3Com DIA3CV1100-02 manual Inner wire pair carries both voice and digital date

Page 11

Preparing the Site for the VCN Access Concentrator 11

CAUTION: Installation should be performed only by a qualified technician

The VCN AP punch-down block, which carries both data and voice, can be connected to an optional patch panel, which connects the circuits between the VCN AC and punch-down blocks.

If there is no patch panel, the VCN AC unit connects directly to the VCN

AC punch-down block and VCN AP punch-down blocks.

The VCN AC unit should be installed at the PBX punch-down block location, usually in the basement or wiring closet of a building.

The unit is installed in a 19-inch rack along with the Ethernet switch and an optional patch panel.

There are two methods for installing the Visitor and Community Network system:

With a patch panel.

Without a patch panel.

Installing the VCN To install the VCN AP punch-downblock when there is a patch panel, Access Point perform the following steps:

Punch-down Block with a Patch Panel

1Select the wire pairs according to their position in the RJ-11 telephone connector in the rear of the VCN AP. The two outside wires comprise the outer wire pair and the two inside wires comprise the inner wire pair, as shown in Figure 4 and Figure 5.

Where there is only one telephone line in a room, the two wires are connected to the inner wire pair of the phone connector shown in Figure 4 and Figure 5. The outer wire pair of the phone connector is not used.

The inner wire pair carries both voice and digital date.

Image 11
Contents Visitor and Community Network Access Concentrator 3Com Corporation 5400 Bayfront Plaza Santa Clara, California Contents Page Download Software or Find Documentation VCN Access VCN Access Concentrator Front Panel Describes the front panel VCN AC indicators and connectors Précautions de Preparing the Site Inner wire pair carries both voice and digital date Outer wire pair carries only voice Punch-Down Block Without a Patch Panel VCN Access Point Rear Panel Repeat through for up to 24 telephone lines Mounting the VCN Access Concentrator 19-inch Rack Installing the VCN Access ConcentratorFitting a Bracket for Rack Mounting Back Panel Connections VCN AC Front Panel ConnectionsIs P Pin Assignment for the RJ-21 Connector Line Cards in the VCN Access ConcentratorFemale RJ-21 Connector VCN Access Concentrator Unit Installed Without a Patch Panel Inserting MAC Addresses for VCN Access Concentrator Ports Sequence of ConfigurationManual Procedures for SuperStack II 1100/3300 VCN AC Port and VCN AP MAC Addresses VCN AC Automated Procedures for SuperStack II 1100/3300 ConfApp screen appears Figure Entering the Switch Address Community Parameter Removing Wrong Address Proper Selection Power CordFor units installed in the USA and Canada Select a flexible Page Troubleshooting LEDs to Solve ProblemsVCN AC Port LED Indications following Post Page Product Specification Product Specification Index VCN AP Glossary Vac MbaudMbps MiniDINGlossary Glossary 3COM Corporation Limited Warranty Governing LAW EMC Statements