England's Stove Works 55-TRPEPI, 55-SHPEPI operation manual Replacing Components

Page 48

REPLACING COMPONENTS

Convection Blower

1.Before beginning any component replacement, be certain the unit is unplugged and thoroughly cooled down.

2.Freestanding: Remove the right side panel as previously detailed in this manual on Page 41 in the “Exhaust Blower Cleaning” section. Fireplace Insert: The unit will need to be at least partially removed from the fireplace opening (or alternatively, the surround kit and side panels can be removed to access the blower).

3.Detach the convection blower from the wiring harness before loosening the four screws which secure it to the convection shroud of the stove.

4.After loosening and removing the four screws which hold the blower to the stove, remove the blower from the stove.

5.Installation of the new blower is performed in reverse of removal; remember to reconnect the new blower to the wiring harness before reinstalling the side panel.

Combustion Blower

1.Before beginning any component replacement, be certain the unit is unplugged and thoroughly cooled down.

2.Freestanding: Remove the left side panel as previously detailed on pg. 41. Fireplace Insert: Remove the unit from the fireplace.

3.Disconnect the venting system from the exhaust blower, and disconnect the exhaust blower from the stove wiring harness. Loosen and remove the thermal sensor screw on the top of the exhaust blower outlet using a 5/16” wrench.

4.Loosen and remove all five screws which hold the exhaust blower to the exhaust blower tube. Once the screws have been removed, the blower can be lifted up and out of the stove.

5.Reinstallation is the exact opposite of the steps above; however be certain to check the condition of the exhaust blower gasket and replace if necessary.

Page 48

Image 48 Contents
Safety Notice Evolution Pellet StoveRetain for your files Table of Contents Introduction Specifications Heating SpecificationsEPA and Safety Compliance Specifications Fireplace Insert Dimensions Freestanding Installation Unit Clearances to Combustibles Clearances to CombustiblesFreestanding Installation Freestanding Installation Approved Venting Method 1 Through the Wall Please NoteApproved Venting Method 2 Through the Ceiling Approved Venting Method 3 Existing Chimney System Freestanding Installation Outside AIR HOOK-UP Freestanding Floor Protection Fireplace Insert Installation  Tools RequiredFireplace Insert Installation Clearance to Mantle a Fireplace Insert Installation Fireplace Insert Installation Please Note Outside AIR HOOK-UP Floor Protection Daily Operation Page Control Board Settings Error Codes Power Failure OFFThermostat Operation Thermostat Operation Details Daily Maintenance Daily Maintenance Daily Maintenance Biweekly Maintenance Biweekly Maintenance Monthly Maintenance Monthly Maintenance Monthly Maintenance Yearly Maintenance Soot and Fly Ash Formation and Need for Removal For the freestanding unit  For the fireplace insertFreestanding Unit Yearly Maintenance Yearly Maintenance Trouble‐Shooting Guide ‐1 Code On Control Board Replacing Components Replacing Components Replacing Components Replacing Components Recommended Heat Ranges Wiring Diagram Optional Accessories Standard AccessoriesIllustrated Parts Diagram Freestanding Illustrated Parts Diagram Insert Replacement Parts List Page Limited Five 5 Year Warranty Manufacturer extends the following warrantiesWarranty is not transferable Page Warranty Registration for England’s Stove Works Visit our warranty registration website at 434 929-4810 Twenty-four hours a day