Enviro 50-1628, Cara DR, C-11366 Secondary Installation, Log Placement of Rear Log Chunks

Page 23

Secondary Installation

INSTALLATION OF LOG SET:

The placement of the logs is not arbitrary. If they are positioned incorrectly, the flames can be “pinched” and will not burn correctly. The burner has four (4) pins and four (4) ledges which make alignment easier. Using the pictures provided, carefully set the logs in place.

NOTE: The logs are fragile and should be handled gently.

1.Carefully remove logs from box and check there is no damage. It is very important to install all logs in their proper position to ensure safe, optimum operating conditions.

2.Place the Left Rear Log Chunk on the two (2) left rear pins and the Right Rear Log Chunk on the two (2) right rear pins (refer to Figures 37 and 38).

3.Place the bottom of the “Y” Log in the ledge at the front left of the burner and the top of the log rests on the Right Rear Log Chunk as shown in Figure 38 and 39.

4.Place the bottom of the Right Log in the ledge at the front right of the burner and rest the top of the log against the rear panel as shown in Figure 39 and 40.

Figure 37: Log Placement of Rear Log Chunks.

Figure 38: Log Placement of “Y” Log.

Figure 39: Log Placement of Right Log.

23

Image 23
Contents Cara DR General Safety PrecautionsTable of Contents This Enviro Cara DR Fireplace Codes And ApprovalsVented GAS Fireplace Heater Cara DR DV NG/LPG Cara DR Exterior Dimensions SpecificationsOperating Instructions For Your Safety Read Before OperatingCara Component Sound & Reason Pilot Flame Maintenance And ServiceNo substitute materials are allowed Check burner for proper operation Conversion Kit Installation Kit Parts ListOpen Flame When Testing for Leaks Qualified Installers only Initial InstallationManufacturer Trade Name Nominal Sizes Vent Termination Restrictions Twist-Lock 51mm at top, 11⁄2 38mm at sides, 11⁄2 38mm at bottomThimble Wall Surface Attach With Installation for Cara DR Min. Manifold Pressure Venturi Setting Natural Gas Propane Main Burner Manifold PressureA. Installations Wire Size Max. LengthCanadian Installations Optional Blower Fan Installation Log Placement of Rear Log Chunks Secondary InstallationLog Placement of Left Log Remove door to clean glass Addition the seven 7 small rocks. These can be To clean glass Problem Possible Cause Solution Trouble ShootingReference Part Description Part Number Parts ListParts List Parts Diagram To the Dealer WarrantyWarranty Warranty Installation Data Sheet
Related manuals
Manual 37 pages 22.56 Kb