Harman Stove Company Super Magnum Coal Stoker Stove When This Room Heater Is Not Properly

Page 2

Super-Magnum Coal Stoker Stove

Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you have become part of a long standing family committed to meeting the heating needs of consumers with the most distinctive, powerful and responsible home heating products available.

The Super-Magnum has huge features in an elegant package, giving you 5000 to 100,000+ BTU when you need it, automatically. You need only set your desired room temperature, keep the hopper full, and the ash pan empty. With the Super- Magnum, you will notice even heat throughout your zone and a level of convenience you never thought possible. The Super-Magnum takes advantage of Harman’s 30+ years of stove design, technology and manufacturing. This high output stove has Super-Smart controls coupled with minimal maintenance. Output is managed by a microprocessor that senses the room temperature and the fire temperature with two thermistor probes and then determines the best feed rate for your heating demand. The platinum combination is Harman’s Patented Verti-FlowTMFeeder system, and ESP Control which have been developed to their highest state. These features work together to allow amazing heat output with little regard for fuel quality.

We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Harman Home Heating.

 

 

 

 

 

 

 

 

 

 

 

 

 

Super Magnum Coal Stoker Stove

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Poêle à charbon Super Magnum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Room Heater- Coal Burning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appareil de chauffage d’appoint au charbon

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Report #/ Raport # 135-S-24-6.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tested to / Testé à: UL1482,

Serial No.

008

 

 

 

Rapport no 135-S-24-6.2

 

 

 

 

 

 

 

 

 

 

 

 

UL 391, and ULC S627-00

№ de série

 

 

 

Conforme à UL 1482, UL 391 et ULC S627-00

 

 

 

 

 

 

 

 

 

 

 

 

Test Date: July 2009

 

 

 

 

 

Date d’essai: Juillet 2009

 

 

 

 

 

 

 

 

 

 

 

 

Approved For Use in Mobile/Manufactured Homes- USA ONLY

Homologué pour les maisons mobiles et préfabriquées - É.-U. SEULEMENT

 

 

 

 

 

 

 

 

 

 

 

 

Cet appareil est également homologué pour être installé dans un atelier.

Harman Home Heating, A division of

 

This appliance is also approved for installation into a shop.

 

mode d’emploi du fabricant et les codes locaux. En l’absence de codes

 

Install and use only in accordance with manufacturer’s installation

 

 

 

 

 

 

 

 

 

 

 

 

“PREVENT HOUSE FIRES”

 

 

«ÉVITEZ LES INCENDIES DE MAISON»

 

Hearth & Home Technologies, Inc.

 

 

 

N’installez et n’utilisez cet appareil que selon le mode d’installation et le

 

codes, installation must meet minimum requirements of NFPA 211

la norme NFPA 211 aux É.-U. Voir dans les recommandations du

 

 

 

 

 

 

 

 

 

 

 

 

and operation instructions and local codes. In absence of local

locaux, l’installation doit au minimum être conforme aux exigences de

 

 

352 Mountain House Road

 

 

in USA. Refer to manufacturer’s instructions and local codes for

fabricant et dans les codes locaux les précautions quant au passage

 

 

 

 

precautions required for passing chimney through a combustible

d’une cheminée à travers un mur ou un plafond combustible.

 

 

Halifax, PA 17032

 

 

 

wall or ceiling.

 

 

 

MISE EN GARDE POUR LES MAISONS PRÉFABRIQUÉES : (É.-U.

 

 

 

 

 

install appliance in a sleeping room. An outside air inlet must be

Une arrivée d’air de combustion extérieur doit être prévue. L’intégrité

 

 

 

 

 

 

 

 

 

 

 

 

WARNING FOR MANUFACTURED HOMES: (US Only) Do not

seulement) N’installez pas cet appareil dans une chambre à coucher.

 

 

www.harmanstoves.com

 

 

walls, and ceiling must be maintained.

