Breckwell P24FS, P24I RE-STARTING a Warm Stove, If Stove Runs OUT of Pellets, Refueling

Page 17

OPERATION

17

RE-STARTING A WARM STOVE

If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held down for 2 seconds.

IF STOVE RUNS OUT OF PELLETS

The fire goes out and the auger motor and blowers will run until the stove cools. This will take 30 to 45 minutes. After the stove components stop running the “On/Off” and the BAR GRAPH lights stay on for 10 minutes.

After the 10 minutes the “3” light on the bar graph will flash and the “On/Off” light will go off.

To restart, refill hopper and press “Fuel Feed” button until pellets begin to fall into burnpot. Press “On/Off” button.

REFUELING

We recommend that you not let the hopper drop below ¼ full.

KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. DO NOT OVERFILL HOPPER.

BRECKWELL MAINTENANCE TOOL

A tool has been provided to help with the following functions:

FIGURE 20

a.Stirring pellets in hopper – unlike liquids in a tank, pellets do not drain evenly into the auger. Bridging across the opening can occur. Pellets can hang up on the sides of the hopper. Occasionally “stirring” the hopper can help.

NOTE: To help prevent bridging of pellets, common wax paper can be rubbed on the sidewalls and bottom of the hopper.

b.Cleaning heat exchanger tubes – see instructions in “CLEANING”.

c.Scrape ashes from burnpot.

SHUTDOWN PROCEDURE

Turning your Breckwell stove off is a matter of pressing the “On/Off” control panel switch. The green light will go out. The blowers will continue to operate until internal firebox temperatures have fallen to a preset level.

SAFETY FEATURES

a.Your stove is equipped with a high temperature thermodisc. This safety switch has two functions.

1.To recognize an overheat situation in the stove and shut down the fuel feed or auger system.

2.In case of a malfunctioning convection blower, the high-temperature thermodisc will automatically shut down the auger, preventing the stove from overheating.

NOTE: On some units, once tripped, like a circuit breaker, the reset button will have to be pushed before restarting your stove. On other units the thermodisk has no reset button and will reset itself once the stove has cooled. The manufacturer recommends that you call your dealer if this occurs as this may indicate a more serious problem. A service call may be required.

b.If the combustion blower fails, an air pressure switch will automatically shut down the auger.

NOTE: Opening the stove door for more than 30 seconds during operation will cause enough pressure change to activate the air switch, shutting the fuel feed off. Close the door and press “On/Off” button to continue operation of your stove.

Image 17
Contents Tradition Series P24 Important Information IntroductionSafety Precautions Table of Contents Specifications InstallationPreparation ClearancesCombustion AIR Supply When Outside AIR is not UsedVenting Rear View P24FSA Rear View P24IHorizontally Through Wall refer to Figure Freestanding InstallationEquivalent Vent Length EVL Vertically with NEW Chimney System Refer to a & 9b Vertically Into Existing Chimney System Vertically Into Existing Masonry Fireplace Installation Through Side of Masonry ChimneyAssembling the Flashing SET Insert InstallationsWhen Vent Pipe Extends to Chimney TOP AS a BUILT-IN Fireplace Special Mobile Home Requirements Electrical Installation Installation in to a Factory Built Metal Fireplace Operation PRE-START-UP Check Proper FuelBuilding a Fire Hotrod Automatic FirestarterShutdown Procedure Breckwell Maintenance ToolSafety Features RE-STARTING a Warm StoveThermostat Installation Thermostat InstallationOptional Thermostat Millivolt Thermostat is RequiredPlease Read this ASH Removal MaintenanceASH Disposal Freestanding Models ASH Disposal InsertVacuum USE CleaningBlowers Rear View P24FSRecommended Maintenance Schedule Chimney CleaningRemoval and Replacement of Broken Door Glass Daily Weekly Annually or per TonMaintenance Possible Causes Troubleshooting GuideStove Shuts OFF and the # 2 Light Flashes Stove Shuts OFF and the # 3 Light Flashes Possible Causes Possible Remedies Stove Feeds PELLETS, but will not IgniteSmoke Smell Coming Back Into the Home Convection Blower Shuts OFF and Comes Back onTroubleshooting Guide Troubleshooting Guide Heat Level Setting P24 High Limit Switch Keeps TrippingSmoke Smell or Soot BUILD-UP Digital Circuit Board Timing RatesElectrical Diagram Burnpot Replacement PartsLifetime Limited Warranty