Optional Equipment

Surround

Panels (see

part #'s below)

 

 

 

 

 

 

 

 

 

 

 

S i z e

Size on Insert (w trim)

PART #

 

 

 

8"

39 7/8" width by 28" height

99300259

 

 

 

 

10"

43 7/8" width by 30" height

99300260

 

 

 

 

12"

47 7/8" width by 32" height

99300261

 

 

I N S T A L L A T I O N

I N S T R U C T I O N S

Avalon Pendleton-45 and Rainier-45:

1.With the insert 12” from the fireplace, install the side surround panels (see the directions to the right).

2.Adjust the position of the side panels so they are: 1) aligned with the top of the insert; 2) both the same distance back from the front of the insert; 3) perpendicular to the floor (use the top panel, if necessary, to judge alignment). Tighten the screws that hold the side panels in place.

3.Install the top panel and trim following the directions to the right.

Button Plugs

(pry out with a screwdriver)

Remove the brass trim along the top of the stove.

 

Attach the side panels with

Side

the included screws (hint:

 

Panel

pre-thread the holes prior

 

 

to installing the panels).

I n s u l a t i o n

I n s t a l l a t i o n

(required for face seal installations only)

5/16" Nutdriver

1.With the insert drawn 6" from the fireplace, glue the insulation strip included with the surround panel kit to the back of the panels using RTV silicon or stove gasket cement. The insulation should be installed so it overlaps the fireplace opening to form a seal between the panels and the fireplace face. Let the silicon or cement dry.

2.Push the insert into the fireplace, allowing the insulation to form a seal between the panels and the fireplace. Use a screwdriver to tuck any exposed insulation behind the panels.

Spring

Clips

Install the top panel so the tabs insert into the joggle clips on the top panel

5/16" Nutdriver

Top Trim

Top

Micro (1/16”)

Standard

Screwdriver

Top Trim

"L" Bracket

Right Side

Trim

Optional Trim Installation:

Insert one leg of each "L" bracket into the top and side trim piece. Align the trim to form a precise corner, then tighten the two set screws with a small standard screwdriver. Slide the trim over the panels. Place the spring clips behind the panels at the locations shown. This keeps the trim tight against the panel.

Optional Knock-OutAn optional knock-out is provided on both sides if the power cord is routed behind the surround panel.

Travis Industries

93508133

4 051104

Image 42
Contents Pendleton T r o d u c t i o n Important Information Mail your Warranty Card Today, and Save Your Bill of Sale2Introduction Travis Industries 93508133 050124Table of Contents Safety Precautions AshesMobile Home6Features & Specifications Stove Installation Considerations Planning The InstallationPreparation for Installation Installation Type ConsiderationsFloor Protection Requirements Stove Placement Requirements ClearancesChimney Requirements DraftingPerformance Slanted Roofs Chimney Termination RequirementsOutside Air Requirements FlatSee Illustration below Alcove Installation RequirementsPendleton Minimum Clearance Combustible Non-CombustibleMinimum Clearance 5 Reduced See Illustration below Connector Mobile Home RequirementsChimney Cap See the section Chimney T e r i o r C t o r y I l t I m n e y T EInterior or Exterior Masonry Chimney 28 to 144 not approved for zero Insert Installation ConsiderationsSurround Panels Clearance fireplacesHearth Requirements Insert Placement RequirementsInsert Size Requirements see Illustration below N i m u mZero-Clearance Metal Fireplace Requirements Leveling Bolt InstallationMasonry Fireplace Requirements Drafting PerformanceBlock-Off Plate Installation Block-Off Plate TemplateInsert with Positive Connection Insert with Before Your First Fire Safety NoticeOperating Your Appliance Opening the DoorStarting a Fire Adjusting the Burn Rate Approximate Air Control SettingsAsh Removal Overnight Burn Optional Blower OperationRe-Loading the Stove Normal Operating SoundsHints for Burning Selecting WoodTroubleshooting Maintaining Your Appliance Daily Maintenance while stove is in useClean the Glass if necessary Remove Ash if necessaryCreosote Formation and Need for Removal Monthly Maintenance while appliance is in useDoor and Glass Inspection Travis Industries 93508133 020604Touch Up Paint Yearly MaintenanceCleaning the Air Duct and Blower if applicable Firebrick and Baffle InspectionReplacing the Door Gasket Door PartsReplacing the Glass Replacing the Door HandleFloor and Side Firebrick Removal & Replacement Firebox PartsTravis Industries 93508133 060417 Air Tube Removal & Replacement Baffle Removal & ReplacementYears 3 Through 5 Coverage Parts & Labor Limited 7 Year WarrantyYears 1 & 2 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyListing Label Travis Industries 93508133 070821Optional Equipment PedestalOutside Air Installation for wood stoves only Top ViewOptional Equipment Rear Blower Installation Part number Install the wire clip following the directions belowOutside Air Boot Installation Part number Travis Industries 93508133 051104 Required for face seal installations onlySurround Panels see Below Size on Insert w trimTo Switch the Power Cord to the Left Side Front Blower44Index

790, 745 specifications

Avalon Stoves has made a name for itself in the realm of high-efficiency wood stoves, and the Avalon 745 and Avalon 790 models stand out as exceptional choices for homeowners looking to heat their spaces sustainably and effectively. These units are designed with a focus on performance, aesthetics, and user-friendliness, making them ideal for both new installations and replacements.

One of the main features of the Avalon 745 is its unique design that accommodates larger logs while maintaining an efficient burn. With a firebox capacity of 3.4 cubic feet, this stove can hold logs up to 18 inches in length, allowing for longer burn times and reduced wood handling. The 790 model, on the other hand, offers an even larger capacity, making it suited for heating larger spaces or for users who prefer fewer reloads. Both models feature a top-loading design that simplifies the process of adding fuel.

In terms of technology, Avalon stoves employ a range of advanced features to optimize heating output. One key aspect is the secondary combustion system, which enhances efficiency by allowing the smoke and gases released during burning to combust again. This not only maximizes heat output but also minimizes emissions, making the stove a more environmentally friendly option. Additionally, the air wash system helps keep the glass clean, providing an unobstructed view of the fire while reducing the frequency of maintenance.

The construction quality of Avalon stoves is noteworthy. Built with heavy-duty steel and lined with firebrick, these stoves are designed for durability and heat retention. The high-efficiency design ensures that the heat generated is distributed evenly throughout the room, providing consistent warmth even during the coldest months. With an EPA certification, both the 745 and 790 models meet stringent emission standards, making them one of the cleaner-burning options available.

Aesthetic appeal is also a significant consideration in the design of Avalon stoves. Both models feature a sleek, contemporary look that can seamlessly integrate into a variety of home decors. Customers can choose from a range of finishes and door styles to match their personal preferences and existing interiors.

In conclusion, the Avalon 745 and 790 stoves highlight the brand's commitment to efficiency, quality, and style. With their advanced technologies, robust construction, and elegant designs, these stoves not only provide warmth but also enhance the ambiance of any living space. For homeowners seeking a reliable and attractive heating solution, Avalon stoves are a commendable choice.