Enviro 1700, 1200 owner manual Operating Instructions, First Start

Page 4

Operating Instructions

FIRST START

When first installed, the chimney, firebricks and steel are cold and it usually takes several hours on a fairly high burn for them to become hot and dry enough for the stove to function well. We recommend during the unit’s first burn that a door and window are opened to vent the smoke and fumes created from the unit’s paint curing. The paint will smell a little for the first burn or two as it cures.

FANS:

All models have been approved for operation with or without the optional fans supplied by the manufacturer. On medium or high burns, using a fan will increase the heat transfer slightly. Route the power supply cord along the floor behind the stove where it will remain cool.

DISPOSAL OF ASHES:

If you let the ashes accumulate two or three inches on the floor they tend to burn themselves up. Open the small trap door located on the floor of the unit. Push the ashes that have accumulated into the hole were the ashes would drop into the ash pan. Ensure that the trap door is closed properly before relighting the unit. When necessary, put the ashes in a metal container with a tightly fitting lid. Place the closed container on a non-combustible floor, well away from combustible materials. If the ashes are to be buried in soil or otherwise locally dispersed, keep them in a closed container until all cinders have cooled. If your model has an ash pan, be sure to latch the ash pan tightly when finished. Small amounts of cold wood ash can be used in the garden or compost.

REPLACING THE GLASS:

Never strike or slam the door, hit the glass or let burning wood rest against it. If the glass cracks when the fire is burning, do not open the door until the fire is out and do not operate the stove again until the glass has been replaced. If the glass is damaged in any way, a factory replacement is required (see “PARTS LIST”). To remove the door, open and lift. To replace the glass, remove the steel retaining clips and all loose glass. Replace only with Neoceram 5 mm glass 16.61” (422 mm) x 10.63” (270 mm) and wrap the edges with 0.125” (3.2 mm) x 0.5” (13 mm) self-adhesive fiberglass gasket.

Wear gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag.

The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed.

CLEANING THE PLATED SURFACES:

Painted faces should be wiped with a damp cloth periodically. If a plated door has been purchased, it should be unpacked carefully to avoid getting anything on the surface of the finish, including cleaners, polish and finger prints. It is important to note that fingerprints and other marks can leave a permanent stain on plated finishes. To avoid this, give the face a quick wipe with denatured alcohol on a soft cloth BEFORE lighting the fireplace. Never clean the door when it is hot. Do not use other cleaners as they may leave a residue, which can become permanently etched into the surface.

FIRE EXTINGUISHER AND SMOKE DETECTION:

All homes with a solid fuel burning stove should have at least one fire extinguisher in a central location known to all in the household and a smoke detection devise in the room containing the stove. If it sounds the alarm, correct the cause but do not deactivate. You may choose to relocate the smoke detection devise within the room; DO NOT REMOVE THE SMOKE DETECTOR FROM THE ROOM.

4

Image 4
Contents Wood Stove Table of Contents Safety Precautions Operating Instructions First StartCreosote ITS Formation and Removal Helpful Hints Worth Repeating What type of wood is best to use as firewood? What can cause a poor draft? 1200 Air Flow Path Specifications Capacity Feet3 0.0708 meter3 Approximate heating area † From front of unit to edge of floor protection Maintain These Minimum Clearances to Unshielded Combustibles 1700 Freestanding Clearance to Combustibles 1200 Insert Dimensions 1200 Freestanding Flat Top Dimensions 1700 Freestanding Flat Top Dimensions 1200 Freestanding with Fan Kit Dimensions Installation Bolts to removeInstalling Heat Shield Recommended Height for Flue Pipe Chimney Through Wall Method a Roof Clearances Shield if required Installation into a masonry chimney Venting Outside AIR Insert Installation into existing fireplace with Hearth Metal TAG this Fireplace has Been Before starting this type of installation 3D of Dimensions needed from Fireplace Insert Install into a Zero-Clearance Fireplace Total Bricks Model 1700 Brick Placement Do not USE Door if Glass is Broken Installation of Ceramic Baffle Back View of Freestanding Unit with Fan Kit Removal of right pod This will keep the trim tight Parts List Parts List Parts Diagram Parts Diagram Pedestals & Legs Parts Diagram Fireplace Insert Warranty Limited Five 5 Year Warranty Limited One 1 Year WarrantyExclusions and Limitations Warranty Installation Data Sheet

1700, 1200 specifications

The Enviro 1200 and 1700 are innovative solutions in the world of air treatment and environmental control. Designed to cater to industrial and commercial needs, these models are pivotal in enhancing air quality and promoting energy efficiency.

One of the main features of the Enviro 1200 is its advanced filtration system. It utilizes a multi-stage filtration process that includes pre-filters, HEPA filters, and activated carbon filters. This combination ensures the capture of particulate matter, volatile organic compounds (VOCs), and other airborne contaminants, providing cleaner and healthier air. The Enviro 1700, while similar in filtration capabilities, boasts a larger capacity, making it suitable for bigger spaces or industrial applications.

Both models incorporate smart sensor technologies that monitor air quality in real-time. These sensors provide data on pollutant levels, allowing for dynamic adjustments to the filtration strength. This not only optimizes performance but also reduces energy consumption, making the Enviro series both eco-friendly and cost-effective. The adaptive response of these systems ensures that users always breathe cleaner air without unnecessary energy expenditure.

Another defining characteristic of the Enviro 1200 and 1700 is their user-friendly interface. These units are designed with digital controls, allowing for easy programming and monitoring. Users can set specific operating schedules and track air quality trends over time. Additionally, both models come equipped with WiFi connectivity, enabling remote control via a smartphone app. This feature allows users to adjust settings or receive alerts about air quality levels from anywhere.

In terms of durability, both the Enviro 1200 and 1700 are constructed with high-quality materials that ensure long-lasting performance. They are designed to operate quietly, reducing the noise levels often associated with air treatment systems. This makes them suitable for a range of environments, from offices and homes to industrial settings.

In summary, the Enviro 1200 and 1700 stand out in the air treatment market due to their state-of-the-art filtration, smart technology integration, and user-centric design. These features, combined with their robust build quality, make them a reliable choice for anyone looking to improve air quality while maintaining energy efficiency.