Frigidaire DH400MY5, LD65ELY5, DH300EY5, LD40EY5, DH400EY5, LD40Y5 Control Parts, Power Cord Assembly

Page 14

3.2 CONTROL PARTS

3.2.1 POWER CORD ASSEMBLY

1.After opening the control box, remove the screw that holds the ground wire. (See Figure 15)

2.Disconnect the remaining leads of the power cord from the PWB(PCB) ASSEMBLY, MAIN, then remove it from the control box.

3.2.2 SENSOR ASSEMBLY

1.Disconnect the sensor assembly from the

PWB(PCB) ASSEMBLY, MAIN.

2.Remove the screw which fastens the humidity sensor. (See Figure 16)

3.Remove the thermistor from the holder. (See Figure 16)

4.Disconnect the switch wires from the micro switch assembly. (See Figure 16)

3.2.3 PWB(PCB) ASSEMBLY, MAIN

1.Disconnect all leads of the motor and the compressor from PWB(PCB) ASSEMBLY, MAIN.

2.Remove the screw which fastens the PWB(PCB) ASSEMBLY, MAIN and pull it out after unhooking from 2 rectangular holes of the control box (lower). (See Figure 17)

3.2.4 CAPACITOR

1.Remove the screw that fastens the capacitor. (See Figure 17)

2.Disconnect all leads from the capacitor and then remove it from control box.

3.2.5 MICRO SWITCH ASSEMBLY

1.Turn the nut counterclockwise and pull out the micro switch from the drain pan. (See Figure 18)

—14—

Figure 15

Figure 16

Figure 17

Figure 18

Image 14
Contents Dehumidifier Contents Features Safety PrecautionsFeatures and Dimensions Specifications Model NamesControl Type Mechanical typeHOW does the Dehumidifier WORK? HOW to Operate DehumidifierMicro Switch Location for the DehumidifierMechanical Type Electronic TypeDH305Y5,DH300MY5 Model DH305Y5, DH300MY5Description Model DH300EY5 DH300EY5Model DH400MY5/LD40Y5 DH400MY5/LD40Y5LD40EY5 Model DH404EY5/DH400EY5/LD40EY5DH404EY5/DH400EY5 Model DH504ELY5/LD50ELY5/LD65ELY5 DH504ELY5/LD50ELY5 LD65ELY5Front Case and Rear Grille Mechanical PartsBucket and AIR Filter Cabinet and Control BOXPower Cord Assembly Control PartsCoil ASSEMBLY, Solenoid DH504ELY5, LD50ELY5, LD65ELY5 Control PanelFAN and Motor Shroud and Drain PANRefrigerating Cycle CONDENSER, Evaporator and Capillary TubeHOW to Replace the Refrigeration System Pulling Vacuum Troubleshooting Guide Condition Cause Remedy Water dripsExploded Views Model DH305Y5/DH300MY5Model DH300EY5 346811 249950 435300 264110 131400 135312 165010 238310 Model DH404EY5/DH400EY5/LD40EY5 Model DH504ELY5/LD50ELY5 Model LD65ELY5 Remark DH305Y5/DH300MY5Drier Assembly BLG/EGoldstar Model DH404E Y5/DH400EY5/LD40EY5 DH404EY5/DH400EY5/LD40EY5Model DH504ELY5/LD50ELY5 Description DH504ELY5/LD50ELY5Model LD65ELY5 Description LD65ELY5January