Breckwell P4000 Thermostat Installation, Optional Thermostat, Millivolt Thermostat is Required

Page 14

14

THERMOSTAT INSTALLATION

OPTIONAL THERMOSTAT

A thermostat may help you maintain a constant house temperature automatically. A millivolt thermostat is required. A fixed wall mount or Breckwell’s hand held model can be used. The control panel can be set up two ways to operate your stove in thermostat mode.

NOTE: YOUR THERMOSTAT SHOULD BE INSTALLED BY AN AUTHORIZED DEALER OR SERVICE PERSON.

THERMOSTAT INSTALLATION

A MILLIVOLT THERMOSTAT IS REQUIRED.

Unplug stove from power outlet.

Remove control board from stove.

The two thermostat wires connect to the terminal block on the lower left side of the back of the control board.

(See figure 14)

Insert the wires in the terminal side and tighten the two screws.

MODES

TO SWITCH BETWEEN ANY OF THE THREE MODES THE STOVE MUST BE SHUT OFF, THE NEW MODE SELECTED, AND THE STOVE RESTARTED.

MANUAL MODE

In this mode the stove will operate only from the control panel as detailed in the “OPERATION” section of this owner’s manual.

HIGH/LOW THERMOSTAT MODE

When engaged in this mode the stove will automatically switch between two settings. When warm enough, it will switch to the #1 or low setting. The room air blower will also slow to its lowest speed.

The Heat Level Advance setting on the bar graph will stay where it was initially set. When the house cools below the thermostat setting, the stove will switch to the feed rate of the heat level advance setting.

ON/OFF THERMOSTAT MODE

In this mode when the home is warm enough the stove will shut off. The fans will continue to run until the stove cools.

When the home cools below the thermostat setting, the stove will automatically restart and run at the last feed rate setting.

NOTE: When in “high/low” or “on/off” thermostat mode –

Do not operate the stove higher than the #3 setting.

Set damper control rod approximately ½” to ¾” out. This will vary depending on elevation and weather conditions. Observe stoves operation and adjust damper as necessary.

FIGURE 14

Image 14
Contents Vermont Introduction Important InformationSafety Precautions Table of Contents Preparation InstallationSpecifications ClearancesVenting When Outside AIR is not UsedCombustion AIR Supply Horizontally Through Wall refer to Figure P4000 InstallationEquivalent Vent Length EVL Vertically with NEW Chimney System Refer to Figure Vertically Into Existing Chimney SystemInstallation Through Side of Masonry Chimney Vertically Into Existing Masonry FireplaceElectrical Installation Special Mobile Home Requirements Operation Building a Fire Proper FuelPRE-START-UP Check Hotrod Automatic FirestarterSafety Features Breckwell Maintenance ToolShutdown Procedure RE-STARTING a Warm StoveOptional Thermostat Thermostat InstallationThermostat Installation Millivolt Thermostat is RequiredPlease Read this ASH Disposal MaintenanceASH Removal Vacuum USECleaning BlowersChimney Cleaning Daily Weekly Annually or per TonPossible Causes Troubleshooting GuideStove Shuts OFF and the # 2 Light Flashes Stove Shuts OFF and the # 3 Light Flashes Smoke Smell Coming Back Into the Home Stove Feeds PELLETS, but will not IgnitePossible Causes Possible Remedies Convection Blower Shuts OFF and Comes Back onTroubleshooting Guide Troubleshooting Guide Smoke Smell or Soot BUILD-UP High Limit Switch Keeps TrippingHeat Level Setting P4000 Digital Circuit Board Timing RatesElectrical Diagram Replacement Parts BurnpotLifetime Limited Warranty