 

 

structurelle du plancher, des murs et du plafond de la maison

 

 

 

 

 

 

Voir dans les recommandations du fabricant et dans les codes locaux

 

 

 

 

 

 

 

 

 

 

 

 

provided. The structural integrity of the manufactured home’s floor,

préfabriquée doit être maintenue.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refer to manufacturer’s instructions and to local codes for

les précautions quant au passage d’une cheminée à travers un mur

 

 

 

 

 

 

 

 

 

 

 

 

precautions required for passing chimney through a combustible

 

 

 

 

 

 

 

 

 

 

 

 

ou un plafond combustible.

 

 

 

 

 

 

 

 

 

 

 

 

 

wall or ceiling.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Le tuyau de raccord à la cheminée doit être d’un diamètre de 15,25

 

 

 

 

 

 

 

 

 

 

 

 

Flue connector pipe must be 6” diameter, minimum 24 MSG blue

 

 

 

 

 

 

 

 

 

 

 

 

cm (6 po), au minimum en acier bleu 24 MSG. La cheminée doit être

 

 

 

 

 

 

 

 

 

 

 

 

steel. Chimney must be factory built 103HT or masonry construction.

en métal 103HT d’usine ou construite en maçonnerie.

 

 

 

 

 

 

 

 

 

 

 

 

DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE

NE RELIEZ PAS CE POÊLE À UNE CHEMINÉE QUI SERT POUR

 

 

 

 

 

 

 

 

 

 

 

 

SERVING ANOTHER APPLIANCE.

 

 

UN AUTRE APPAREIL.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR USE wITH ANTHRACITE “RICE” COAL ONLY Do not burn

IL NE FAUT UTILISER QUE DE L’ANTHRACITE «RICE», pas du

 

 

 

 

 

 

 

 

 

 

 

 

wet coal.

 

 

 

charbon mouillé.

 

 

When This Room Heater Is Not Properly

DO NOT Overfire - If Heater or chimney connector glows, you

Ne chauffez pas TROP.

Si l’appareil ou le raccord de cheminée

Input Rating Maximum: 7.75 lb. Fuel/hr.

 

 

Consommation maximale : 7,75 lb de carburant/heure

Installed, a House Fire May Result.

To

are overfiring.

 

 

 

rougit, c’est que le feu est trop puissant.

 

Route power cord away from unit.

 

 

Éloignez le cordon électrique de l’appareil.

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Rating: 115 VAC, 60 Hz,3.1 AMPS

 

 

Courant alternatif de 115 V, 60 Hz, 3,1 ampères

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reduce

The

Risk

 

Of

Fire,

Follow

The

servicing. For further instruction, refer to owner’s manual.

DANGER: Risque de décharge électrique. Débranchez la prise avant

 

Ne remplacez le verre que par du verre céramique de 5 mm à obtenir

 

 

 

 

 

 

 

 

 

 

 

 

DANGER: Risk of electrical shock. Disconnect power supply before

tout entretien. Pour plus de détails, consultez le mode d’emploi.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation

Instructions.

Contact

Replace glass only with 5mm ceramic, available from your dealer.

passage d’air sous l’appareil.

 

airflow under the appliance.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appliance must be installed with the legs attached. Do not obstruct

de votre détaillant.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L’appareil doit être installé avec ses pieds fixés. N’obstruez pas le

Local

Building

Or

Fire

Officials

About

gasoline, drain oil or other flammable liquids.

 

 

d’essence, d’huile de vidange ni aucun autre liquide inflammable.

Restrictions

And

Installation

Inspection

DANGER: Risk of Fire or Explosion - Do not burn garbage,

DANGER: Risque d’incendie ou d’explosion. Ne brûlez pas d’ordures,

Do not operate with flue draft exceeding -0.080 in water

de colonne d’eau.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: Risk of Fire

 

 

MISE EN GARDE: Risque d’incendie.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N’utilisez pas le poêle avec un conduit de cheminée dépassant -0,080

Requirements In Your Area.

 

 

 

Do not operate with fuel loading or ash removal doors open.

 

 

 

ouvertes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

column.

 

 

 

N’utilisez pas le poêle lorsque les portes du foyer et du cendrier sont

 

 

 

 

 

 

 

 

 

 

 

 

Do not store fuel or combustibles within marked clearances.

