Plasmon LF 8600 user manual Connecting Power and Scsi Cables, Connecting the Power Cord

Page 48

CONNECTING POWER AND SCSI CABLES

After the LF 8600 has been installed in its operating location, refer to the next three sections for power cord installation and SCSI cable installation for a single device.

The LF 8600 has two SCSI input/output (I/O) connectors on the rear panel that are used to interface the drive with other SCSI devices (see figure below). Either SCSI connector can be used as the input or output port because the internal controller cable connection is common to both connectors.

SCSI

 

CONNECTORS

AC POWER

 

 

CABLE

AC POWER

SWITCH

Figure 27. Rear Panel of the LF 8600 Showing SCSI Connectors and AC Power Cord

CONNECTING THE POWER CORD

To install the power cord on an LF 8600:

1.Ensure that an AC power cord is available and ready for installation. The type of AC power cord being installed depends upon the installation location.

2.Ensure facility power is available and the AC power cord connector (male end) will match the site AC power wall outlet.

3.Ensure that the AC power switch on the LF 8600 rear panel is set to the OFF ( O ) position.

4.Plug the AC power cord connector (female end) into the AC power receptacle on the

LF 8600 rear panel.

5. Plug the AC power cord connector (male end) into a wall outlet.

PLASMON L M S - LF 8600 USER MANUAL Page 48

Image 48
Contents Plasmon 8000 Series Page Page Page Agency Compliance and Approval Page Table of Contents Appendix a Scope Related PublicationsPage General Description Page Drive Characteristics Front Panel Rear PanelDimensions and Weight Shipping WeightTEMPERATURE, Humidity and Altitude TransitMedia Environmental Characteristics Shock and VibrationAC Power Requirements AC Power CordPower Supply OUT-OF-RANGE Protection Features AC GroundTilt Range Heat DissipationParticulate Limits Page Unpacking the Tower Configuration Unpacking and Repacking InstructionsLF 8600 Tower Packing Caster for the LF 8600 Tower Unpacking the Rack Mount Configuration LF 8600 Rack Mount Packing Inspecting the LF Repacking the LFClosing the Baseplates Manually Closing the Drives BaseplatesRepacking the Tower Configuration Repacking the Rack Mount Configuration Moving the Shuttle Assembly to the Shipping PositionPage Installation DE-INSTALLATION Installation RequirementsTower Installation Rack Mount Installation LF 8600 Rack Mount KitLF 8600 Side-by-Side Rack Mount Page Mounting the Platform Support Rack Mounting the Slide Assembly to the Platform Support Rack Extending the Slide Platform Assembly Securing the Platform to the Slide Assembly Do Not Extend Both Drives Simultaneously Mounting the LF 8600 Chassis to the Extended Platform LF 8600 Rack Mount Slide Detail Standard Rack Mounted LF 8600 in the Retention Lock Position Installing the Lateral Support Angle Installing the Cabinet Trim Panel Scsi BUS Considerations Host-to-LF 8600 Daisy Chain Cable ConnectionsLF 8600-to-Host Cable Connection Connecting Power and Scsi Cables Connecting the Power CordConnecting Multiple Devices Multiple LF 8600 Scsi Interface Cable ConnectionsConnecting a Single Device Connector Verification Rack Mount Configuration DE-INSTALLATIONLF 8600 Slide Release Location Vertical Tail Page Controls and Indicators Operating InstructionsPOWER-ON Procedure LF 8600 AC Power Switch PositionsOperating Mode Modes of OperationLF 8600 DOC Operating Mode Messages Configuration Mode Viewing the configuration View ConfigPage Main Menu Viewing the Configuration View Config View Configuration MessagesView Config Menu Set Configuration menu Set Config Menu Part CDE Curs SET Defaults Setting the Scsi IDSetting the BUS Parity Checking Setting the LanguageSetting the Write Protect Option Setting the Media Autoload OptionSetting the Load Switch Option Setting the Read Ahead OptionSetting the CDE Curs Option Setting the Busy Option Setting the Modsel RA OptionSetting the MM Spinup Option Select Target NegotiationClear NvRAM Diagnostics Selftests Clear Rtpm Diagnostics Menu Part Diagnostic Menu Part SET the Internal Drive Serial Number SET Serial # Set Serial # Menu Test Mode To perform any of the diagnostic testMedia Cartridge Handling Side a ViewPage Setting the Write Protection Switch Manually Write Protecting the Media CartridgeAffixing Labels Media Insertion and RemovalLF 8600 Media Access Cartridge Insertion Data Cartridge InsertionCartridge Removal LM 8000 Cartridge RemovalManual Cartridge Release Mechanism Opening the BaseplatesRemoving the Bezel Manually Overriding the Door LockBezel Removal Retracting the Cartridge LF 8600 Manual Cartridge RetractionMedia Loading Page Operator Maintenance Inspecting and Cleaning FAN and Blower FiltersReplacing Fuses Removing Filter ElementRemoving Fuse from AC Power Receptacle Rear View of LF Media Cleaning Media Cleaning Using Cleaning KIT P/NGerman TRANSLATIONS/ÜBERSETZUNGEN INS Deutsche Abmessungen UND GewichtTEMPERATUR, Luftfeuchtigkeit UND Seehöhe Bedingung Betrieb Ruhe Lagerung Transport Stoss UND Vibration WechselstrombedarfWechselstromerdung KipptoleranzWärmeausstrahlung Grenzwerte FÜR DIE StaubkonzentrationAuspachen DES LF6600 Wiederverpacken DES LFWarnung Einsetzung Erforderis Turmmontage ANSCHLUß DES Netzkabels Anschlussüberprüfung Abbau DER GestellmontagenkonfigurationEinstellen DIE Device ID Hinweis Handhabung VON Datenträgerkassetten Auswechseln VON Sicherungen Warnung Vorsicht Storing More Of Your Digital World . Permanently

