Avalon Stoves 745, 790 Surround Panels, Insert Installation Considerations, Clearance fireplaces

Page 17

Insert Installation (for qualified installers only)

17

SAFETY NOTICE:

Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

Planning The Installation

We suggest that you have an authorized Travis Industries dealer install your stove. If you install the stove yourself, your authorized dealer should review your plans for installation.

Check with local building officials for any permits required for installation of this stove and notify your insurance company before proceeding with installation.

Preparation for Installation

Check for damage to the exterior of the inserts (dents should be reported, scratches can be fixed by applying touch up paint).

Check the interior of the firebox (replace cracked firebrick and make sure baffle is in place).

The stove can be lightened by removing the firebricks and baffle. (pg 26) - replace before operation.

Insert Installation Considerations

This insert is approved for installation into an existing masonry or zero clearance (metal) fireplace. Depending upon your installation concerns, several options are yours to provide the most desirable installation. The sections that follow detail the requirements that must be met for a safe installation.

To further help installation, the most common types of installations are explained in table below. Prior to installing your insert make a detailed plan with dimensions to double-check them against all of the requirements listed.

Installation Type

Considerations

Insert with Positive Flue (Full Reline)

• Utilizes existing masonry or zero clearance fireplace

(Page 21)

• Provides best draft

 

• Easiest to clean

Insert with Direct Connect Flue

• Utilizes existing masonry or zero clearance fireplace

(Page 21 and 22)

• Provides good draft

 

• Requires fireplace block-off plate - see page 18

Insert with Face Seal Connection

• Utilizes existing masonry fireplaces with cross section

(Page 22)

of 28" to 144" (not approved for zero

clearance fireplaces)

 

 

• Provides okay draft

 

• Easiest to install

 

• Requires the optional surround panels and insulation

 

(see "Surround Panels" on page 42).

Surround Panels

The insert must be installed with surround panels (see page 42).

Travis Industries

93508133

4 020509

Image 17
Contents Pendleton 2Introduction Mail your Warranty Card Today, and Save Your Bill of SaleT r o d u c t i o n Important Information Travis Industries 93508133 050124Table of Contents Ashes Safety PrecautionsHome Mobile6Features & Specifications Preparation for Installation Planning The InstallationStove Installation Considerations Installation Type ConsiderationsFloor Protection Requirements Clearances Stove Placement RequirementsPerformance Chimney RequirementsDrafting Outside Air Requirements Chimney Termination RequirementsSlanted Roofs FlatPendleton Minimum Clearance Alcove Installation RequirementsSee Illustration below Combustible Non-CombustibleMobile Home Requirements Minimum Clearance 5 Reduced See Illustration below ConnectorChimney Cap See the section Chimney T E T e r i o r C t o r y I l t I m n e yInterior or Exterior Masonry Chimney Surround Panels Insert Installation Considerations28 to 144 not approved for zero Clearance fireplacesInsert Size Requirements see Illustration below Insert Placement RequirementsHearth Requirements N i m u mMasonry Fireplace Requirements Leveling Bolt InstallationZero-Clearance Metal Fireplace Requirements Drafting PerformanceBlock-Off Plate Template Block-Off Plate InstallationInsert with Positive Connection Insert with Operating Your Appliance Safety NoticeBefore Your First Fire Opening the DoorStarting a Fire Ash Removal Adjusting the Burn RateApproximate Air Control Settings Re-Loading the Stove Optional Blower OperationOvernight Burn Normal Operating SoundsSelecting Wood Hints for BurningTroubleshooting Clean the Glass if necessary Daily Maintenance while stove is in useMaintaining Your Appliance Remove Ash if necessaryDoor and Glass Inspection Monthly Maintenance while appliance is in useCreosote Formation and Need for Removal Travis Industries 93508133 020604Cleaning the Air Duct and Blower if applicable Yearly MaintenanceTouch Up Paint Firebrick and Baffle InspectionReplacing the Glass Door PartsReplacing the Door Gasket Replacing the Door HandleTravis Industries 93508133 060417 Floor and Side Firebrick Removal & ReplacementFirebox Parts Baffle Removal & Replacement Air Tube Removal & ReplacementYears 1 & 2 Coverage Parts & Labor Limited 7 Year WarrantyYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyTravis Industries 93508133 070821 Listing LabelPedestal Optional EquipmentTop View Outside Air Installation for wood stoves onlyOptional Equipment Install the wire clip following the directions below Rear Blower Installation Part numberOutside Air Boot Installation Part number Surround Panels see Below Required for face seal installations onlyTravis Industries 93508133 051104 Size on Insert w trimFront Blower To Switch the Power Cord to the Left Side44Index

790, 745 specifications

Avalon Stoves has made a name for itself in the realm of high-efficiency wood stoves, and the Avalon 745 and Avalon 790 models stand out as exceptional choices for homeowners looking to heat their spaces sustainably and effectively. These units are designed with a focus on performance, aesthetics, and user-friendliness, making them ideal for both new installations and replacements.

One of the main features of the Avalon 745 is its unique design that accommodates larger logs while maintaining an efficient burn. With a firebox capacity of 3.4 cubic feet, this stove can hold logs up to 18 inches in length, allowing for longer burn times and reduced wood handling. The 790 model, on the other hand, offers an even larger capacity, making it suited for heating larger spaces or for users who prefer fewer reloads. Both models feature a top-loading design that simplifies the process of adding fuel.

In terms of technology, Avalon stoves employ a range of advanced features to optimize heating output. One key aspect is the secondary combustion system, which enhances efficiency by allowing the smoke and gases released during burning to combust again. This not only maximizes heat output but also minimizes emissions, making the stove a more environmentally friendly option. Additionally, the air wash system helps keep the glass clean, providing an unobstructed view of the fire while reducing the frequency of maintenance.

The construction quality of Avalon stoves is noteworthy. Built with heavy-duty steel and lined with firebrick, these stoves are designed for durability and heat retention. The high-efficiency design ensures that the heat generated is distributed evenly throughout the room, providing consistent warmth even during the coldest months. With an EPA certification, both the 745 and 790 models meet stringent emission standards, making them one of the cleaner-burning options available.

Aesthetic appeal is also a significant consideration in the design of Avalon stoves. Both models feature a sleek, contemporary look that can seamlessly integrate into a variety of home decors. Customers can choose from a range of finishes and door styles to match their personal preferences and existing interiors.

In conclusion, the Avalon 745 and 790 stoves highlight the brand's commitment to efficiency, quality, and style. With their advanced technologies, robust construction, and elegant designs, these stoves not only provide warmth but also enhance the ambiance of any living space. For homeowners seeking a reliable and attractive heating solution, Avalon stoves are a commendable choice.