When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money by enabling you to solve simple problems yourself. Problems can be caused by to only five factors: 1) poor fuel; 2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You can usually solve those problems related to 1 and 2. Your dealer can solve problems relating to 3, 4 and 5. Refer to figures 20, 21 and 22 to help locate indicated parts.

STOVE SHUTS OFF AND THE # 2 LIGHT FLASHES

Possible Causes:

Possible Remedies: (Unplug stove first when possible)

 

 

 

1.

Airflow switch hose or stove attachment pipes for hose are

Unhook air hose from the air switch and blow through it. If air flows

 

blocked.

freely, the hose and tube are fine. If air will not flow throw the hose,

 

 

use a wire coat hanger to clear the blockage.

 

 

 

2.

The air inlet, burnpot, interior combustion air chambers,

Follow all cleaning procedures in the maintenance section of the

 

combustion blower, or exhaust pipe are blocked with ash or

owner’s manual.

 

foreign material.

 

 

 

 

3.

The firebox is not properly sealed.

Make sure the door is closed and that the gasket is in good shape.

 

 

If the ash door has a latch, make sure the ash door is properly

 

 

latched and the gasket is sealing good. If the stove has just a small

 

 

hole for the ashes to fall through under the burnpot, make sure the

 

 

slider plate is in place to seal off the firebox floor.

 

 

 

4.

Vent pipe is incorrectly installed.

Check to make sure vent pipe installation meets criteria in owner’s

 

 

manual.

 

 

 

5.

The airflow switch wire connections are bad.

Check the connectors that attach the gray wires to the air switch.

 

 

 

6.

The gray wires are pulled loose at the Molex connector on the

Check to see if the gray wires are loose at the Molex connector.

 

wiring harness.

 

 

 

 

7.

Combustion blower failure.

With the stove on, check to see if the combustion blower is running.

 

 

If it is not, you will need to check for power going to the combustion

 

 

blower. It should be a full current. If there is power, the blower is

 

 

bad. If there is not, see #8.

 

 

 

8.

Control board not sending power to combustion blower.

If there is no current going to the combustion blower, check all wire

 

 

connections. If all wires are properly connected, you have a bad

 

 

control board.

 

 

 

9.

Control board not sending power to air switch.

There should be a 5-volt current (approximately) going to the air

 

 

switch after the stove has been on for 30 seconds.

 

 

 

10.

Air switch has failed (very rare).

To test the air switch, you will need to disconnect the air hose from

 

 

the body of the stove. With the other end still attached to the air

 

 

switch, very gently suck on the loose end of the hose (you may want

 

 

to remove the hose entirely off the stove and the air switch first and

 

 

make sure it is clear). If you hear a click, the air switch is working.

 

 

BE CAREFUL, TOO MUCH VACUUM CAN DAMAGE THE AIR

 

 

SWITCH.

 

 

 

Image 19
Contents Vermont Important Information IntroductionSafety Precautions Table of Contents Clearances InstallationSpecifications PreparationCombustion AIR Supply When Outside AIR is not UsedVenting Equivalent Vent Length EVL P4000 InstallationHorizontally Through Wall refer to Figure Vertically Into Existing Chimney System Vertically with NEW Chimney System Refer to FigureVertically Into Existing Masonry Fireplace Installation Through Side of Masonry ChimneySpecial Mobile Home Requirements Electrical InstallationOperation Hotrod Automatic Firestarter Proper FuelPRE-START-UP Check Building a FireRE-STARTING a Warm Stove Breckwell Maintenance ToolShutdown Procedure Safety FeaturesMillivolt Thermostat is Required Thermostat InstallationThermostat Installation Optional ThermostatPlease Read this Vacuum USE MaintenanceASH Removal ASH DisposalBlowers CleaningDaily Weekly Annually or per Ton Chimney CleaningStove Shuts OFF and the # 2 Light Flashes Troubleshooting GuidePossible Causes Stove Shuts OFF and the # 3 Light Flashes Convection Blower Shuts OFF and Comes Back on Stove Feeds PELLETS, but will not IgnitePossible Causes Possible Remedies Smoke Smell Coming Back Into the HomeTroubleshooting Guide Troubleshooting Guide Digital Circuit Board Timing Rates High Limit Switch Keeps TrippingHeat Level Setting P4000 Smoke Smell or Soot BUILD-UPElectrical Diagram Burnpot Replacement PartsLifetime Limited Warranty

P4000 specifications

The Breckwell P4000 is a pellet stove that combines efficiency, performance, and stylish design, making it an ideal choice for homeowners seeking an eco-friendly heating solution. With its robust construction and advanced technology, the P4000 stands out in a crowded market of heating appliances.

One of the key features of the Breckwell P4000 is its high heating capacity. Designed to heat spaces up to 2,200 square feet, it has a maximum output of 40,000 BTUs. This makes it suitable for both small and large rooms, providing a comfortable environment even in the coldest months. The stove also includes a large hopper capacity, able to hold up to 60 pounds of pellets, allowing for longer burn times without the need for constant refueling.

The P4000 is equipped with an advanced digital control panel. This user-friendly interface allows homeowners to easily adjust the thermostat and control the flame intensity, ensuring an optimal heating experience. Additionally, it features an automatic igniter for hassle-free start-up, allowing users to ignite their stove with the push of a button.

Efficiency and environmental performance are cornerstones of the Breckwell P4000's design. The stove boasts an impressive efficiency rating of up to 87%, meaning that minimal heat is lost during operation. This efficiency not only leads to lower heating bills but also reduces the environmental impact, as pellet stoves are considered a renewable energy source.

The P4000 also emphasizes safety, featuring a list of safety controls including a heat sensor and an automatic shut-off function. This ensures peace of mind for users, as it reduces the risk of overheating or fire hazards.

Another appealing aspect of the Breckwell P4000 is its aesthetic versatility. The stove comes in various finishes, including traditional black and modern stainless steel, allowing it to seamlessly integrate into various home decors. Its compact design ensures it can fit into tight spaces while still delivering powerful heating performance.

In conclusion, the Breckwell P4000 pellet stove combines modern technology, high efficiency, and attractive design. Its powerful heating capabilities, user-friendly controls, and safety features make it an excellent choice for homeowners looking for a reliable and stylish heating solution. Whether for a cozy living room or an expansive open space, the P4000 is dedicated to providing warmth and comfort during the cold months.