a. Kit shall provide connectors to permit gas and electrical connections to be brought to the unit through the basepan.

22.Fan/Filter Status Switch:

a.Provides status of indoor (evaporator) fan (ON/ OFF) or filter (CLEAN/DIRTY). Status shall be displayed over communication bus when used with direct digital controls or with an indicator light at the thermostat.

23.Outdoor Air Enthalpy Sensor:

a.The outdoor air enthalpy sensor shall be used to provide single enthalpy control. When used in conjunction with a return air enthalpy sensor, the unit will provide differential enthalpy control. The sensor allows the unit to determine if outside air is suitable for free cooling.

24.Return Air Enthalpy Sensor:

a.The return air enthalpy sensor shall be used in conjunction with an outdoor air enthalpy sensor to provide differential enthalpy control.

25.Indoor Air Quality (CO2) Sensor:

a.Shall be able to provide demand ventilation indoor air quality (IAQ) control.

b.The IAQ sensor shall be available in duct mount, wall mount, or wall mount with LED display. The set point shall have adjustment capability.

26.Hinged Panel Option:

a.Hinged panel option provides hinged access panels for the filter, compressor, evaporator fan, and control box areas.

b.Filter hinged panels permit tool-less entry for changing filters.

c.Each hinged panel is permanently attached to the rooftop unit.

27.Smoke detectors:

a.Shall be a Four-Wire Controller and Detector.

b.Shall be environmental compensated with differential sensing for reliable, stable, and drift-free sensitivity.

c.Shall use magnet-activated test/reset sensor switches.

d.Shall have tool-less connection terminal access.

e.Shall have a recessed momentary switch for testing and resetting the detector.

f.Controller shall include:

i.One set of normally open alarm initiation contacts for connection to an initiating device circuit on a fire alarm control panel

ii.Two Form-C auxiliary alarm relays for interface with rooftop unit or other equipment

iii.One Form-C supervision (trouble) relay to control the operation of the Trouble LED on a remote test/re- set station

iv.Capable of direct connection to two individual detector modules

v.Can be wired to up to 14 other duct smoke detectors for multiple fan shutdown applications

28.Winter start kit

a.Shall contain a bypass device around the low pressure switch.

b.Shall be required when mechanical cooling below an outdoor ambient of 40_F (4_C).

c.Shall not be required to operate an equipped economizer when below an outdoor ambient of 40_F (4_C).

29.Barometric relief

a.Shall include damper, seals, hard-ware, and hoods to relieve excess building pressure.

b.Damper shall gravity-close upon unit shutdown.

30.Time Guard

a.Shall prevent compressor short cycling by providing a 5-minute delay (±2 minutes) before restarting a compressor after shutdown for any reason.

b.One device shall be required per compressor.

558J

E2008 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231

Printed in U.S.A.

Edition Date: 01/08

Catalog No. PDS558J---01

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Replaces: NEW

55

Image 55
Contents Product Data Table of Contents Features and Benefits Voltage Cooling Tons Factory Installed OptionsUnit Type Design RevisionEconomizer Sensors FACTORY-INSTALLED Options and FIELD-INSTALLED AccessoriesEconomizers DampersFactory Options AND/OR Accessories Thru-the-Base Connections Alternate Motors and DrivesElectric Heaters ARI Cooling Rating Tables Unit Cooling Electric Heaters Minimum Maximum Airflows Electric HeatMinimum Outdoor Sound dB Sound Performance Table125 250 500 1000 2000 4000 8000 Tons Physical Data CoolingElectric Heat Electrical Data Tons CRSINGLE***A00 Part Number Power 102A00 6.0 104B00 10.5 9.6 105A00 16.0 12.0/14.7 038 Base Unit Dimensions Chassis Curbs & Weights Dimensions ChassisCurb Installation Detail Typical Application Data Determine cooling and heating loads Selection Procedure with 558J*07 Example558J*04 105 115 EAT dB Ambient Temperature558J*05 105 115 EAT dB 558J*06 105 115 EAT dB 558J*07 105 115 EAT dB TonsGeneral fan performance notes Static Pressure Adders Factory Options and/or Accessories558J*04 FAN PerformanceCFM RPM BHP FAN Performance 558J*05 1512 1494Medium Static Option High Static Option 1485724 558J*06765 2250 980 1066 1146 1220 1291 2375 1024 907 558J*07Unit MOTOR/DRIVE Motor Pulley Turns Open Combo Pulley AdjustmentCfm ECONOMIZER, Barometric Relief and PE PerformanceElectrical Information FLA Type FLA Mocp DISC. Size MCA/MOCP Determination no C.O. or Unpwrd C.OElectric Heater IFM MCA No P.E FLA LRA558J*05 IFM No P.E FLA LRA MCA/MOCP Determination W/ Pwrd C.OType FLA MCA Mocp DISC. Size 15.5 16.5 11.5 Type FLA MCA Mocp DISC. Size LRA IFM No P.EIFM MCA No P.E LRA Unit IFM No P.E PH---HZ Electric Heater40.0 41.3 12.9 13.9 14.4 15.6 Typical Power Diagram Economizer Notes Typical Wiring DiagramElectro-mechanical units with an economizer Sequence of OperationGeneral Electro-mechanical units with no economizerHvac Guide Specifications Guide Specifications 558J*04-0723 09 93.13 Insert Sequence of Operation 558J 558J 558J 558J 558J 558J Catalog No. PDS558J---01

558J specifications

The Bryant 558J is a high-efficiency air conditioning unit that provides outstanding comfort and performance for residential spaces. Engineered with contemporary technology, this HVAC system showcases a blend of innovative features designed to enhance user experience while promoting energy efficiency.

One of the main features of the Bryant 558J is its high Seasonal Energy Efficiency Ratio (SEER) rating, which ensures optimal energy savings while providing consistent cooling throughout the warmer months. This model boasts an impressive SEER that positions it among the top performers in its category, making it an excellent choice for environmentally-conscious homeowners looking to reduce their energy consumption.

The Bryant 558J utilizes advanced variable-speed compressor technology. This means it can adjust its cooling output dynamically based on indoor temperature requirements, which results in improved temperature consistency and quieter operation. Unlike single-speed systems that can be noisy during operation, the variable-speed compressor provides a more tranquil living environment, as it can run at lower speeds for extended periods.

Additionally, the unit is equipped with a durable, all-weather cabinet designed to resist corrosion and withstand the elements, ensuring longevity and reliability. The unit's aesthetic design also allows it to blend seamlessly into most outdoor settings, enhancing curb appeal without compromising functionality.

In terms of installation and maintenance, the Bryant 558J offers user-friendly features. Its compact design makes it easy to install in tight spaces, while the easy-access panel allows for straightforward maintenance and servicing, reducing downtime and improving overall efficiency.

The unit is compatible with smart thermostats, allowing homeowners to integrate modern technology into their HVAC systems. This compatibility empowers users to control their home environment remotely, monitor energy usage, and create personalized schedules that align with their lifestyles.

Furthermore, the Bryant 558J comes with a comprehensive warranty, offering peace of mind to residents investing in a cooling solution. This level of backing evidences the manufacturer's commitment to quality and customer satisfaction.

In summary, the Bryant 558J stands out as a premier air conditioning solution characterized by its high efficiency, variable-speed technology, durable construction, and modern compatibility. Whether for new installations or replacements, this model exemplifies the perfect balance of comfort, reliability, and energy savings, making it a worthwhile investment for any homeowner.