Enviro C-11366, Cara DR, 50-1628 owner manual Optional Blower Fan Installation

Page 22

Initial Installation

INSTALLATION OF OPTIONAL BLOWER:

Figure 36: Optional Blower (Fan) Installation.

1.Remove the pre-assembled blower from the packaging. Inspect the blower for damage. If damage is noticed call your dealer, distributor or courier company and have components replaced.

2.Remove the side panel by pulling the panel up, slide the panel out of the bottom slots, and set aside.

3.Install the temperature sensor into the holder.

IMPORTANT: The temperature sensor must be in contact with the firebox.

4.Open the pedestal door and remove the four (4) T-20 screws holding the Control Panel in place.

5.Fit the Fan Unit into the cabinet being careful to work around the gas and pilot lines. The fan will fit up behind the gas valve. With an extension driver, fasten the Fan Unit in place with four (4) T-20 screws provided.

6.Install the Fan Controller into the provision in the Control Panel.

7.Install the Strain Relief plate into the stove back by fitting the tab on the plate into the stove back and secure the plate with a T-20 screw provided.

8.Plug in all the electrical connections as indicated in Figure 35. This includes the Fan Controller, Temperature sensor and Fan Unit.

9.Using the provided T-20 screw, located on the right mount below and behind the Temperature Sensor, fasten the wire tie supplied. With the wire tie capture the fan wires including the temperature switch wires, this will secure the wires and route them away from hot surfaces and out of the way of the fan blades

10.Re-install the Control Panel and Side Panel.

11.Plug the fan assembly into the wall outlet and turn the unit on to ensure fan operation.

22

Image 22
Contents Cara DR Safety Precautions GeneralTable of Contents Vented GAS Fireplace Heater Cara DR DV NG/LPG Codes And ApprovalsThis Enviro Cara DR Fireplace Specifications Cara DR Exterior DimensionsFor Your Safety Read Before Operating Operating InstructionsCara Component Sound & Reason Maintenance And Service Pilot FlameNo substitute materials are allowed Check burner for proper operation Kit Parts List Conversion Kit InstallationOpen Flame When Testing for Leaks Initial Installation Qualified Installers onlyManufacturer Trade Name Nominal Sizes Vent Termination Restrictions 51mm at top, 11⁄2 38mm at sides, 11⁄2 38mm at bottom Twist-LockThimble Wall Surface Attach With Installation for Cara DR Manifold Pressure Venturi SettingNatural Gas Propane Main Burner Min. Manifold PressureCanadian Installations Wire Size Max. LengthA. Installations Optional Blower Fan Installation Secondary Installation Log Placement of Rear Log ChunksLog Placement of Left Log Remove door to clean glass Addition the seven 7 small rocks. These can be To clean glass Trouble Shooting Problem Possible Cause SolutionParts List Reference Part Description Part NumberParts List Parts Diagram Warranty To the DealerWarranty Warranty Installation Data Sheet
Related manuals
Manual 37 pages 22.56 Kb