Gardez le carburant et les matériaux combustibles en dehors des

 

 

 

 

 

 

 

 

 

 

 

 

Inspect and clean flues and chimney regularly.

 

dégagements prescrits.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inspectez et nettoyez fréquemment les conduits et la cheminée.

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION: HOT wHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN AND CLOTHING AwAY.

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. KEEP FURNISHINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

AND OTHER COMBUSTIBLE MATERIALS A CONSIDERABLE DISTANCE AwAY FROM THIS APPLIANCE.

 

 

 

 

 

 

 

 

 

 

 

 

 

ATTENTION: CHAUD LORS DU FONCTIONNEMENT. NE TOUCHEZ PAS L’APPAREIL.GARDEZ LES

 

 

 

 

 

 

 

 

 

 

 

 

 

ENFANTS ET LES VÊTEMENTS ÉLOIGNÉS. TOUT CONTACT PEUT ENTRAÎNER DES BRÛLURES DE

 

 

 

 

 

 

 

 

 

 

 

 

 

LA PEAU. RÉFÉREZ-VOUS À LA PLAQUE SIGNALÉTIQUE ET AU MODE D’EMPLOI. GARDEZ LE

 

 

 

 

 

 

 

 

 

 

 

 

 

MOBILIER ET LES AUTRES MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART DE L’APPAREIL.

 

 

 

 

 

 

 

 

 

 

 

 

CLEARANCE TO COMBUSTIBLES / DISTANCES MINIMALES DE SECURITE:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parallel

 

Inches Millimeters

Floor Protection

Inches

Millimeters

 

 

 

 

 

 

 

 

 

 

 

 

Installation

 

Requirements

 

 

 

 

 

 

 

 

 

 

 

 

A Back Wall To Hopper / Entre mur arriereet l’appareil

2

51

G Sides / Côtés

8

203

 

 

 

 

 

 

 

 

 

 

 

 

B Side Wall To Unit / Entre mur lateral et l’appareil

24

610

H Front- from glass/Devant, par rapport au verre 18

457

 

 

 

 

 

 

 

 

 

 

 

 

C Back Wall To Flue Pipe / Entre tuyau et le mur arriere

17

432

J

Rear / Arrière

12

305

 

 

 

 

 

 

 

 

 

 

 

 

D Side Wall To Flue Pipe / Entre tuyau et le mur lateral

34

864

Floor protection must be a non-combustible material, and

 

 

 

 

 

 

 

 

 

 

 

 

A C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

must also be placed under any horizontal sections of chimney

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connector pipe, extending 2” (51mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J

beyond the measurement of the pipe.

 

 

 

 

 

 

 

 

 

 

 

 

 

D

 

F

 

 

Pour protéger le plancher, il faut sous

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

E

G

G

le poêle un matériau non combustible,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

qui doit aussi être placé sous les

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

parties horizontales du tuyau de

 

 

 

 

 

 

 

 

 

 

 

 

Corner

 

Inches

Millimeters

 

 

raccord à la cheminée et s’étendre à

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

51 mm (2 po) au-delà de la mesure du

 

 

 

 

 

 

 

 

 

 

 

 

Installation

 

 

H

 

 

 

 

 

 

 

 

 

 

 

 

E Walls to Unit Body / Entre mur adjacent et l’appareil

15

381

 

tuyau.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F Walls to Flue Pipe / Entre tuyau et le mur adjacent

24

610

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2009 2010 2011 JAN

Date of Manufacture / Date de fabrication:

 

 

 

FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P.N. 3-90-02700

Fabriqué par: Harman Home Heating 352 Mountain House Road, Halifax PA 17032 (É.-U.)

IGN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

Do Not Burn Wet Coal!

