Avalon Stoves 745, 790 owner manual Stove Placement Requirements, Clearances

Page 9

Stove Installation (for qualified installers only)

9

Stove Placement Requirements

Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or other means approved by local building or fire officials.

Stove must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36" of the front of the stove

If the stove is placed in a location where the ceiling height is less than 7', it must follow the requirements in the section "Alcove Installation Requirements"

Must maintain the clearances to combustibles listed below (drywall, furniture, etc.):

Clearances

Corner Installations

Straight Installations

d

e

f

a

b

c

NOTE:

Measure clearances to the stove top.

 

 

 

Pendleton - 45°

Pendleton - 90°

Minimum

Clearance

Singlewall

Reduced

Singlewall

Reduced

(See

the

illustration above)

Connector

Clearance*

Connector

Clearance*

A

Sidewall to stove

10"

11"

10"

11"

B

Backwall to stove

19 1/2"

13"

16 1/2"

8 1/2"

C

Cornerwall to stove

9 1/2"

7 1/2"

9 1/2"

7 1/2"

D

Connector to sidewall

19"

19 1/2"

19"

19 1/2"

E

Connector to backwall

17 1/2"**

9"**

17 1/4"

8 3/4"

F

Connector to cornerwall

16"**

11"**

17 1/2"

15"

*

Reduced clearance installations require one of

the chimneys and connectors listed below:

 

• DURAVENT model DVL with DURATEC chimney

• GSW Double Wall Chimney Connector with Super Chimney Twenty-One

 

• DURAVENT model DVL with DURA-PLUS chimney

• SELKIRK METALBESTOS model DS connector with model SSII chimney

 

AMERI-TEC model DCC with model HS chimney

• I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector

 

• SECURITY model DL with SECURITY model ASHT or S2100 chimney

• Standard Masonry Chimney with any one of the above listed connectors

METAL-FAB model DW with TG chimney

**These are minimum clearances, not installation dimensions. Connector position will vary depending upon brand. First establish the stove clearances, install the 45° connector to the stove, then determine the position of the connector.

NOTE : Standard residential installations with reduced clearance connector may use the clearance determined by the manufacturer of the connector for the connector to wall clearance or the clearance listed in this manual. Offsets must be used to maintain the stove to wall clearance.

NOTE : Reduced clearance connectors may not connect to the flue collar – order an appliance adapter for the connector being used.

Travis Industries

93508133

4 020509

Image 9
Contents Pendleton 2Introduction Mail your Warranty Card Today, and Save Your Bill of SaleT r o d u c t i o n Important Information Travis Industries 93508133 050124Table of Contents Ashes Safety PrecautionsHome Mobile6Features & Specifications Preparation for Installation Planning The InstallationStove Installation Considerations Installation Type ConsiderationsFloor Protection Requirements Clearances Stove Placement RequirementsChimney Requirements DraftingPerformance Outside Air Requirements Chimney Termination RequirementsSlanted Roofs FlatPendleton Minimum Clearance Alcove Installation RequirementsSee Illustration below Combustible Non-CombustibleMobile Home Requirements Minimum Clearance 5 Reduced See Illustration below ConnectorChimney Cap See the section Chimney T E T e r i o r C t o r y I l t I m n e yInterior or Exterior Masonry Chimney Surround Panels Insert Installation Considerations28 to 144 not approved for zero Clearance fireplacesInsert Size Requirements see Illustration below Insert Placement RequirementsHearth Requirements N i m u mMasonry Fireplace Requirements Leveling Bolt InstallationZero-Clearance Metal Fireplace Requirements Drafting PerformanceBlock-Off Plate Template Block-Off Plate InstallationInsert with Positive Connection Insert with Operating Your Appliance Safety NoticeBefore Your First Fire Opening the DoorStarting a Fire Adjusting the Burn Rate Approximate Air Control SettingsAsh Removal Re-Loading the Stove Optional Blower OperationOvernight Burn Normal Operating SoundsSelecting Wood Hints for BurningTroubleshooting Clean the Glass if necessary Daily Maintenance while stove is in useMaintaining Your Appliance Remove Ash if necessaryDoor and Glass Inspection Monthly Maintenance while appliance is in useCreosote Formation and Need for Removal Travis Industries 93508133 020604Cleaning the Air Duct and Blower if applicable Yearly MaintenanceTouch Up Paint Firebrick and Baffle InspectionReplacing the Glass Door PartsReplacing the Door Gasket Replacing the Door HandleFloor and Side Firebrick Removal & Replacement Firebox PartsTravis Industries 93508133 060417 Baffle Removal & Replacement Air Tube Removal & ReplacementYears 1 & 2 Coverage Parts & Labor Limited 7 Year WarrantyYears 3 Through 5 Coverage Parts & Labor Years 6 & 7 Coverage Parts onlyTravis Industries 93508133 070821 Listing LabelPedestal Optional EquipmentTop View Outside Air Installation for wood stoves onlyOptional Equipment Install the wire clip following the directions below Rear Blower Installation Part numberOutside Air Boot Installation Part number Surround Panels see Below Required for face seal installations onlyTravis Industries 93508133 051104 Size on Insert w trimFront Blower To Switch the Power Cord to the Left Side44Index

790, 745 specifications

Avalon Stoves has made a name for itself in the realm of high-efficiency wood stoves, and the Avalon 745 and Avalon 790 models stand out as exceptional choices for homeowners looking to heat their spaces sustainably and effectively. These units are designed with a focus on performance, aesthetics, and user-friendliness, making them ideal for both new installations and replacements.

One of the main features of the Avalon 745 is its unique design that accommodates larger logs while maintaining an efficient burn. With a firebox capacity of 3.4 cubic feet, this stove can hold logs up to 18 inches in length, allowing for longer burn times and reduced wood handling. The 790 model, on the other hand, offers an even larger capacity, making it suited for heating larger spaces or for users who prefer fewer reloads. Both models feature a top-loading design that simplifies the process of adding fuel.

In terms of technology, Avalon stoves employ a range of advanced features to optimize heating output. One key aspect is the secondary combustion system, which enhances efficiency by allowing the smoke and gases released during burning to combust again. This not only maximizes heat output but also minimizes emissions, making the stove a more environmentally friendly option. Additionally, the air wash system helps keep the glass clean, providing an unobstructed view of the fire while reducing the frequency of maintenance.

The construction quality of Avalon stoves is noteworthy. Built with heavy-duty steel and lined with firebrick, these stoves are designed for durability and heat retention. The high-efficiency design ensures that the heat generated is distributed evenly throughout the room, providing consistent warmth even during the coldest months. With an EPA certification, both the 745 and 790 models meet stringent emission standards, making them one of the cleaner-burning options available.

Aesthetic appeal is also a significant consideration in the design of Avalon stoves. Both models feature a sleek, contemporary look that can seamlessly integrate into a variety of home decors. Customers can choose from a range of finishes and door styles to match their personal preferences and existing interiors.

In conclusion, the Avalon 745 and 790 stoves highlight the brand's commitment to efficiency, quality, and style. With their advanced technologies, robust construction, and elegant designs, these stoves not only provide warmth but also enhance the ambiance of any living space. For homeowners seeking a reliable and attractive heating solution, Avalon stoves are a commendable choice.