Initial Installation

 

 

 

 

 

 

 

QUALIFIED INSTALLERS ONLY

the termination and the wall. The arrow on the vent termination

 

should

 

be

pointing up, insure that the proper clearances to

10"

combustible materials are maintained.

(254mm)

 

5. Before connecting the horizontal run of the vent pipe to the vent

 

termination, slide the black decorative wall thimble cover over the

10"

vent pipe.

 

 

 

 

 

 

(254mm)

 

 

 

 

 

 

 

6. Slide the appliance and vent assembly towards the wall, carefully

 

inserting the vent pipe into the cap assembly. It is important that

 

the vent pipe extend into the vent cap a sufficient distance with a

 

minimum of 11⁄4” (3.2cm) overlap. Secure the connection between

 

the vent cap pipe and the vent cap by attaching the two sheet

 

metal straps extending from the vent cap assembly into the outer

 

wall of the vent pipe. Use the two sheet metal screws provided to

 

connect the straps to the vent pipe. Bend any remaining portion of

Figure 27: Wall Framing Hole for

the sheet metal straps back towards the vent cap, so the decorative

Horizontal Installation.

wall thimble will conceal it (see left image in Figure 28).

 

7. Slide

the

decorative

wall

11/4"

 

thimble

up

to

the

wall

 

surface

and

attach

with

(3.2cm)

 

 

 

the screws

provided. Apply

Fold strap

Woodscrews

decorative

brass

or

chrome

here

 

trim if desired (see right

 

 

image in Figure 28).

 

 

Sheet metal

 

 

 

 

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

screws

 

(a) The four (4) wood screws

 

 

provided

 

should

be

replaced

 

 

with the appropriate fasteners

Wall Thimble

 

for stucco, brick, concrete, or

Strap

 

other types of siding.

 

 

Figure 28: Installing Decorative Wall Thimble.

 

 

 

 

 

 

 

 

Figure 29: Installing Vent Cap with Vinyl Siding

Figure 30: Installing Horizontal Vent

Stand-Off.

Termination.

18

Image 18
Contents Cara DR Safety Precautions GeneralTable of Contents Codes And Approvals Vented GAS Fireplace Heater Cara DR DV NG/LPGThis Enviro Cara DR Fireplace Specifications Cara DR Exterior DimensionsFor Your Safety Read Before Operating Operating InstructionsCara Component Sound & Reason Maintenance And Service Pilot FlameNo substitute materials are allowed Check burner for proper operation Kit Parts List Conversion Kit InstallationOpen Flame When Testing for Leaks Initial Installation Qualified Installers only Manufacturer Trade Name Nominal Sizes Vent Termination Restrictions 51mm at top, 11⁄2 38mm at sides, 11⁄2 38mm at bottom Twist-LockThimble Wall Surface Attach With Installation for Cara DR Manifold Pressure Venturi SettingNatural Gas Propane Main Burner Min. Manifold PressureWire Size Max. Length Canadian InstallationsA. Installations Optional Blower Fan Installation Secondary Installation Log Placement of Rear Log ChunksLog Placement of Left Log Remove door to clean glass Addition the seven 7 small rocks. These can be To clean glass Trouble Shooting Problem Possible Cause SolutionParts List Reference Part Description Part NumberParts List Parts Diagram Warranty To the DealerWarranty Warranty Installation Data Sheet