Bryant FF1DNA, FF1DNE manual Estimated Sound Power Level dBA

Page 7

AIR DELIVERY (CFM) AT INDICATED EXTERNAL

STATIC PRESSURE AND VOLTAGE

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE—IN. WC

 

 

 

 

 

UNIT

BLOWER MOTOR

 

0.1

0.2

 

 

0.3

 

0.4

 

0.5

SIZE

SPEED

208V

 

230V

208V

 

230V

208V

 

230V

208V

 

230V

208V

 

230V

018

High

610

 

720

580

 

665

540

 

610

475

 

540

380

 

415

Low

480

 

580

450

 

545

415

 

500

375

 

430

320

 

340

 

 

 

 

 

 

024

High

895

 

985

860

 

955

825

 

915

785

 

865

730

 

805

Low

650

 

740

620

 

710

585

 

680

550

 

640

510

 

600

 

 

 

 

 

 

030

High

1160

 

1190

1105

 

1135

1050

 

1080

990

 

1020

935

 

960

Low

885

 

1025

870

 

985

835

 

940

810

 

890

770

 

840

 

 

 

 

 

 

NOTE: Data reflects a dry coil, filter, and 11-kw electric heater installed.

AIR DELIVERY PERFORMANCE CORRECTION

COMPONENT PRESSURE DROP (IN. WC) AT INDICATED AIRFLOW

 

AIR DELIVERY (CFM)

400

500

600

700

800

900

1000

1100

 

1-Element

0.007

0.010

0.015

0.025

0.035

0.055

0.070

0.080

Electric

5 kw

 

 

 

 

 

 

 

 

Heaters

2-Element

0.010

0.012

0.018

0.028

0.050

0.075

0.100

0.130

 

7.5 & 11 kw

 

 

 

 

 

 

 

 

 

Dry-to-

018

0.019

0.029

0.036

0.043

Wet

024

0.030

0.039

0.051

0.062

0.076

Coil

030

0.058

0.070

0.082

0.091

Subtract the above pressure drop corrections from unit airflow data when that component or condition is used. The remaining external static pressure will be available for the duct system.

ESTIMATED SOUND POWER LEVEL (dBA)

 

CONDITIONS

 

 

OCTAVE BAND CENTER FREQUENCY*

 

 

UNIT

 

Ext Static

 

 

 

 

 

 

 

SIZE

CFM

Pressure

63

125

250

500

1000

2000

4000

FF1-018

600

0.25

64.7

60.7

56.7

53.7

51.7

49.7

45.7

FF1-024

800

0.25

66.0

62.0

58.0

55.0

53.0

51.0

47.0

FF1-030

1000

0.25

67.0

63.0

59.0

56.0

54.0

52.0

48.0

*Estimated sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications Handbook, Chapter 52, p. 52.7.

OTHER ACCESSORIES

KIT NUMBER

DESCRIPTION

USED ON SIZES

 

 

 

KFDCC0101DCC

Cooling Control Package

All

 

 

 

KFBLG0106LGL*

Louvered Wall Panel with Frame

All

 

 

 

* 6 pack

—7—

Image 7
Contents FF1D FeaturesSizes 018, 024 Form No. PDS FF1D.18.2018 024 030 Model Number NomenclaturePhysical Data Model FF1DNA/FF1DNESide View Front View Dimensions FF1DNA, FF1DNETOP View Unit Connection SizesUnits Without Electric Heaters or Controls Unit Size Specifications024005 024075 024011 030005 030075 030011 SpecificationsSHC Correction Factor Cooling Capacities MBtuhEstimated Sound Power Level dBA Unit Familiarization Packaged Service Training Classroom Service TrainingCall for Free Catalog