Enviro Cara DR, C-11366, 50-1628 owner manual Maintenance And Service, Pilot Flame

Page 9

Maintenance And Service

ROUTINE MAINTENANCE:

At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips.

Warning: Clearances must be sufficient to allow access for maintenance and service

Warning: Failure to position the parts in accordance with this manual, or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

The venting system must be periodically examined; it is recommended the examination is done by a qualified agency.

CLEANING THE PAINTED SURFACES:

Painted faces should be wiped with a damp cloth periodically.

CHECK PILOT AND BURNER FLAMES:

Periodically do a visual check of the pilot flames. One flame should encompass the ignitor and thermocouple and the other should burn over the burner ports (see Figure 6). Also check that the burner is operating correctly, refer to Figure Figure 43 or Front Cover.

Figure 6: Pilot Flame.

GLASS DOOR REMOVAL:

IMPORTANT: If the door is not engaged properly on the hooks, damage to the fireplace and/or floor, personal injury, or even death may occur.

1.Turn the unit off and wait until it has cooled down.

2.Remove the cast iron louvers from above the door by lifting the louvers up and out.

3.Pull the two (2) door hooks, on top of the door, forward and up (see Figure 7).

4.Lift the glass door assembly straight up and out.

Ensure the door is properly fastened before attempting to light the appliance. To re- installing the glass door, slide the three (3) door hook slots, on the bottom of the door, over the three (3) door hooks on the unit. Pull the two (2) door hooks, on top of the door, forward and slide them into the two

(2) door hook slots.

Figure 7: Door Removal / Installation.

9

Image 9
Contents Cara DR General Safety PrecautionsTable of Contents Codes And Approvals Vented GAS Fireplace Heater Cara DR DV NG/LPGThis Enviro Cara DR Fireplace Cara DR Exterior Dimensions Specifications Operating Instructions For Your Safety Read Before OperatingCara Component Sound & Reason Pilot Flame Maintenance And ServiceNo substitute materials are allowed Check burner for proper operation Conversion Kit Installation Kit Parts ListOpen Flame When Testing for Leaks Qualified Installers only Initial InstallationManufacturer Trade Name Nominal Sizes Vent Termination Restrictions Twist-Lock 51mm at top, 11⁄2 38mm at sides, 11⁄2 38mm at bottomThimble Wall Surface Attach With Installation for Cara DR Natural Gas Propane Main Burner Venturi SettingManifold Pressure Min. Manifold PressureWire Size Max. Length Canadian InstallationsA. Installations Optional Blower Fan Installation Log Placement of Rear Log Chunks Secondary InstallationLog Placement of Left Log Remove door to clean glass Addition the seven 7 small rocks. These can be To clean glass Problem Possible Cause Solution Trouble ShootingReference Part Description Part Number Parts ListParts List Parts Diagram To the Dealer WarrantyWarranty Warranty Installation Data Sheet
Related manuals
Manual 37 pages 22.56 Kb