SPECIFICATIONS Continued

UNITS WITH FACTORY-INSTALLED ELECTRIC HEATERS OR CONTROLS

 

UNIT SIZE

 

024005

024075

024011

 

030005

030075

030011

 

 

RATINGS & PERFORMANCES

 

 

 

 

 

 

 

 

 

 

Nominal Capacity (Btuh)*

 

24,000

24,000

24,000

 

30,000

30,000

30,000

 

 

Nominal Airflow (CFM)

 

 

870

 

 

 

1080

 

 

 

Electric Heating Output (kw @240v)

 

5.0

7.5

11.0

 

5.0

7.5

11.0

 

 

Electric Heating Capacity (MBH @208/230v)

14.0/16.9

20.4/24.7

29.4/35.7

 

14.3/17.2

20.7/25.0

29.7/36.0

 

 

ELECTRICAL

 

 

 

 

 

 

 

 

 

 

Unit Volts-Phase (60 Hz)

 

208/230—1

208/230—1

208/230—1

 

208/230—1

208/230—1

208/230—1

 

 

Operating Voltage Range

 

187—253

187—253

187—253

 

187—253

187—253

187—253

 

 

Internal Circuit Protection

 

 

 

 

None

 

 

 

 

Full Load Amps

 

18.1/20.0

27.1/30.0

39.8/44.0

 

18.1/20.0

27.1/30.0

39.8/44.0

 

 

Minimum Ampacity for Wire Sizing

 

24.5/26.9

35.8/39.4

51.6/56.9

 

25.2/27.5

36.4/40.0

52.3/57.5

 

 

Minimum Wire Size†

 

10/10

8/8

6/6

 

10/10

8/8

6/6

 

 

Maximum Wire Length (Ft)†

 

112/112

117/117

122/122

 

112/112

117/117

125/125

 

 

Maximum Fuse Size (Amps or Ckt Bkr)

 

25/30

40/40

60/60

 

30/30

40/40

60/60

 

 

Control Transformer 24V (Va)

 

 

 

 

40

 

 

 

 

INDOOR COIL

 

 

 

 

 

 

 

 

 

 

Rows & Fins Per In.

 

 

 

3 & 14

 

 

 

 

Height x Width (In.)

 

 

18 x 17.8

 

 

 

22 x 17.8

 

 

 

Face Area (Sq Ft)

 

 

2.23

 

 

 

2.73

 

 

 

R-22 Refrigerant Metering Device-FF1DNA

 

 

Check-Flo-Rater

 

 

 

 

R-22 Refrigerant Metering Device-FF1DNE

 

 

 

TXV

 

 

 

 

Piston Number‡

 

 

63

 

 

 

70

 

 

 

Condensate Drain Connection (Pri-Sec)

 

 

 

3/4 FPT

 

 

 

 

INDOOR BLOWER & MOTOR

 

 

 

 

 

 

 

 

 

 

Wheel Diameter x Width (In.)

 

 

 

10 x 6

 

 

 

 

Filter Size—Cleanable (In.)

 

 

 

16 x 20 x 1

 

 

 

 

Blower Motor HP

 

 

1/5

 

 

 

1/3

 

 

 

Blower Motor Speeds & Type

 

 

 

2 (PSC)

 

 

 

 

Full Load Amps

 

 

1.5

 

 

 

2.0

 

 

 

OPTIONAL EQUIPMENT (P/N’s)

 

 

 

 

 

 

 

 

 

 

Louvered Wall Panel with Frame

(6 Pack)

 

 

KFBLG0106LGL

 

 

 

 

Electric Heat Package

 

 

See ‘‘Optional Field-Installed Electric Heat Packages’’ Table

 

 

* Rated in accordance with U.S. Government DOE test procedures and/or ARI Standard 210/240-94.

Use copper wire only. Use 75°C in this application. When using non-metallic (NM) sheathed cable, wire size required should be based on that of 60°C con-

ductors, instead of wire sizes shown in table above per NEC 1996 Article 336-30. Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.

Check outdoor unit for required piston size.

††018 Size with 11-kw heater not approved for use with heat pumps.

—5—

Image 5
Contents Sizes 018, 024 FeaturesForm No. PDS FF1D.18.2 FF1DPhysical Data Model Number NomenclatureModel FF1DNA/FF1DNE 018 024 030TOP View Dimensions FF1DNA, FF1DNEUnit Connection Sizes Side View Front ViewUnits Without Electric Heaters or Controls Unit Size Specifications024005 024075 024011 030005 030075 030011 SpecificationsSHC Correction Factor Cooling Capacities MBtuhEstimated Sound Power Level dBA Call for Free Catalog Packaged Service Training Classroom Service TrainingUnit Familiarization