Bryant FF1DNA, FF1DNE manual Sizes 018, 024, Form No. PDS FF1D.18.2, Features

Page 1

 

FF1DNA,

FAN COIL UNITS

FF1DNE

 

Sizes 018, 024, 030

 

FEATURES

 

The FF1DNA and FF1DNE Fan Coil units are designed as

 

 

upflow indoor air handlers for split-system heat pumps and air

 

conditioners. They are available with factory- or field-installed

 

electric heaters both of which include the disconnect. A field-

 

installed cooling control with disconnect is also available. A TDR

 

(Time Delay Relay) is included with either the electric heat or

 

the cooling control packages. The FF1DNE models are avail-

 

able with a factory installed TXV.

 

This fan coil may be installed free standing, wall hung or flush

 

mounted in the wall. The 22-in. wide cabinet size in all models

 

allows units to fit between standard stud spacings. No return air

 

ductwork is required if the application provides for return air in

 

the front of the cabinet through either a louvered closet door or

 

an optional accessory decorative grille panel.

 

The cabinet exterior is made of pre-painted galvanized sheet

 

metal. The cabinet is fully insulated to meet applications in con-

 

ditioned space. Additional insulation is required if the unit is

 

installed in an unconditioned space. Unit is supplied with

 

replaceable filter.

 

Multispeed direct-drive PSC blower motors have been selected

 

to provide the proper air handling for both heating and cooling.

 

Motors are suspended at 3 points on rubber grommets for qui-

 

eter operation.

 

All refrigerant lines, electrical power, and thermostat wiring

 

enter from the top of the cabinet. Sweat-type refrigerant con-

 

nections on both liquid and suction lines make for swift, low-cost

 

installation. All service access to the unit is conveniently located

 

in the front.

 

The CHECK-FLO-RATER®piston ensures efficient and

 

dependable refrigerant metering, and eliminates potential ser-

 

 

vice requirements of other metering devices. The CHECK-FLO-

FF1D

RATER® is located inside the unit, easily accessible for piston

 

maintenance or changeout.

 

In addition, units can be factory ordered with a hard shut-off

 

thermostatic expansion valve (TXV) metering device for perfor-

 

mance improvement.

 

The drain pan is constructed of high-impact, sound-deadening,

 

corrosion-proof polyester resin. Primary and secondary drain

 

connections exit from the bottom or either side of the cabinet.

Form No. PDS FF1D.18.2

Image 1
Contents Sizes 018, 024 FeaturesForm No. PDS FF1D.18.2 FF1DPhysical Data Model Number NomenclatureModel FF1DNA/FF1DNE 018 024 030TOP View Dimensions FF1DNA, FF1DNEUnit Connection Sizes Side View Front ViewUnits Without Electric Heaters or Controls Unit Size Specifications024005 024075 024011 030005 030075 030011 SpecificationsSHC Correction Factor Cooling Capacities MBtuhEstimated Sound Power Level dBA Unit Familiarization Packaged Service Training Classroom Service TrainingCall for Free Catalog