ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical cord should be connected to a standard 220-240 volts (2.0-2.3 Amps), 50 hertz electrical outlet and also must be accessible. If this power cord should become damaged, a replacement power cord must be purchased from the manufacturer or a qualified ENVIRO dealer. Be careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges. This unit’s maximum power requirement is 525 watts.

GLASS: Do not abuse the glass by striking or slamming the door. Do not attempt to operate the stove with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an ENVIRO dealer. Do not attempt to open the door and clean the glass while the unit is in operation or if glass is hot. To clean the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner, or take a damp paper towel and dip into the fly ash. This is a very mild abrasive and will not damage the glass.

KEEP ASH PAN FREE OF RAW FUEL. DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN. A fire in the ash pan may occur.

INSTALLATION: Contact your local building or fire official to obtain a permit and any information on installation restrictions and inspection requirements for your area.

Be sure to maintain the structural integrity of your home when passing a vent through walls, ceilings, or roofs. It is recommended that the unit be secured into its position in order to avoid any displacement. This appliance must be installed on a floor with an adequate load bearing capacity. If an existing construction doesn’t meet these prerequisite suitable measures (e.g. load distributing plate) must be taken to achieve it.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

FRESH AIR: Outside Fresh Air connection is optional. Fresh Air must be connected to all units installed in “Air Tight Homes” or where required by local codes.

Consider all large air moving devices when installing your unit and provide room air accordingly. NOTE: Extractor fans when operating in the same room or space as the appliance, may cause problems. Limited air for combustion may result in poor performance, smoking and other side effects of poor combustion.

The stove’s exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure. It is very important to ensure that the exhaust system be sealed and airtight. The ash pan and viewing door must be locked securely for proper and safe operation of the pellet stove.

Do not burn with insufficient combustion air. A periodic check is recommended to ensure proper combustion air is admitted to the combustion chamber. Setting the proper combustion air is achieved by adjusting the slider damper located on the left side of the stove.

Minor soot or creosote may accumulate when the stove is operated under incorrect conditions such as an extremely rich burn (black tipped, lazy orange flames).

If you have any questions with regards to your stove or the above-mentioned information, please feel free to contact your local dealer for further clarification and comments.

SINCE SHERWOOD INDUSTRIES LTD. HAS NO CONTROL OVER THE INSTALLATION OF YOUR STOVE, SHERWOOD INDUSTRIES LTD. GRANTS NO WARRANTY IMPLIED OR STATED FOR THE INSTALLATION OR MAINTENANCE OF YOUR STOVE. THEREFORE, SHERWOOD INDUSTRIES LTD. ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).

SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE

5

Image 5
Contents Evolution Table of Contents Store pellets at least 36 1 m away from the pellet stove IntroductionUSE of Cordwood is Prohibited by LAW Safety Warnings & RecommendationsSafety Warnings & Recommendations Hearth Pad SpecificationsUnit Overheated Operating InstructionsManual Mode Efficient Flame Special NotesTools Required to Clean Unit Routine Cleaning and MaintenanceDoor Glass Cleaning 2-3 days Burner POT and Liner 2-3 daysASH PAN weekly ASH PAN and Door Gaskets weeklyPellet Fuel in ASH PAN Exhaust Passages biannuallyCleaning Plated Surfaces Post Season CLEAN-UPDoor Glass Replacement Control Board Error MessagesName of Owner Address Installation Data Sheet

50-1573 specifications

The Enviro 50-1573 is an innovative and eco-friendly solution aimed at addressing the growing needs of businesses and consumers alike. This product is designed with a focus on sustainability without compromising on performance or functionality.

One of the most notable features of the Enviro 50-1573 is its advanced energy efficiency technology. It uses state-of-the-art mechanisms to minimize energy consumption, making it an ideal choice for environmentally conscious users. Its design incorporates high-efficiency components that significantly reduce the carbon footprint while still delivering optimal performance. This efficiency not only helps the environment but also results in cost savings for users.

The Enviro 50-1573 is built using sustainable materials, which is a crucial characteristic for modern consumers. The use of recycled and non-toxic materials ensures that the product is safe for both the user and the planet. Manufacturers prioritize the lifecycle impact of their products, ensuring that they are designed to be recyclable or biodegradable at the end of their use.

In terms of technology, the Enviro 50-1573 incorporates smart features that enhance user experience. It includes an intuitive control system that allows users to monitor performance and make adjustments easily. This technology can be further integrated with mobile applications, allowing for remote operation and real-time tracking of energy usage and efficiency metrics.

Safety is another key characteristic of the Enviro 50-1573. It is designed with multiple safety protocols to protect users and surrounding environments, ensuring peace of mind during operation. These protocols include overload protection and automatic shut-off features, which help to prevent accidents and energy waste.

Moreover, the Enviro 50-1573 offers versatility, as it can be used in a variety of settings, from residential to commercial applications. Its streamlined design allows it to fit seamlessly into any environment without being obtrusive.

In conclusion, the Enviro 50-1573 stands out in the market for its commitment to sustainability, energy efficiency, and user-friendly technology. By prioritizing eco-friendliness alongside cutting-edge features, it meets the demands of today’s environmentally aware consumers while providing unwavering performance. Whether for home or business use, the Enviro 50-1573 represents a forward-thinking approach to products designed for a sustainable future.