Enviro 1700, 1200 owner manual Installing Heat Shield

Page 20

Installation

LEGS AND ASH PAN INSTALLATION - FREESTANDING:

Place the unit on the pallet on its back.

Attach pedestal spacer to bottom of the unit, using the supplied screws.

Attach the air channel box to the front of the pedestal spacer using two (2) T-20 screws.

Slide the ash pan assembly over the bolts, using the key-holed slots provided, and tighten all four

(4)bolts.

Carefully remove the cast iron legs from the packaging and secure each leg with two (2) bolts provided.

Secure all four (4) legs, push the

Figure 15: Installing Legs and Ash Pan Assembly.

leg towards the center of the stove and align the legs with the outer edges of the firebox.

Stand the unit on the legs and set the unit in the location ready for installation.

INSTALLATION OF HEAT-EFFICIENCY SHIELD - FREESTANDING FLAT TOP:

The heat-efficiency shield is installed to lower the clearances to combustibles on the flat top freestanding model.

1.The unit must be in position for the installation and with the venting ready to be assembled.

2.Loosen the two (2) top screws on the back of the unit using a 5/16” socket.

3.Place the heat-efficiency shield on top of unit.

4.Slide chimney connector through the heat-efficiency shield and over the flue.

5.Lift the heat-efficiency shield and screw the chimney connector to the flue.

6.Slide the heat-efficiency shield down and hook the slot at the back of the shield, around the loosened screws at the back of the unit.

7.Tighten the two (2) screws at the back.

������� ���������

���� ������

����

������ ������

Figure 16: Installing Heat Shield.

20

Image 20
Contents Wood Stove Table of Contents Safety Precautions Operating Instructions First StartCreosote ITS Formation and Removal Helpful Hints Worth Repeating What type of wood is best to use as firewood? What can cause a poor draft? 1200 Air Flow Path Specifications Capacity Feet3 0.0708 meter3 Approximate heating area † From front of unit to edge of floor protection Maintain These Minimum Clearances to Unshielded Combustibles 1700 Freestanding Clearance to Combustibles 1200 Insert Dimensions 1200 Freestanding Flat Top Dimensions 1700 Freestanding Flat Top Dimensions 1200 Freestanding with Fan Kit Dimensions Installation Bolts to removeInstalling Heat Shield Recommended Height for Flue Pipe Chimney Through Wall Method a Roof Clearances Shield if required Installation into a masonry chimney Venting Outside AIR Insert Installation into existing fireplace with Hearth Metal TAG this Fireplace has Been Before starting this type of installation 3D of Dimensions needed from Fireplace Insert Install into a Zero-Clearance Fireplace Total Bricks Model 1700 Brick Placement Do not USE Door if Glass is Broken Installation of Ceramic Baffle Back View of Freestanding Unit with Fan Kit Removal of right pod This will keep the trim tight Parts List Parts List Parts Diagram Parts Diagram Pedestals & Legs Parts Diagram Fireplace Insert Warranty Limited Five 5 Year Warranty Limited One 1 Year WarrantyExclusions and Limitations Warranty Installation Data Sheet