Harman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner System manual

Page 21

ASSEMBLY

PRIMARY AIR ADJUSTER

Your FireLuxe gas stove was shipped from the factory equipped for the fuel type indicated on the rating plate that is attached to the rear of the stove and the pri-

mary burner air adjuster was set at the factory at the rec- ommended position for that fuel. If you will be using the alternate fuel please see the instructions included with the optional fuel conversion kit. This includes in- structions for the proper setting for the primary air ad- juster.

The recommended setting for propane is the fully-open position. This corresponds to the adjuster screw fully backed out. The recommended setting for natural gas is the fully-closed position. This corresponds to the ad- juster screw fully screwed in.

Making small adjustments to the primary air setting will let you adjust the way the flames look for your particu- lar installation. See the reference to primary air adjust- ment in the section below that discusses the air inlet and exhaust outlet restrictors.

AIR INLET AND EXHAUST OUTLET RESTRICTORS

PRIMARY AIR ADJUSTER SCREW

The FireLuxe is equipped with externally adjustable restrictors for both the inlet air and the exhaust outlet. This makes it possible to fine tune the direct vent system for the specific conditions of your installation. The recommended settings are keyed to the specific details of your venting configuration.

To access the restrictor adjustment guide plates, you must first remove the access plate. Looking at the stove from the front, this plate is located on the upper left rear of the stove. If you have the optional blower, the access plate also contains the blower speed control. Remove the single fastener that secures the access plate. Set the plate aside (or if the blower is installed, let the plate hang on the wiring). Next remove the heat shield. This is held in place with a single fastener located at the lower front corner of the shield. With the fastener removed, tilt the heat shield as needed and remove. Refer to the illustrations below.

FASTENER

HEAT SHIELD

FASTENER

ACCESS COVER

21

Image 21
Contents Installation & Operating Manual Page Table of Contents Important Safety Information Main Burner SpecificationsMinimum Clearances to Combustible Construction InstallationRequirements for the Commonwealth of Massachusetts Venting Inlet AIR Exhaust Natural GAS Venting Propane LP GAS Venting Venting Into AN Existing Masonry or Class a Chimney Vent Terminal Clearances Unpacking and Placing the Fireluxe AssemblyLogs and Embers Right Front LOG Left Front LOGAssembly Brass Diffuser Ring Front by aligning Outer edges withBattery Installation or Replacement GAS Connection Fastener Heat Shield Access Cover Primary AIR AdjusterAssembly For Your Safety Read Before Lighting Lighting and OperationLighting Instructions Main Burner Automatic Ignition To Turn OFF GAS to Main Burner Manual IgnitionLighting Instructions Cooking Burner To Turn OFF GAS to Cooking BurnerPilot and Main Burner Operation Cooking Burner OperationPilot Flame Adjustment Remote Control Handset Operation and ProgrammingHandset SET OFF Down Maintenance Cleaning the Glass Battery ReplacementReplacing the Glass Inspecting the Venting Cleaning the LOGS, Burner and FireboxAIR Flow Cooking Burner SystemParts List Harman Gold Warranty Harman Stove Company 352 Mountain House Road HALIFAX, PA