ensure the system is leak free (Check with the specific pipe manufacturer’s instructions before doing so).

If the pellet vent pipe being used is not a “Twist Lock” system, three (3) sheet metal screws are required at each pipe joint.

Connect the pellet stove to outside combustion air using the kit included with your stove or using an alternative method, as described in the “Outside Air” section, on page 15.

For high altitude installations (above 4,000 ft.), the vent pipe should be

increased from 3-inch (3”) to four-inch (4”).

Please Note:

Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local codes.

Page 13

Image 13 Contents
Evolution Pellet Stove Safety NoticeRetain for your files Table of Contents Introduction Heating Specifications SpecificationsEPA and Safety Compliance Specifications Fireplace Insert Dimensions Freestanding Installation Clearances to Combustibles Unit Clearances to Combustibles Freestanding Installation Freestanding Installation Please Note Approved Venting Method 1 Through the WallApproved Venting Method 2 Through the Ceiling Approved Venting Method 3 Existing Chimney System Freestanding Installation Outside AIR HOOK-UP Freestanding Floor Protection  Tools Required Fireplace Insert InstallationFireplace Insert Installation Clearance to Mantle a Fireplace Insert Installation Fireplace Insert Installation Please Note Outside AIR HOOK-UP Floor Protection Daily Operation Page Control Board Settings Error Codes OFF Power FailureThermostat Operation Thermostat Operation Details Daily Maintenance Daily Maintenance Daily Maintenance Biweekly Maintenance Biweekly Maintenance Monthly Maintenance Monthly Maintenance Monthly Maintenance Soot and Fly Ash Formation and Need for Removal Yearly Maintenance For the fireplace insert  For the freestanding unitFreestanding Unit Yearly Maintenance Yearly Maintenance Trouble‐Shooting Guide ‐1 Code On Control Board Replacing Components Replacing Components Replacing Components Replacing Components Recommended Heat Ranges Wiring Diagram Standard Accessories Optional AccessoriesIllustrated Parts Diagram Freestanding Illustrated Parts Diagram Insert Replacement Parts List Page Manufacturer extends the following warranties Limited Five 5 Year WarrantyWarranty is not transferable Page Warranty Registration for England’s Stove Works 434 929-4810 Twenty-four hours a day Visit our warranty registration website at