England's Stove Works 55-SHP22, 55-TRP22E Accessory Items, Thermostats, AC-103, AC-103BN Lip Trim

Page 17

ACCESSORY ITEMS

The following accessories can be added to your unit at anytime after purchase; however, let

the unit cool down before adding any accessories.

Thermostats

WALL: An external wall thermostat (such as our Part # GU-1E30-914) can be used on our pellet units as long as it is a low-voltage that works with millivolt systems. After unplugging the unit, locate the jumper wire (J-3) on the bottom of the control panel. The two screws should then be loosened and the jumper wire removed from the board. Next, the two thermostat lead wires should be slipped into these openings and the screws tightened; the jumper wire should be saved for future operation without a thermostat.

The unit will operate differently once the wall thermostat is connected – we recommend the Control Board be set at “9” on Heat Range and Blower Speed while using the thermostat. Refer to the section on “Start-up Procedure” for information on cold starts.

AC-103, AC-103BN Lip Trim

There is one piece of J-Channel trim in this kit that snaps onto the ash apron lip of the

stove. Match the channel with the correct edge of the ash apron, then remove the protective covering from the trim and force the piece onto the edge. Although it should stay in place, stove cement can be used to secure it if necessary.

NOTE: For stoves manufactured prior to 2001, the part number for this kit is AC-101-PU.

AC-106-P (SH-106-P), AC-106-PBN Window Trim

This trim can be attached by using the provided spring clip and some high temperature silicone. Insert the tee end of the spring clip into the opening on the edge of the trim – this will allow the clip to fall into the groove. The spring clip will hold well if it is placed on the bottom edge of the trim. We also suggest that high temperature silicone be used on the corners, to ensure the trim will stay in place.

Accessories can be ordered from the factory at:

(Parts orders ONLY) -- (800) 516-3636, or on our web site: www.englandsstoveworks.com .

Questions/Problems: Please call Customer Service at (800) 245-6489.

Image 17
Contents Be maintained PDVE, 55-SHP22E, and 55-TRP22ELetter from our Technical Support department Important Information Unit Preparation Page Through the Wall Flue SystemPellet Vent Pipe Through the Ceiling Mobile Home InstallationExisting Flue System Outside Air Outside Combustion Air IntakeWall Protection Floor and Wall ProtectionFloor Protection Operating Instructions START- UP ProcedureHorizontal Feed System Manually Starting Your UnitCodes SHUT-DOWN ProcedureDaily Operation Page Annual Cleaning MaintenanceAuger Motors Auger Bearings and Auger Shafts Convection Blower Vacuum Switch Combustion Blower GasketsRecommended Heat Ranges Control BoardIllustration 2b Control Board Diagram Wiring Thermostats Accessory ItemsAC-103, AC-103BN Lip Trim AC-106-P SH-106-P, AC-106-PBN Window TrimCustomer Service Department Replacement PARTS, Accessories and OptionsOptions Box Parts Orders only Monroe, VA Questions 800-245-6489 FaxPellet Stove Exploded View Diagram Hopper LID Latches Problem Cause Solution TROUBLE-SHOOTING GuideFive Year Period ProcedureThree Year Period One Year PeriodUnit Information Dealer Information