Broan MP100, MP200, MP140 warranty Ventilator, SINGLE-STORY Home, TWO-STORY Home, Exhaust Diffusers

Page 2

PLAN THE INSTALLATION

 

LOCATION OF DIFFUSERS & INLETS

 

 

 

FRESH AIR

STALE

 

 

INLET

AIR

 

VENTILATOR

 

 

 

DIFFUSE

R

FRESH

AIR

AIR FLOW IN TYPICAL INSTALLATION

VENTILATOR

The ventilator exhausts stale air. There are normally suffi- cient natural intake openings into a dwelling to admit fresh outside air to be drawn in to replace the stale air. For better control, fresh air inlets may be used.

The ventilator should be centrally located to keep ductwork as short as possible. Locations for the ventilator include: joists in an attic space or the basement, or a wall away from the living areas.

SINGLE-STORY HOME

FRESH AIR INLETS

DUCTED

KITCHEN

RANGE HOOD

DIFFUSERDIFFUSER

DUCTED

BATH FAN

FRESH AIR INLETS

TWO-STORY HOME

FRESH AIR INLETS

EXHAUST

DIFFUSERS

(Available separately)

Exhaust diffusers regulate the flow of fresh air drawn through the house.

Exhaust diffusers should be mounted in the ceil- ings or high on the wall.

For best performance, ex- haust diffusers should be mounted in a central loca- tion. An exhaust diffuser should not be installed near a cooking area. (see figure)

COOKING AREA

Do not install

above or inside

this area

45o

45o

Cooking

Floor

Equipment

DIFFUSER

DIFFUSER SECOND

FLOOR

DUCTED

BATH FAN

FRESH AIR INLETS

DUCTED KITCHEN

RANGE HOOD

FRESH AIR INLETS (Available separately)

For best control of fresh air in a room, install a fresh air inlet.

The number of inlet vents depends on the floor plan. Consider the rooms/areas through which fresh air should flow toward the exhaust diffuser(s).

Vents should be located in outside walls, preferably near the ceiling and approximately the same distance from a diffuser. Vents should be separated from diffusers far enough to allow fresh air to mix with room air before being exhausted.

DIFFUSERDIFFUSER

DUCTED

FIRST FLOOR

 

BATH FAN

FRESH AIR INLETS

Image 2
Contents Model Plan the InstallationRecommended Ventilator Sizing SINGLE-STORY Home AIR Flow in Typical InstallationVentilator TWO-STORY HomeMount the Ventilator Install Fresh AIR InletsWire the Ventilator Connect DuctworkUSE and Care Install Exhaust DiffusersService Parts Models MP100, MP140 & MP200Avertissement Projetez LinstallationVentilator Recommandè AvertissmentVentilateur Projetez L InstallationEmplacements DES Diffuseurs & Entrées Maison À UN ÉtageRaccorder LES Conduits DE Ventilation Installez DES Prises Dair FraisMontez LE Ventilateur Posez LES Fils DU VentilatorModéles MP100, MP140 & MP200 Utilisation ET SoinPièces DE Rechange