England's Stove Works 55-TRPEPI, 55-SHPEPI operation manual Thermostat Operation

Page 30

THERMOSTAT OPERATION

Thermostat Installation

1.Unplug the unit and remove the back panel of the stove.

2.Locate the thermostat connect block, labeled J18, on the rear of the control board, near the bottom (See image below and pg. 52 of this manual for a control board diagram). It will have a small wire “jumper” installed in it from the factory. This jumper bypasses the thermostat and should be saved.

3.Loosen the two screws using a small slotted “jewelers” screwdriver and remove the “jumper.”

4.Insert the two thermostat wires in place of the “jumper” and retighten the screws.

5.Reinstall the back panel and mount the thermostat; the control board automatically reads the thermostat and your stove is now ready for thermostat operation.

Connect

thermostat wires here (J18)

Page 30

Image 30 Contents
Safety Notice Evolution Pellet StoveRetain for your files Table of Contents Introduction Specifications Heating SpecificationsEPA and Safety Compliance Specifications Fireplace Insert Dimensions Freestanding Installation Unit Clearances to Combustibles Clearances to CombustiblesFreestanding Installation Freestanding Installation Approved Venting Method 1 Through the Wall Please NoteApproved Venting Method 2 Through the Ceiling Approved Venting Method 3 Existing Chimney System Freestanding Installation Outside AIR HOOK-UP Freestanding Floor Protection Fireplace Insert Installation  Tools RequiredFireplace Insert Installation Clearance to Mantle a Fireplace Insert Installation Fireplace Insert Installation Please Note Outside AIR HOOK-UP Floor Protection Daily Operation Page Control Board Settings Error Codes Power Failure OFFThermostat Operation Thermostat Operation Details Daily Maintenance Daily Maintenance Daily Maintenance Biweekly Maintenance Biweekly Maintenance Monthly Maintenance Monthly Maintenance Monthly Maintenance Yearly Maintenance Soot and Fly Ash Formation and Need for Removal For the freestanding unit  For the fireplace insertFreestanding Unit Yearly Maintenance Yearly Maintenance Trouble‐Shooting Guide ‐1 Code On Control Board Replacing Components Replacing Components Replacing Components Replacing Components Recommended Heat Ranges Wiring Diagram Optional Accessories Standard AccessoriesIllustrated Parts Diagram Freestanding Illustrated Parts Diagram Insert Replacement Parts List Page Limited Five 5 Year Warranty Manufacturer extends the following warrantiesWarranty is not transferable Page Warranty Registration for England’s Stove Works Visit our warranty registration website at 434 929-4810 Twenty-four hours a day