Carrier 19XR installation instructions Copyright 1997 Carrier Corporation

Page 38

Copyright 1997 Carrier Corporation

Manufacturer reserves the right to discontinue, or change at any time, speci®cations or designs without notice and without incurring obligations.

Book

2

 

PC 211

Catalog No. 531-940

Printed in U.S.A.

Form 19XR-2SI

Pg 38

10-97

Replaces: 19XR-1SI

Tab

5a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 38
Contents Installation Instructions Contents Model Number Identication Front TOP View Frame Size Compressor Cooler Maximum VesselChain Length LengthMachine Rigging Guide Cooler Size 70 Through DIM. ``A DIM. ``B DIM. ``CHeat Exchanger SizeFrame 19XR Dimensions Marine Waterbox19XR Nozzle Size English 19XR Compressor Weights19XR Component Weights Code19XR Heat Exchanger Data 19XR Additional Data for Marine Waterboxes Condenser Ð 19XR Waterbox Cover WeightsHeat Waterbox Frame Exchanger Description SI kg Cooler, Side View 19XR Chiller Top View Chiller End View 20-22 Dimensions ft-in15-17 30-32Standard Isolation Typical Nozzle Piping COM Ð CommonPiping Flow Data NIH, Frames 1 Through Frames 1, 2, Frames 4, 5,Condenser Waterboxes OutCode Marine Waterboxes Frames 2Out Arrangement Piping Flow Data MWB, Frames 4 Through Marine Waterboxes Frames 4, 5,Nominal Pipe Size Actual Pipe ID 19XR Waterbox Nozzle SizesFrame Pressure Pass Psig kPa Cooler Condenser0452 Tank Size0428 QTY Trade Size LocationMaximum Refrigerant Capacity lb Weight Size ANSI/ASHRAETank Tank OD DRY Maximum Refrigerant Capacity kgOptional Pumpout System Piping Schematic with Storage Tank Quantity Relief Valve ConnectorRelief Device Locations Outlet SizeCarrier Comfort Network Communication Bus Wiring 19XR with Optional Unit-Mounted Starter 19XR with Free-Standing Starter RLA 19XR Typical Field Wiring with Free-Standing Starter Manufacturer Cable no Install Field Insulation Page Page Copyright 1997 Carrier Corporation Installation START-UP Request Checklist Testing YES/NO Date to be Completed
Related manuals
Manual 140 pages 13.24 Kb

19XR specifications

The Carrier 19XR and 19XRV chillers are sophisticated cooling solutions that represent the forefront of HVAC technology. Designed for large commercial and industrial applications, these chillers provide exceptional performance, energy efficiency, and reliability, making them ideal for a variety of environments ranging from hospitals to manufacturing facilities.

One of the most significant features of the Carrier 19XR and 19XRV chillers is their advanced scroll compressor technology. These units employ a tandem scroll design that enhances efficiency while minimizing operational noise. This makes them ideal for urban environments where noise restrictions may be in place. Moreover, the compressors are equipped with variable speed drive options in the 19XRV model, which allows for greater energy savings by adjusting cooling output based on real-time demand.

In addition to their advanced compressors, the 19XR and 19XRV units incorporate the Carrier GreenChoice refrigerant, which has a lower global warming potential compared to traditional refrigerants. This innovative choice not only meets regulatory requirements but also contributes to sustainability goals, making these chillers a responsible choice for environmentally conscious organizations.

The units are engineered with a robust heat exchanger design, which enhances heat transfer efficiency and overall system performance. This ensures optimal operation even in extreme conditions. They feature a microprocessor-based control system that allows for precise monitoring and control of the chiller’s performance, enabling operators to make real-time adjustments to maximize energy efficiency.

The Carrier 19XR and 19XRV chillers also prioritize serviceability. The design incorporates easy access to key components, simplifying maintenance procedures and reducing downtime. This focus on maintainability extends the lifespan of the equipment, leading to lower lifecycle costs.

In terms of connectivity, these chillers are equipped with advanced Building Management System (BMS) integration capabilities. This allows for seamless monitoring and control of the chillers using a centralized platform, facilitating energy management and operational optimization.

Overall, the Carrier 19XR and 19XRV chillers stand out in the market for their blend of cutting-edge technology, energy efficiency, and user-friendly features. They are engineered to meet the demanding needs of modern commercial and industrial applications, making them a preferred choice for facility managers seeking reliable cooling solutions.