Front Blower (part # 99000137)

TO SWITCH THE POWER CORD TO THE LEFT SIDE:

Follow the directions below to switch the power cord. Make sure the power cord, wires, or molex assembly do not protrude into the opening of the blower.

The wires tuck in here, directly behind the blower cage.

Remove the strain relief by

squeezing it from the top and bottom

with a pair of slip-joint pliers.

Disconnect the molex plug inside the blower assembly. Remove the power cord by pulling it out of the hole exposed by removing the strain relief.

Left Side of

Blower

Assembly

Remove the button plug from the

left side and insert it into the hole

on the right side.

INSTALLATION INSTRUCTIONS

1.The Rainier (945/990) and Olympic (1190), require removal of the button plug below the blower knob and installation of the air control rod extention (see illustration below).

2.Install the snap disk (see the illustration below. The round disc must be facing upwards and come in contact with the bottom of the firebox for the blower to operate correctly.

Ashlip of Appliance

Bend these legs on the snap disk if it does not fit tightly

Wedge the snap disk in back of the stiffener on the left side

The air control extender allows the air control rod to pass through the blower assembly on the Rainier (945/990) and Olympic (1190).

Button Plug for Air Control Rod

Wood Air Control Handle

(For the Rainier (945/990) and Olympic (1190)

3.Make sure the wires leading to the snap disk are routed above the left side blower outlet (to prevent damage to the wires during installation). Install the blower following the directions below.

ake sure the wires run over he top of the blower housing nd are not damaged when the lower is installed.

his clip aligns the blower nside the convection channel.

Insert the baseplate of the appliance into this gap.

This clip slips over the edge of the appliance unibody and locks the blower in place.

Baseplate of Appliance

(Below Ashlip)

Front of

Appliance

Travis Industries

93508133

4 020509

Image 43
Contents Pendleton Travis Industries 93508133 050124 Mail your Warranty Card Today, and Save Your Bill of Sale2Introduction T r o d u c t i o n Important InformationTable of Contents Ashes Safety PrecautionsHome Mobile6Features & Specifications Installation Type Considerations Planning The InstallationPreparation for Installation Stove Installation ConsiderationsFloor Protection Requirements Clearances Stove Placement RequirementsDrafting Chimney RequirementsPerformance Flat Chimney Termination RequirementsOutside Air Requirements Slanted RoofsCombustible Non-Combustible Alcove Installation RequirementsPendleton Minimum Clearance See Illustration belowMobile Home Requirements Minimum Clearance 5 Reduced See Illustration below ConnectorChimney Cap See the section Chimney T E T e r i o r C t o r y I l t I m n e yInterior or Exterior Masonry Chimney Clearance fireplaces Insert Installation ConsiderationsSurround Panels 28 to 144 not approved for zeroN i m u m Insert Placement RequirementsInsert Size Requirements see Illustration below Hearth RequirementsDrafting Performance Leveling Bolt InstallationMasonry Fireplace Requirements Zero-Clearance Metal Fireplace RequirementsBlock-Off Plate Template Block-Off Plate InstallationInsert with Positive Connection Insert with Opening the Door Safety NoticeOperating Your Appliance Before Your First FireStarting a Fire Approximate Air Control Settings Adjusting the Burn RateAsh Removal Normal Operating Sounds Optional Blower OperationRe-Loading the Stove Overnight BurnSelecting Wood Hints for BurningTroubleshooting Remove Ash if necessary Daily Maintenance while stove is in useClean the Glass if necessary Maintaining Your ApplianceTravis Industries 93508133 020604 Monthly Maintenance while appliance is in useDoor and Glass Inspection Creosote Formation and Need for RemovalFirebrick and Baffle Inspection Yearly MaintenanceCleaning the Air Duct and Blower if applicable Touch Up PaintReplacing the Door Handle Door PartsReplacing the Glass Replacing the Door GasketFirebox Parts Floor and Side Firebrick Removal & ReplacementTravis Industries 93508133 060417 Baffle Removal & Replacement Air Tube Removal & ReplacementYears 6 & 7 Coverage Parts only Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 3 Through 5 Coverage Parts & LaborTravis Industries 93508133 070821 Listing LabelPedestal Optional EquipmentTop View Outside Air Installation for wood stoves onlyOptional Equipment Install the wire clip following the directions below Rear Blower Installation Part numberOutside Air Boot Installation Part number Size on Insert w trim Required for face seal installations onlySurround Panels see Below Travis Industries 93508133 051104Front Blower To Switch the Power Cord to the Left Side44Index

790, 745 specifications

Avalon Stoves has made a name for itself in the realm of high-efficiency wood stoves, and the Avalon 745 and Avalon 790 models stand out as exceptional choices for homeowners looking to heat their spaces sustainably and effectively. These units are designed with a focus on performance, aesthetics, and user-friendliness, making them ideal for both new installations and replacements.

One of the main features of the Avalon 745 is its unique design that accommodates larger logs while maintaining an efficient burn. With a firebox capacity of 3.4 cubic feet, this stove can hold logs up to 18 inches in length, allowing for longer burn times and reduced wood handling. The 790 model, on the other hand, offers an even larger capacity, making it suited for heating larger spaces or for users who prefer fewer reloads. Both models feature a top-loading design that simplifies the process of adding fuel.

In terms of technology, Avalon stoves employ a range of advanced features to optimize heating output. One key aspect is the secondary combustion system, which enhances efficiency by allowing the smoke and gases released during burning to combust again. This not only maximizes heat output but also minimizes emissions, making the stove a more environmentally friendly option. Additionally, the air wash system helps keep the glass clean, providing an unobstructed view of the fire while reducing the frequency of maintenance.

The construction quality of Avalon stoves is noteworthy. Built with heavy-duty steel and lined with firebrick, these stoves are designed for durability and heat retention. The high-efficiency design ensures that the heat generated is distributed evenly throughout the room, providing consistent warmth even during the coldest months. With an EPA certification, both the 745 and 790 models meet stringent emission standards, making them one of the cleaner-burning options available.

Aesthetic appeal is also a significant consideration in the design of Avalon stoves. Both models feature a sleek, contemporary look that can seamlessly integrate into a variety of home decors. Customers can choose from a range of finishes and door styles to match their personal preferences and existing interiors.

In conclusion, the Avalon 745 and 790 stoves highlight the brand's commitment to efficiency, quality, and style. With their advanced technologies, robust construction, and elegant designs, these stoves not only provide warmth but also enhance the ambiance of any living space. For homeowners seeking a reliable and attractive heating solution, Avalon stoves are a commendable choice.