Enviro C-10914 owner manual Once, Wall Framing for Hole for Vertical

Page 20

Initial Installation

QUALIFIED INSTALLERS ONLY

VERTICAL INSTALLATION:

STEP 1. Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. Do not pack air spaces with insulation.

STEP 2. Set the gas appliance in the desired location. Drop a plumb bob down from the ceiling to the position of the appliance flue exit, and mark the location where the vent will penetrate the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole previously drilled in the ceiling, mark the spot where the vent will penetrate the roof. Determine if ceiling joists, roof rafters, or other framing will obstruct the venting system. You may wish to relocate the appliance, or to offset, to avoid cutting load bearing members.

STEP 3. To install the Round Support Box/Wall Thimble in a flat ceiling, cut a 10” square hole in the ceiling, centered in the hole drilled in Step 2. Frame the hole as shown in Figure 23.

STEP 4. Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up through the Round Support Box. Insure that all pipe and elbow connections are in their fully twist- locked position.

STEP 5. Cut hole in the roof centered on the small

 

hole placed in the roof from Step 2. The

 

hole should be of sufficient size to meet

 

minimum

requirements

for

Clearance

 

to Combustibles,

as

specified. Continue

Figure 23: Wall Framing for Hole for Vertical

to assemble lengths of pipe and elbows

Installation.

necessary to

reach

from

 

 

Vertical

the ceiling

support

box

 

 

 

 

Termination

up through the roof line.

 

 

 

 

 

Galvanized

 

pipe

and

 

Elbow Strap

Storm Collar

elbows may

be

utilized

 

 

 

in the attic, as well as

 

 

Flashing

above

the

roof

line.

 

 

 

The galvanized

finish is

 

 

Roofing nails

desirable above

the

roof

 

 

 

 

 

line, due to the higher

 

 

 

corrosion resistance.

 

 

 

 

STEP 6. Once

the

pipe

sections

 

 

 

have

been

 

joined,

and

 

 

 

run up through the hole

 

 

 

in the roof, slip an elbow

 

 

 

strap

over

the

exposed

 

 

 

sections,

 

bend

the

 

 

 

support straps outwards,

 

Figure 24: Vertical Vent Termination Installation.

and push the elbow strap

 

20

Image 20
Contents For Your Safety WestportSafety Precautions GeneralTable of Contents Rear Vent DV Codes And ApprovalsTOP Vent DV Specifications DimensionsFor Your Safetyread Before Operating Operating InstructionsGas valve Maintenance And Service Electronic Ignition Module LocationTo Replace Handles for Removing DoorTo be Installed by a Qualified Service Agency only StepConversion instructions Natural Gas Initial Installation Qualified Installers onlyManufacturer Trade Name Nominal Sizes Are Permitted to Reach the Outside Vent Termination Run Common Horizontal Installation Pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand Off Do not interfere with the structural integrity of the walls Once Wall Framing for Hole for VerticalRoof Pitch Minimum Height Feet Meters Multi-Story Vent Pipe Installation Installation Instructions KIT ComponentsCut away of spacers on Flex Pipe Fire stop Assembly of Venting into a Class ‘A’ Chimney Turn the elbow to the rear vent position and re-fasten with Screws removed in see FigureCorner Installation Installation for Top Vented Horizontal TerminationInstallation Wiring DiagramCanadian Installations A. InstallationsGeneral Venting Information Venting of a Fireplace Fitted with the Drafthood AdaptorOptional Finishing Automatic Safety Shut DownSpill Switch Replacement GAS Line Connection To Test Valve PressuresWire Size Max. Length Wiring Diagram For Fan ControlSecondary Installation Optional Blower Fan InstallationComplete Log Placement Log Placement with Rock Wool Brick panel bracket, slots shown Trouble Shooting Problem Possible Cause SolutionParts List Cast Reference Number Part Description Part NumberCast Leg Each Painted Parts Diagram Cast Parts List Components Reference Part Description Part NumberParts List Components Parts Diagram Components Warranty To the DealerInstallation Data Sheet

C-10914 specifications

Enviro C-10914 is a cutting-edge eco-friendly product designed to meet the demands of modern environmental sustainability. With a mission to combat pollution and reduce waste, Enviro C-10914 combines advanced technologies and innovative features to create a robust solution for various applications ranging from industrial processes to home usage.

One of the standout features of Enviro C-10914 is its bio-based composition. Made primarily from renewable resources, this product significantly lowers the carbon footprint compared to traditional counterparts. By utilizing biodegradable materials, it ensures that its lifecycle is more sustainable, addressing the pressing issue of plastic waste in the environment.

Incorporating nanotechnology, Enviro C-10914 enhances its performance through improved durability and resilience. This technology not only increases the longevity of the product but also reduces the need for frequent replacements, promoting a more sustainable consumption model. The nanoscale modifications result in superior resistance to chemicals, UV light, and extreme weather conditions, making it suitable for a variety of applications.

Another key characteristic of Enviro C-10914 is its versatility. It is designed for use in diverse sectors, including agriculture, construction, and consumer goods. In the agricultural sector, for instance, it can be utilized in soil amendments, promoting better crop yield while being safe for both plants and animals. In construction, it serves as an eco-friendly alternative for insulation and waterproofing materials.

The product also features an innovative packaging solution that is user-friendly and minimizes material waste. The design allows for easy handling and application, ensuring that users can maximize its benefits without unnecessary burden.

Additionally, Enviro C-10914 is backed by rigorous testing and certifications that validate its environmental claims. Third-party evaluations confirm its biodegradability and overall effectiveness, providing consumers with confidence in their choices.

In summary, Enviro C-10914 exemplifies the future of sustainable products. With its bio-based materials, nanotechnology enhancements, and versatile applications, it stands at the forefront of eco-innovation, addressing the challenges of pollution and resource depletion in an effective, user-friendly manner. This makes it an essential choice for individuals and businesses alike who are committed to making environmentally responsible decisions.