Bryant 558J manual Application Data

Page 18

APPLICATION DATA

558J

Min operating ambient temp (cooling):

In mechanical cooling mode, your Bryant rooftop can safely operate down to an outdoor ambient temperature of 25_F (-4_C), with an accessory winter start kit. It is possible to provide cooling at lower outdoor ambient temperatures by using less outside air, economizers, and/or accessory low ambient kits.

Max operating ambient temp (cooling):

The maximum operating ambient temperature for cooling mode is 115_F (46_C). While cooling operation above 115_F (46_C) may be possible, it could cause either a reduction in performance, reliability, or a protective action by the unit’s internal safety devices.

Min and max airflow (cooling mode):

To maintain safe and reliable operation of your rooftop, operate within the cooling airflow limits. Operating above the max may cause blow-off, undesired airflow noise, or airflow related problems with the rooftop unit. Operating below the min may cause problems with coil freeze-up.

Airflow:

All units are draw-though in cooling mode.

Outdoor air application strategies:

Economizers reduce operating expenses and compressor run time by providing a free source of cooling and a means of ventilation to match application changing needs. In fact, they should be considered for most applications. Also, consider the various economizer control methods and their benefits, as well as sensors required to accomplish your application goals. Please contact your local Bryant representative for assistance.

Motor limits, break horsepower (BHP):

Due to Bryant’s internal unit design, air path, and specially designed motors, the full horsepower (maximum continuous BHP) band, as listed in Table 5, can be used with the utmost confidence. There is no need for extra safety factors, as Bryant’s motors are designed and rigorously tested to use the entire, listed BHP range without either nuisance tripping or premature motor failure.

Sizing a rooftop

Bigger isn’t necessarily better. While an air conditioner needs to have enough capacity to meet the load, it doesn’t need excess capacity. In fact, having excess capacity is often bad.

Using higher design temperatures than ASHRAE recommends for your location, adding “safety factors” to the calculated load, and rounding up to the next largest unit, are all signs of oversizing air conditioners. Oversizing can cause short-cycling, and short cycling leads to poor humidity control, reduced efficiency, higher utility bills, drastic indoor temperature swings, excessive noise, and increased wear and tear on the air conditioner.

Rather than oversizing an air conditioner, wise contractors and engineers “right-size” or even slightly undersize air conditioners. Correctly sizing an air conditioner controls humidity better; promotes efficiency; reduces utility bills; extends equipment life, and maintains even, comfortable temperatures.

Low ambient applications

When equipped with a Bryant economizer, your rooftop unit can cool your space by bringing in fresh, cool outside air. In fact, when so equipped, accessory low-ambient kit may not be necessary. In low ambient conditions, unless the outdoor air is excessively humid or contaminated, economizer-based “free cooling” is the preferred less costly and energy conscious method.

In low ambient applications where outside air might not be desired (such as contaminated or excessively humid outdoor environments), your Bryant rooftop can operate to ambient temperatures down to -40_F (-40_C) using the recommended accessory Motormaster low ambient controller.

Winter start

Bryant’s winter start kit extends the low ambient limit of your rooftop to 25_F (-4_C). The kit bypasses the low pressure switch, preventing nuisance tripping of the low pressure switch. Other low ambient precautions may still be prudent.