3-90-02702R4_08/12

Image 2
Contents Installation and Operation Super-Magnum Coal Stoker StoveInstallation When This Room Heater Is Not ProperlyInstalled, a House Fire May Result Restrictions InstallationTable of Contents Mobile Home Approved This appliance is also approved for installation in a shop1Listing and Code Approvals 2Special Warnings and Notes Wet Coal Prevent Rust & CorrosionRoom Sensor Location 3Getting StartedAppliance Location Component Locations Pre- Use Check List Fire Risk4Dimensions & Clearances Floor Protection ParallelCorner RequirementsDraft Chimney Connectors5Chimneys and Venting Wall Pass-thrusChimney 3-foot, 2-foot, 10 foot ruleVenting to a Masonry Chimney Installing to a Prefabricated ChimneyExisting Masonry Chimneys Venting to a Masonry Fireplace ChimneyDraft Test Procedure Mobile Home Installation 6Mobile Home7Appliance Set-Up Outside Air AttachmentAir Filter Leveling the ApplianceOptional Heat Transfer Kit Optional Decorative Tile KitRoom Sensor Installation Optional Door Trim KitFuel Specifications ESP Exhaust Sensing ProbeStatus Light Error Messages Circuit BoardTemperature Dial Feed Rate AdjustmentMode Selection Blower Speed AdjustmentStarting Your First Fire Fire CharacteristicsBefore Your First Fire Troubleshooting Symptom Possible Cause Corrective ActionQuick Reference Maintenance Chart 10Service & MaintenanceShut-down Procedure Soot Formation and Need For RemovalGeneral Maintenance Procedures Door Glass Hopper Air Filter Frequency Monthly By UserFirebox Chimney Chimney ConnectorMotors and Components Feed MotorFines Scraper- in feeder Distribution BlowerESP- Exhaust Sensing Probe 11Reference Materials Supermagnum Coal Stoker #Service Parts 90-02700-1 Part number list on followingStocked at Depot 20 x 1/2 Alloy Steel Black Oxide Button Head Cap Screw At Depot Stocked#44 Motor Mount Assembly Limited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifService & Maintenance Log 90-02702R408/12 Do Not Burn Wet Coal Signature of Boxer Proudly Printed On 100% Recycled Paper

Super Magnum Coal Stoker Stove specifications

The Harman Stove Company Super Magnum Coal Stoker Stove is a remarkable heating solution that combines efficiency, reliability, and advanced technology to provide optimal warmth for your home. This stove is specifically designed to burn anthracite coal, a high-quality fuel that offers many advantages in heating.

One of the main features of the Super Magnum is its impressive heat output. It is capable of producing an astounding 140,000 BTUs per hour, making it suitable for larger spaces and even whole-home heating. This powerful output ensures that your environment stays warm and comfortable, even on the coldest winter nights.

The construction of the Super Magnum is another highlight. Built from high-quality steel, it is designed to withstand the rigors of continuous use. The stove features a large ash pan, which simplifies the maintenance process. With its easy-open access, homeowners can replace the ash quickly, ensuring that the appliance operates smoothly and efficiently.

In addition to its durable build, the Harman Super Magnum utilizes cutting-edge technologies to enhance performance. One of these technologies is the TWICE® System, which manages the internal combustion process to maximize heat output while minimizing emissions. This advanced system helps in maintaining a clean burn, making it an environmentally friendly option compared to traditional wood-burning stoves.

The stove also features a unique stoker system that automatically feeds coal into the burning chamber. This automated process not only ensures consistent heating but also reduces the need for constant monitoring. Users can set the desired temperature, and the stoker will adjust the fuel supply accordingly, allowing for a hassle-free heating experience.

Additionally, the Super Magnum is equipped with an integrated blower system that helps distribute warmth evenly throughout the space. The adjustable blower allows for customization based on the space's needs, ensuring that every corner of your home is comfortably heated.

Overall, the Harman Stove Company Super Magnum Coal Stoker Stove stands out as a powerful and technologically advanced heating solution. With its robust construction, impressive BTU output, automatic fuel feeding system, and advanced combustion management, it is an excellent option for those looking to efficiently heat their homes using coal. The Super Magnum not only provides comfort but also peace of mind, knowing that you have a reliable heating source ready to take on the cold season.