Enviro C-10914 owner manual Trouble Shooting, Problem Possible Cause Solution

Page 38

Trouble Shooting

Problem

Possible Cause

Solution

Spark will not light

Defective piezo ignitor.

• Check connections to ignitor.

the pilot after

 

• If ignitor connections are good but no spark,

repeatedly pressing

 

replace ignitor.

the spark ignitor

 

 

Broken spark electrode.

• Check for broken ceramic insulation.

 

 

• Replace electrode if broken.

 

Low battery or bad

• Replace the electronic module.

 

electronic module.

• Replace the battery in module.

 

Misaligned spark

• If spark is not arcing from electrode to pilot - adjust

 

electrode.

by loosening the screws on the pilot base. Adjust

 

 

away from burner and retighten.

 

 

 

Pilot will not remain

Problem with

• Check for proper connection of the thermocouple to

lit

thermocouple circuit.

the rear of the valve. If loose, fully tighten lightly.

 

 

• Check pilot for full flame impingement around

 

 

thermocouple. If flame is too small, check gas

 

 

pressure, adjust pilot rate screw, check pilot head for

 

 

damage or blockage.

 

 

• Check thermocouple voltage at rear of valve.

 

 

It must be greater than 7 mV. If low, replace

 

 

thermocouple.

 

Air in gas line (pilot

• Bleed line.

 

dies while knob is

• Check gas line pressure.

 

depressed).

• Contact dealer.

Burners will not

Problem with

• Check gas line pressure .

remain lit

thermopile circuit.

• Check for flame impingement on thermopile. If low,

 

 

see “Pilot will not remain lit”.

 

 

• Check thermopile for minimum of 200 mV when

 

 

burner is switched on.

 

 

• Check wiring to thermostat for breaks.

Flame lifting

Leak in vent pipe.

• Check for leaks in vent connections.

 

 

 

 

Improper vent

• Check vent configuration with manual.

 

configuration.

 

 

 

 

 

Terminal may be

• Check to see if terminal is on correctly.

 

recirculating flue gases.

• May need to install high wind termination cap.

 

 

• Contact dealer.

 

 

 

 

Improperly set vent

• See venting section for proper restrictor setting.

 

restrictor plate.

 

Glass fogs up

Normal Condition: after the appliance warms up the glass will clear.

 

**Due to additives in gas, glass may get hazy during operation** Clean as

 

needed.

 

Blue Flames

Normal during start up: flames will yellow as the fireplace heats up.

 

 

 

Flames are burning

Flame impingement

• Check log positioning.

“dirty” or sooting

 

• Check vent restrictor for proper setting.

 

 

• Increase primary air by opening venturi shutter.

 

 

• See also “Burners will not remain lit.”

 

 

 

38

Image 38
Contents For Your Safety WestportSafety Precautions GeneralTable of Contents Rear Vent DV Codes And ApprovalsTOP Vent DV Specifications DimensionsFor Your Safetyread Before Operating Operating InstructionsGas valve Maintenance And Service Electronic Ignition Module LocationTo Replace Handles for Removing DoorTo be Installed by a Qualified Service Agency only StepConversion instructions Natural Gas Initial Installation Qualified Installers onlyManufacturer Trade Name Nominal Sizes Are Permitted to Reach the Outside Vent Termination Run Common Horizontal Installation Pipes and fittings, are Installing Vent Cap with Vinyl Siding Stand Off Do not interfere with the structural integrity of the walls Once Wall Framing for Hole for VerticalRoof Pitch Minimum Height Feet Meters Multi-Story Vent Pipe Installation Installation Instructions KIT ComponentsCut away of spacers on Flex Pipe Fire stop Assembly of Venting into a Class ‘A’ Chimney Turn the elbow to the rear vent position and re-fasten with Screws removed in see FigureCorner Installation Installation for Top Vented Horizontal TerminationInstallation Wiring DiagramGeneral Venting Information Canadian InstallationsA. Installations Venting of a Fireplace Fitted with the Drafthood AdaptorOptional Finishing Automatic Safety Shut DownSpill Switch Replacement GAS Line Connection To Test Valve PressuresWire Size Max. Length Wiring Diagram For Fan ControlSecondary Installation Optional Blower Fan InstallationComplete Log Placement Log Placement with Rock Wool Brick panel bracket, slots shown Trouble Shooting Problem Possible Cause SolutionParts List Cast Reference Number Part Description Part NumberCast Leg Each Painted Parts Diagram Cast Parts List Components Reference Part Description Part NumberParts List Components Parts Diagram Components Warranty To the DealerInstallation Data Sheet

C-10914 specifications

Enviro C-10914 is a cutting-edge eco-friendly product designed to meet the demands of modern environmental sustainability. With a mission to combat pollution and reduce waste, Enviro C-10914 combines advanced technologies and innovative features to create a robust solution for various applications ranging from industrial processes to home usage.

One of the standout features of Enviro C-10914 is its bio-based composition. Made primarily from renewable resources, this product significantly lowers the carbon footprint compared to traditional counterparts. By utilizing biodegradable materials, it ensures that its lifecycle is more sustainable, addressing the pressing issue of plastic waste in the environment.

Incorporating nanotechnology, Enviro C-10914 enhances its performance through improved durability and resilience. This technology not only increases the longevity of the product but also reduces the need for frequent replacements, promoting a more sustainable consumption model. The nanoscale modifications result in superior resistance to chemicals, UV light, and extreme weather conditions, making it suitable for a variety of applications.

Another key characteristic of Enviro C-10914 is its versatility. It is designed for use in diverse sectors, including agriculture, construction, and consumer goods. In the agricultural sector, for instance, it can be utilized in soil amendments, promoting better crop yield while being safe for both plants and animals. In construction, it serves as an eco-friendly alternative for insulation and waterproofing materials.

The product also features an innovative packaging solution that is user-friendly and minimizes material waste. The design allows for easy handling and application, ensuring that users can maximize its benefits without unnecessary burden.

Additionally, Enviro C-10914 is backed by rigorous testing and certifications that validate its environmental claims. Third-party evaluations confirm its biodegradability and overall effectiveness, providing consumers with confidence in their choices.

In summary, Enviro C-10914 exemplifies the future of sustainable products. With its bio-based materials, nanotechnology enhancements, and versatile applications, it stands at the forefront of eco-innovation, addressing the challenges of pollution and resource depletion in an effective, user-friendly manner. This makes it an essential choice for individuals and businesses alike who are committed to making environmentally responsible decisions.