1.5 CONTROL TYPE

1.5.1 Mechanical type

 

4

5

 

 

6

 

 

3

7

High

 

 

 

 

2

 

8

Auto

1

9

Low

Shut-Off

 

 

 

 

 

Off

Max

Fan Speed

Humidity Control

When you first use the dehumidifier, turn the humidity control to 5 or 6. If you still have moisture, turn the humidity control to a higher setting.

MAX is the highest setting.

When excess moisture and dampness odors are gone, adjust the control to a lower setting. Use the dehumidifier as long as excess moisture is present.

Humidity Control

Auto Shut-Off

Figure 2

Fan Speed

• The fan control adjusts the fan speed.

This light glows when the bucket is full, or when the bucket is removed or not placed in the proper position. In these cases the Water Level Control Switch shuts off the dehumidifier.

When the light glows, check the bucket condition.

Set the fan control to HIGH for maximum moisture

removal. When the humidity has been reduced and

quiet operation is preferred, set the fan control to

LOW.

1.5.2 Electronic type

Constantly On.

 

HUMIDITY

 

 

 

BUCKET

4hr. On/Off

High

CONTROL

FULL

 

 

 

2hr. On/Off

Low

AUTO RESTART

TIMER

FAN

HUMIDITY

POWER

SPEED

 

 

SETTING

Figure 3

Fan Speed

This controls the speed of the airflow.

High: Fan speed is set to high.

Low: Fan speed is set to low.

When Fan Speed button is pressed, the fan speed mode is changed.

Timer

Press this button to select type of operation.

Select continuous On for uninterrupted operation.

Select either 2 or 4 hr. On/Off for cycled operation: The unit will operate for 2 or 4 hours, and then shut off completely for 2 or 4 hours.

The cycle repeats until you change the setting.

When Timer button is pressed, the Timer indicator lights shift as follow from 2hr.On/Off to 4hr.On/Off.

Bucket Full Indicator

This light glows when the water bucket is full and needs to be emptied.

Power

Operation starts when this button is pressed and stops when the button is pressed again.

Auto Restart

Once power is restored after a power outage, the unit returns to its previous operation setting after a 2 minute delay.

The fan runs immediately when the power is restored.

Humidity Control

• This button controls the humidity in the room.

• Press

button to raise the humidity setting.

• Press

button to lower the humidity setting.

The humidity setting can be set to a permanent "On" setting or to a specific humidity setting between 35% and 70% in 5% increments.

"On" setting: Dehumidifier runs continuously regardless of humidity condition.

35% - 70% setting: Dehumidifier runs on and off according to surrounding humidity conditions.

— 5—

Image 5
Contents Dehumidifier Contents Features Safety PrecautionsFeatures and Dimensions Model Names SpecificationsMechanical type Control TypeMicro Switch HOW to Operate DehumidifierHOW does the Dehumidifier WORK? Location for the DehumidifierElectronic Type Mechanical TypeDH305Y5,DH300MY5 Model DH305Y5, DH300MY5Description DH300EY5 Model DH300EY5DH400MY5/LD40Y5 Model DH400MY5/LD40Y5LD40EY5 Model DH404EY5/DH400EY5/LD40EY5DH404EY5/DH400EY5 DH504ELY5/LD50ELY5 LD65ELY5 Model DH504ELY5/LD50ELY5/LD65ELY5Bucket and AIR Filter Mechanical PartsFront Case and Rear Grille Cabinet and Control BOXControl Parts Power Cord AssemblyControl Panel Coil ASSEMBLY, Solenoid DH504ELY5, LD50ELY5, LD65ELY5Shroud and Drain PAN FAN and MotorCONDENSER, Evaporator and Capillary Tube Refrigerating CycleHOW to Replace the Refrigeration System Pulling Vacuum Troubleshooting Guide Water drips Condition Cause RemedyModel DH305Y5/DH300MY5 Exploded ViewsModel DH300EY5 346811 249950 435300 264110 131400 135312 165010 238310 Model DH404EY5/DH400EY5/LD40EY5 Model DH504ELY5/LD50ELY5 Model LD65ELY5 DH305Y5/DH300MY5 RemarkDrier Assembly BLG/EGoldstar DH404EY5/DH400EY5/LD40EY5 Model DH404E Y5/DH400EY5/LD40EY5Description DH504ELY5/LD50ELY5 Model DH504ELY5/LD50ELY5Description LD65ELY5 Model LD65ELY5January