18

Image 18
Contents Product Data Table of Contents Features and Benefits Design Revision Cooling Tons Factory Installed OptionsUnit Type VoltageDampers FACTORY-INSTALLED Options and FIELD-INSTALLED AccessoriesEconomizers Economizer SensorsFactory Options AND/OR Accessories Alternate Motors and Drives Thru-the-Base ConnectionsElectric Heaters ARI Cooling Rating Tables Minimum Maximum Airflows Electric Heat Unit Cooling Electric HeatersMinimum Sound Performance Table Outdoor Sound dB125 250 500 1000 2000 4000 8000 Physical Data Cooling TonsElectric Heat Electrical Data Tons CRSINGLE***A00 Part Number Power 102A00 6.0 104B00 10.5 9.6 105A00 16.0 12.0/14.7 038 Curbs & Weights Dimensions Chassis Base Unit Dimensions ChassisCurb Installation Detail Typical Application Data Selection Procedure with 558J*07 Example Determine cooling and heating loadsAmbient Temperature 558J*04 105 115 EAT dB558J*05 105 115 EAT dB 558J*06 105 115 EAT dB Tons 558J*07 105 115 EAT dBStatic Pressure Adders Factory Options and/or Accessories General fan performance notesFAN Performance 558J*04CFM RPM BHP FAN Performance 558J*05 1485 1494Medium Static Option High Static Option 1512558J*06 724765 2250 980 1066 1146 1220 1291 2375 1024 558J*07 907Pulley Adjustment Unit MOTOR/DRIVE Motor Pulley Turns Open ComboECONOMIZER, Barometric Relief and PE Performance CfmElectrical Information FLA IFM MCA No P.E FLA LRA MCA/MOCP Determination no C.O. or Unpwrd C.OElectric Heater Type FLA Mocp DISC. Size558J*05 MCA/MOCP Determination W/ Pwrd C.O IFM No P.E FLA LRAType FLA MCA Mocp DISC. Size 15.5 16.5 11.5 IFM No P.E Type FLA MCA Mocp DISC. Size LRAIFM MCA No P.E LRA PH---HZ Electric Heater Unit IFM No P.E40.0 41.3 12.9 13.9 14.4 15.6 Typical Power Diagram Typical Wiring Diagram Economizer NotesElectro-mechanical units with no economizer Sequence of OperationGeneral Electro-mechanical units with an economizerGuide Specifications 558J*04-07 Hvac Guide Specifications23 09 93.13 Insert Sequence of Operation 558J 558J 558J 558J 558J 558J Catalog No. PDS558J---01

558J specifications

The Bryant 558J is a high-efficiency air conditioning unit that provides outstanding comfort and performance for residential spaces. Engineered with contemporary technology, this HVAC system showcases a blend of innovative features designed to enhance user experience while promoting energy efficiency.

One of the main features of the Bryant 558J is its high Seasonal Energy Efficiency Ratio (SEER) rating, which ensures optimal energy savings while providing consistent cooling throughout the warmer months. This model boasts an impressive SEER that positions it among the top performers in its category, making it an excellent choice for environmentally-conscious homeowners looking to reduce their energy consumption.

The Bryant 558J utilizes advanced variable-speed compressor technology. This means it can adjust its cooling output dynamically based on indoor temperature requirements, which results in improved temperature consistency and quieter operation. Unlike single-speed systems that can be noisy during operation, the variable-speed compressor provides a more tranquil living environment, as it can run at lower speeds for extended periods.

Additionally, the unit is equipped with a durable, all-weather cabinet designed to resist corrosion and withstand the elements, ensuring longevity and reliability. The unit's aesthetic design also allows it to blend seamlessly into most outdoor settings, enhancing curb appeal without compromising functionality.

In terms of installation and maintenance, the Bryant 558J offers user-friendly features. Its compact design makes it easy to install in tight spaces, while the easy-access panel allows for straightforward maintenance and servicing, reducing downtime and improving overall efficiency.

The unit is compatible with smart thermostats, allowing homeowners to integrate modern technology into their HVAC systems. This compatibility empowers users to control their home environment remotely, monitor energy usage, and create personalized schedules that align with their lifestyles.

Furthermore, the Bryant 558J comes with a comprehensive warranty, offering peace of mind to residents investing in a cooling solution. This level of backing evidences the manufacturer's commitment to quality and customer satisfaction.

In summary, the Bryant 558J stands out as a premier air conditioning solution characterized by its high efficiency, variable-speed technology, durable construction, and modern compatibility. Whether for new installations or replacements, this model exemplifies the perfect balance of comfort, reliability, and energy savings, making it a worthwhile investment for any homeowner.