FLOOR PROTECTION

The 25-EPI requires a non-combustible hearth if the current hearth of the fireplace does not extend the required distance from the front of stove. Follow the diagram below to determine if the current fireplace hearth is sufficient.

If the current fireplace hearth is not large enough to accommodate this insert, a hearth extension pad (which is designed and sold specifically for this purpose) can be used. A hearth extension pad should be U.L. listed, or equivalent, and must only be noncombustible. Since the majority of the radiant heat from this unit is projected forward, the hearth extension pad only serves to keep ashes and sparks from landing on combustible flooring near the unit. A hearth rug is NOT an approved substitute for a proper hearth extension pad.

Page 24

Required Floor Protection Distance From

Unit

Front ( A )

Side ( B )

6 IN.

6 IN.

152.4 MM.

152.4 MM.

*THIS CONCLUDES THE FIREPLACE INSERT INSTALLATION SECTION

Image 24 Contents
Safety Notice Evolution Pellet StoveRetain for your files Table of Contents Introduction Specifications Heating SpecificationsEPA and Safety Compliance Specifications Fireplace Insert Dimensions Freestanding Installation Unit Clearances to Combustibles Clearances to CombustiblesFreestanding Installation Freestanding Installation Approved Venting Method 1 Through the Wall Please NoteApproved Venting Method 2 Through the Ceiling Approved Venting Method 3 Existing Chimney System Freestanding Installation Outside AIR HOOK-UP Freestanding Floor Protection Fireplace Insert Installation  Tools RequiredFireplace Insert Installation Clearance to Mantle a Fireplace Insert Installation Fireplace Insert Installation Please Note Outside AIR HOOK-UP Floor Protection Daily Operation Page Control Board Settings Error Codes Power Failure OFFThermostat Operation Thermostat Operation Details Daily Maintenance Daily Maintenance Daily Maintenance Biweekly Maintenance Biweekly Maintenance Monthly Maintenance Monthly Maintenance Monthly Maintenance Yearly Maintenance Soot and Fly Ash Formation and Need for Removal For the freestanding unit  For the fireplace insertFreestanding Unit Yearly Maintenance Yearly Maintenance Trouble‐Shooting Guide ‐1 Code On Control Board Replacing Components Replacing Components Replacing Components Replacing Components Recommended Heat Ranges Wiring Diagram Optional Accessories Standard AccessoriesIllustrated Parts Diagram Freestanding Illustrated Parts Diagram Insert Replacement Parts List Page Limited Five 5 Year Warranty Manufacturer extends the following warrantiesWarranty is not transferable Page Warranty Registration for England’s Stove Works Visit our warranty registration website at 434 929-4810 Twenty-four hours a day