LF 8600 specifications

The Plasmon LF 8600 is an advanced optical disc archival system designed for long-term data storage and retrieval. It is part of a broader range of Plasmon products aimed at meeting the growing demand for secure and reliable data preservation in various industries, including healthcare, finance, and government. This system is particularly renowned for its efficiency, scalability, and innovative technology.

One of the main features of the Plasmon LF 8600 is its ability to handle large volumes of data. With a capacity of up to 30 terabytes in a single library, the LF 8600 is capable of storing an extensive amount of information, making it ideal for organizations that require long-term data retention. The high storage density ensures that users can archive vast amounts of data without taking up significant physical space.

The LF 8600 utilizes a high-speed optical technology, allowing for rapid data access and retrieval. It employs a unique dual-stage optical read/write mechanism that enhances performance, offering fast transfer rates of up to 1.6 GB/minute. This level of efficiency minimizes downtime and allows users to access their critical data quickly, which is essential for operation in fast-paced environments.

In terms of reliability, the Plasmon LF 8600 is built for durability. The system uses high-quality optical discs that provide exceptional resistance to data degradation and environmental factors. These discs are designed to last for decades, ensuring that the stored data remains intact and accessible throughout their lifespan.

The LF 8600 also features a robust software management interface, enabling users to seamlessly manage their archived data. This software supports automated data migration and archival processes, reducing the risk of human error. Additionally, the interface allows for straightforward indexing and searching of stored files, simplifying data retrieval when required.

Security is a top priority for the LF 8600 system. It includes various features such as user authentication, data encryption, and compliance with industry standards, ensuring that sensitive information remains protected against unauthorized access.

Overall, the Plasmon LF 8600 represents a significant advancement in optical archiving technology. With its high capacity, fast data access, reliability, and strong security features, the LF 8600 is an excellent choice for organizations looking to invest in a long-term data storage solution that can efficiently meet their evolving needs.