•A Type 1 compatible cylinder with a Type 1 cylinder valve has a
•The cylinder must be arranged in an upright position for vapor withdrawal. It must also include a collar to protect the cylinder valve. A safety relief device having direct communication with the vapor space of cylinder must be provided. This will expel high pressure gas if the cylinder is over filled or overheated which could result in fire or explosion.
•All refillable L.P. gas cylinders used with this appliance shall be constructed and marked in accordance with the Specifications for L.P. Gas Cylinders of the U. S. Department of Transportation (DOT) or the National Standard of Canada,
•Read labels on the L.P. Gas Supply Cylinder.
•New refillable cylinders are always shipped empty for safety.
•Allow only qualified L.P. gas dealers to fill or repair your refillable L.P. gas supply cylinder.
•Inform the gas dealer if it is a new or used cylinder to be filled.
•Caution the gas dealer not to overfill the cylinder.
•After filling, have the gas dealer check for leaks and to see that the relief valve remains free to function.
CAUTION
Have the gas dealer weigh the cylinder after filling to ensure that the cylinder is not over filled.
Hose and Regulator
The Type 1 connection system has the following features:
1.The system will not allow gas to flow until a positive connection has been made.
NOTE: The cylinder control valve must be turned off before any connection is made or removed.
2.The system has a thermal element that will shut off the flow of gas in the event of a fire.
3.The system has a flow limiting device which, when activated, will limit the flow of gas to 10 cubic feet per hour.
4.NEVER use stove without leak testing this connection.
WARNING
•DO NOT attempt to adjust the regulator as this could create a situation causing personal injury or property damage.
The pressure regulator and hose assembly with the Type 1 fitting supplied with the appliance must be used. Do not use another hose and regulator assembly other than the one supplied with the stove or a Coleman® replacement pressure regulator assembly. The pressure regulator and hose assembly provided is factory set at an outlet pressure of 11 inches water column (1/2 psi).
•Keep the small vent hole in the regulator clean of dirt and debris (see item [G], Fig. 21).
•Consult your L.P. gas dealer if you think the regulator is not working properly.
Transporting the Refillable Cylinder
•Transport only one refillable cylinder at a time.
•Transport the cylinder in an upright and secure manner with a control valve turned off and the cap in place.
•DO NOT transport the cylinder in the passenger compartment, unless you have an open window ventilation.
•DO NOT leave the cylinder in direct sunlight or in a high heat area such as a closed car trunk. High heat areas could cause the relief valve to vent gas.
•Use a cylinder cap on the cylinder valve outlet during transport and when the cylinder is not connected to the stove.
•Keep the cylinder valve closed when not in use.
•Take the cylinder directly home after it has been filled.
WARNING
Handle a full cylinder with care. Gas is under high pressure.
DANGER
•NEVER store a spare L.P. gas supply cylinder in the vicinity of any heat producing appliance.
•NEVER fill the cylinder beyond 80% full.
Failure to follow this information exactly could result in an explosion and/or fire causing death or serious injury.